FIREPLACE DIMENSIONS
Figure 1
When planning a fireplace insert installation, it’s necessary to
determine:
•
Gas supply piping (left side entrance).
•
Electrical connections - for optional light kit
•
Electrical supply requirements for optional light.
(120V, 60Hz, 1 Amp) (right side entrance)
•
Proper opening size of fireplace required for installation of
the fireplace insert.
VF FIREPLACE DIMENSIONS (in inches)
MODEL
A
B
C
D
E
F
G
H
I
J
K
L
M
VFLL38FP 43-1/4
35
12-1/16 38-1/4
41-5/8 11-15/32
1/2
10-15/16
15/16
21-1/8
13
7-7/16 12-1/8
VFLL48FP 52-3/4
35
12-1/16
48
51-3/8 11-15/32
1/2
10-15/16
15/16
21-1/8
13
7-7/16 12-1/8
UNPACKING THE FIREPLACE
1. Cut binding straps and shrink wrap.
2. Remove top of carton.
3. Remove glass carton from back of unit and set aside.
4. Remove non-combustible board and set aside.
5. Remove remaining carton.
6. Verify that the fireplace and components have not been dam
-
aged during shipping.
7. Set fireplace in a location near to its final installation location.
In planning the installation for the fireplace, determine where the
unit is to be installed and whether optional accessories are desired.
Gas supply piping should also be planned at this time.
The fireplace can be mounted on any of these surfaces:
1. A flat hard combustible or non-combustible surface.
2. A raised platform of combustible or non-combustible material.
3. Four corners of the fireplace so contact is made on all four
perimeter edges on the bottom of the unit.
If the fireplace is installed directly on carpeting, tile or other
combustible material other than wood flooring, it should be installed
on a metal or wood panel extending the full width and depth of the
unit.
This unit is designed to be installed in a zero-clearance enclosure.
This means the combustible material can come in contact with the
top and side standoff spacers, and secured to combustible framing
using the framing brackets provided.