![Empire Comfort Systems VFNI-24N-1 Owner'S Manual Download Page 16](http://html1.mh-extra.com/html/empire-comfort-systems/vfni-24n-1/vfni-24n-1_owners-manual_2403911016.webp)
28091-8-0814
Page 16
Placing Lava Rock in Front of Burner on Fireplace Floor
Spread lava rocks on fireplace floor in front of the burner pan. The
lava rocks are for decorative effect and are not required for fireplace
operation.
ATTENTION:
DO NOT PLACE LAVA ROCKS ON
BURNER, LOGS OR ROCK WOOL. THE LAVA ROCKS
SHOULD ONLY BE PLACED ON THE FIREPLACE FLOOR.
Flames from the pilot (rear right back side of the pan burner) as
well as the main flame should be visually checked as the log set
is installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.
Notice:
All flames will be random by design, flame height will go
up and down.
Glowing embers (rock wool) can cover the pan burner in between
the front and middle logs, but very little is necessary to cover this
area. Excess ember material causes the yellow flame to become
orange and stringy. Apply just enough to obtain slow glow and a
gold yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow fans to
blow directly into fireplace. Do not place a blower inside the burner
area of the firebox. Ceiling fans may create drafts that alter flame
patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components
of this appliance are treated with certain oils, films or bonding agents.
These chemicals are not harmful, but may produce annoying smoke
and smells as they are burned off during the initial operation of the
appliance, possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
Variable - Figure 13
Millivolt - Figure 14
IP - Figure 15
Placement of the glowing embers (rock wool) is very individual
and light coverage will provide your best effects. We recommend
separation of the rock wool by hand and make your coverage as
light and fluffy as possible.
Place just enough embers on the burner to obtain the glow and a
gold, yellow flame.
Do not place embers (rock wool) over large ports on any portion
of burner.
Rock wool should not be placed in the area of the pilot assembly.
Replacement of loose material (glowing embers) must be purchased
from Empire Comfort Systems, Inc. Application of excess loose
material (glowing embers) may adversely affect performance of
the heater.
WARNING:
All previously applied loose material must be
removed prior to reapplication.
Refer to Parts List, Page 31 to order loose material (rock wool).
PLACEMENT OF GLOWING EMBERS AND LAVA ROCK
OPERATION INSTRUCTIONS/FLAME APPEARANCE