SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. 

That's your signal to go into immediate action!

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precau-

tions which can protect both you and your family from an 

accident. Read them carefully now, then review them point 

by point with the members of your household. Someday when 

there may not be a minute to lose, everyone's safety will depend 

on knowing exactly what to do. If, after reading the following 

information, you feel you still need more information, please 

contact your gas supplier.

•  Do not operate electric switches, light matches, use your phone. 

Do not do anything that could ignite the gas.

•  Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•  Close all gas tank or cylinder supply valves.

•  LP-Gas is heavier than air and may settle in low areas such as 

basements. When you have reason to suspect a gas leak, keep 

out of basements and other low areas. Stay out until firefighters 

declare them to be safe.

•  Use your neighbor's phone and call a trained LP-Gas service 

person and the fire department. Even though you may not con-

tinue to smell gas, do not turn on the gas again. Do not re-enter 

the building, vehicle, trailer, or area.

  Finally, 

let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then check 

and relight the gas appliance for you.

Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you 

can smell the odorant in propane.

 Smoking can decrease your 

ability to smell. Being around an odor for a time can affect your 

sensitivity or ability to detect that odor. Sometimes other odors 

in the area mask the gas odor. People may not smell the gas odor 

or their minds are on something else. Thinking about smelling a 

gas odor can make it easier to smell.

The odorant in LP-gas is colorless, and it can fade under some 

circumstances.

 For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants 

in LP-Gas also are subject to oxidation. This fading can occur if 

there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, 

masonry and other materials and fabrics in a room. That will take 

some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

• 

Learn to recognize the odor of LP-gas.

 Your local LP-Gas 

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

•  If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

•  Sometimes a basement or a closed-up house has a musty smell 

that can cover up the LP-Gas odor. Do not try to light pilot 

lights, perform service, or make adjustments in an area where 

the conditions are such that you may not detect the odor if there 

has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been out 

of service for a time may develop internal rust which will cause 

odor fade. If such conditions are suspected to exist, a periodic 

sniff test of the gas is advisable. 

If you have any question about 

the gas odor, call your LP-gas dealer. A periodic sniff test of 

the LP-gas is a good safety measure under any condition.

•  If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

•  If you experience a complete "gas out," (the container is under 

no vapor pressure), turn the tank valve off immediately. If the 

container valve is left on, the container may draw in some air 

through openings such as pilot light orifices. If this occurs, some 

new internal rusting could occur. If the valve is left open, then 

treat the container as a new tank. Always be sure your container 

is under vapor pressure by turning it off at the container before 

it goes completely empty or having it refilled before it is com-

pletely empty.

SAFETY INFORMATION FOR USERS OF LP-GAS

Summary of Contents for VFP30CA30BN-1

Page 1: ...manentlylocated manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use...

Page 2: ...LOG PLACEMENT 11 OPERATING GUIDELINES 12 LIGHTING INSTRUCTIONS 13 PILOT FLAME CHARACTERISTICS 14 MAIN BURNER FLAME CHARACTERISTICS 15 WIRING 16 17 MAINTENANCE 17 TROUBLESHOOTING 18 19 HOW TO ORDER RE...

Page 3: ...and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same...

Page 4: ...sorborabsorbontoorintowalls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the...

Page 5: ...r your gas company before changing spud ori ce size AlwaysconsultyourlocalBuildingDepartmentregardingregulations codes or ordinances which apply to the installation of an unvented room heater This app...

Page 6: ...e air 3 Do not use an unvented room heater as the primary heat source an entire house WATER VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Model VFP30CA30 B F M S W Input BTU HR KW H Maximum 32 000 9 4 B...

Page 7: ...et in width and 8 feet in height the area is 1 632 cubic feet The VFP30 can be installed in this uncon ned space with no requirement to provide additional combustion and ventilation air PROVISIONS FOR...

Page 8: ...th Schedule 40 Pipe Inside Diameter Tubing Type L Outside Diameter Nat L P Nat L P 0 10 feet 0 3 meters 1 2 12 7 mm 3 8 9 5 mm 1 2 12 7 mm 3 8 9 5 mm 10 40 feet 4 12 meters 1 2 12 7 mm 1 2 12 7 mm 5 8...

Page 9: ...vicing and proper operation must be provided Installation on Rugs and Tile Thisappliancemustbeinstalledona at solid continuoussurface e g wood metal concrete This may be the oor or it may be raised up...

