24214-2-1008
Page 31
Web Site: www.empirecomfort.com
The Heritage Cast Iron Stoves
Models:
VFP30CA30B, VFP30CA30F, VFP30CA30M, VFP30CA30S,
VFP30CA30W
Empire Comfort Systems
918 Freeburg Avenue
Belleville, Illinois 62220-2623
GAS-FIRED
EMPIRE
EMPIRE
Comfort Systems
Specifications
Model
VFP30CA30(B,F,M,S,W)
Input BTU/HR (KW/H) Maximum
32,000 (9.4)
BTU/HR (KW/H) Minimum
22,400 (6.6)
Height
27 3/4" (704.9 mm)
Width
28 1/16" (712.8 mm)
Depth
17 1/8" (435.0 mm)
Gas Inlet (Pipe)
3/8" (9.5 mm)
Clearances
In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper opera-
tion.
Locating the Vent Free Cast Iron Stove
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Top of appliance (ceiling) 36 inches
Heater Corners (45° angle) to Wall 4 inches
Rear Wall
2 inches
Floor
0 inches
Side Wall
6 inches
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
Installation on Rugs and Tile
This appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or it may
be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, vinyl, wood flooring or other
combustible material.
6” (153mm) TO SIDE WALL
OR COMBUSTIBLE
MATERIAL
36” (91cm) TO CEILING OR
HORIZONTAL PROJECTION
ABOVE APPLIANCE
NOTE: HEATER INSTALLED AT
45° ANGLE IN CORNER
4” (102mm) HEATER CORNERS
TO SIDE WALL
4”
(102mm)
2” (51mm) TO COMBUSTIBLE MATERIAL