Page 10: ...r shutter 9 Tighten the two 2 nuts back down locking the air shutter in place Be sure that the air shutter is the same distance from the burner ori ce on both sides of the air shutter for proper burne...

Page 11: ...th toe resting on the groove in the left front log 12 Place right twig onto right side pin on rear log with toe resting all the way to the right on the right front log 13 Align and place top of glass...

Page 12: ...ter please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below 1 Know what type of ignition system this model has standing pilot and follow...

Page 13: ...r If you smell gas STOP Fol low B in the safety information above on this plate If you do not smell gas go to the next Step 7 Find pilot The pilot is attached to the main burner behind the front log 8...

Page 14: ...ools the heater will shut down Correct Pilot Flame Pattern Figure 11 Incorrect Pilot Flame Pattern Figure 12 If pilot ame pattern is incorrect as shown in Figure 12 See Troubleshooting pages 18 and 19...

Page 15: ...should clean dust lint and any light accumulation from the logs and the rebox area An extra soft brush should be used on the logs and burner as they are extremely fragile a vacuum cleaner may be used...

Page 16: ...er that is a component in the FREC Turn the ON OFF REMOTE switch on the wire channel to the REMOTE position Follow instructions in the FREC to complete installation Note If electric 120 volt fails in...

Page 17: ...shown for proper main burner ame pattern Figure 14 If it appears abnormal call a service person Verify proper operation after servicing MAINTENANCE Figure 18 WIRING continued Figure 17 REMOTE OFF ON S...

Page 18: ...a Main burner ori ce clogged Clean main burner or replace main burner ori ce b Main burner ori ce diameter is too small Replace main burner ori ce c Inlet gas pressure is too low Contact local gas co...

Page 19: ...s a Not enough fresh air is available Open window and or door for ventilation b Low line pressure Contact local gas company c ODS pilot is partially clogged Clean ODS pilot 14 Gas odor even when contr...

Page 20: ...84 ORIFICE 35 NAT 13 P 250 ORIFICE 1 65mm LPG 14 24215 AIR SHUTTER BRACKET NAT 14 24430 AIR SHUTTER BRACKET LPG 15 24041 FIREBOX BOTTOM 16 15977 VALVE BRACKET 17 24024 TUBING ASSEMBLY VALVE TO BURNER...

Page 21: ...24214 2 1008 Page 21 PARTS VIEW 26 27 28 29 30 31 1 3 4 5 6 7 8 9 10 32 33 34 2 7 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 35...

Page 22: ...4 R 9568 CASTING TOP 5 R 9681 CASTING FRONT 6 R 9567 CASTING SIDE RIGHT 7 R 9566 CASTING SIDE LEFT 8 R 9683 CASTING DOOR RIGHT 9 R 9682 CASTING DOOR LEFT 10 24191 FIREBOX SUPPORT BRACKET 2 REQUIRED 1...

Page 23: ...24214 2 1008 Page 23 2 3 9 4 5 6 7 8 10 10 1 11 11 11 11 13 12 12 13 CASTING PARTS VIEW...

Page 24: ...to remove side shelf supports prior to removing cast iron top to eliminate potential scratching or chipping to the cast iron sides Note Due to inherent properties of the casting process non com busti...

Page 25: ...allow fan control bracket to slide into slot 6 Route fan control wires through rectangular notch on wire channel left 7 Attach 1 4 push on terminal from blue wire on the fan control to the AUTO top t...

Page 26: ...external electrical source is utilized This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded thr...

Page 27: ...DEX NUMBER PART NUMBER DESCRIPTION 1 R 1454 BRASS BUSHING 2 R 1499 RUBBER GROMMET 3 24231 BLOWER HOUSING 4 R 1410 STRAIN RELIEF BUSHING 5 R 9927 BLOWER ASSEMBLY 6 24225 BLOWER COVER 7 R 6159 CORD SET...

Page 28: ...24214 2 1008 Page 28 SERVICE NOTES...

Page 29: ...24214 2 1008 Page 29 SERVICE NOTES...

Page 30: ...24214 2 1008 Page 30 SERVICE NOTES...

Page 31: ...ance the following minimum clearances to combustible construction must be maintained Top of appliance ceiling 36 inches Heater Corners 45 angle to Wall 4 inches Rear Wall 2 inches Floor 0 inches Side...

Page 32: ...Page 32 EMPIRE EMPIRE Comfort Systems Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empir...

Reviews: