background image

32272-0-0713

Page 3

• 

Installer: please leave these instructions with the owner for 

future reference

• 

This unit complies with ANSI Z21.97/CSA 2.41 and CSA 4.96 

U.S. for Outdoor Gas Fireplaces.

• 

Children and adults should be alerted to the hazard of high 

surface temperature and should stay away to avoid burns 

or clothing ignition.

• 

Young children should be carefully supervised when they 

are in the same area with the appliance.

• 

Clothing or other flammable materials should not be hung 

from the appliance, or placed on or near the appliance.

• 

Installation and repair should be done by a QUALIFIED 

SERVICE pERSON.  This appliance should be inspected 

before use and at least annually by a professional service 

person.  More frequent cleaning may be required due to 

insects, pollen build up, dust, etc.  It is imperative that 

the control compartments, burners, and circulating air 

passageways of the appliance be kept clean.

• 

Do not place trash, logs, or other articles on the log set 

during operation.

• 

During manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain oils, 

films or bonding agents.  These agents are not harmful, but 

may produce annoying smoke and smells as they are burned 

off during initial operation of the appliance.  This is a normal 

temporary occurrence. 

• 

WARNING: Keep appliance area clear and free from 

combustible materials, gasoline and other flammable vapors 

and liquids.

• 

WARNING: Any modification to this gas log set or to controls 

can be dangerous.  Improper installation or use of the gas 

log set can cause serious injury or death from fire, burns, 

explosion or carbon monoxide poisoning.

• 

Follow all local codes regarding installation, combustion 

and ventilation air or in the absence of local codes follow 

the National Fuel Gas Code ANSI Z223.1 (US installation), or 

CAN/CGA-B149, installation Code (Canada installation).

• 

Do not operate this log set with glass doors in the closed 

position. A fireplace screen must be in place when the log 

set is burning.

• 

Inspect the hose before each use of the appliance. 

• 

The hose assembly must be replaced prior to the ap-

pliance being into operation if there is evidence of ex-

cessive abrasion or wear, or if the hose is damaged. 

• 

Inspect the burner at least once a year.

IMpORTANT SAFETY INFORMATION

DO NOT OpERATE THIS GAS LOG SET WITH GLASS DOORS CLOSED.

DANGER

: Indicates a hazardous situation which, if not 

avoided, will result in death or serious injury. 

WARNING

: Indicates a hazardous situation which, if 

not avoided, could result in death or serious injury.

CAUTION

: Indicates a hazardous situation which, if not 

avoided, could result in minor or moderate injury.

NOTICE

: Addresses practices not related to personal in-

jury.

•  Children and adults should be alerted to the hazards of 

high surface temperatures and should stay away to avoid 

burns or clothing ignition.

•  Young children should be carefully supervised when they 

are in the same area as the appliance.

•  Clothing or other flammable material should not be placed 

on or near the appliance.

• 

Do not place trash or other articles on the log set during 

operation.

•  During manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain oils, 

films or bonding agents. These bonding agents are not 

harmful but may produce annoying smoke and smells as 

they are burned off during initial operation of the appliance. 

This is a normal temporary occurrence.  

•  Keep burner and control compartment clean. 

• 

Installation and repair should be done by a QUALIFIED 

SERVICE pERSON. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, etc. It 

is imperative that control compartments, burners and 

circulating air passageways of the appliance be kept 

clean.

•  Do

 keep the appliance area clear and free from combustible 

material,  gasoline  and  other  flammable  vapors  and 

liquids.

• 

A yearly examination and cleaning of the venting system 

of the solid-fuel burning fireplace must be performed by 

a qualified agency.

•  Do 

make a periodic visual check of pilot and burners. 

Clean and replace damaged parts.

•  Do NoT 

use this appliance if any part has been under 

water.  Immediately  call  a  qualified  service  technician 

to inspect the appliance and to replace any part of the 

control system and any gas control which has been under 

water. 

Summary of Contents for OP36FP32MN-2

Page 1: ... plier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If the information in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WA...

Page 2: ...Fireplace Framing and Installation 13 Gas Line Connection 13 Operation Instructions Flame Appearance 13 OP 36 42 FP72 Lighting Instructions 14 OP 36 42 FP32 Lighting Instructions 15 Pilot and Main Burner Flame Characteristics 16 Wiring 16 17 Remote Control Installation Operation 18 Maintenance 19 Troubleshooting 19 Parts List 20 21 Parts View 22 Master Parts Distributor List 23 How To Order Repair...

Page 3: ... to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION Do Not Operate THIS Gas Log Set With Glass Doors Closed DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoid...

Page 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you detect any odor ...

Page 5: ...NG Thisapplianceisequippedfor naturalgasorpropane gas Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with this fireplace 3 Installer should show owner how to start and operate unvented room heater AlwaysconsultyourlocalBuildingDepartment regardin...

Page 6: ...f the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equally sized spaced at 180 degrees 3 14rad and unob structed Each opening shall have a total free area of not less than 1 2 square inch per pound 2 3 sq cm kg of stored fuel capacity and not less than a t...

Page 7: ...ual main gas cock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be checked for leaks by the installer This should be done with a soap so...

Page 8: ...ireplace models must use the hood supplied with the fireplace If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 2 Figure 2 Mantel Clearances CLEARANCES Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 3 No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplac...

Page 9: ...CE LETTER OP36FP OP42FP A 41 7 8 41 7 8 B 41 5 8 43 1 8 C 19 1 4 19 1 4 D 32 1 4 36 1 4 E 34 7 8 34 7 8 F 36 40 G 24 24 H 6 3 8 6 3 8 I 30 3 8 30 3 8 J 8 3 8 8 3 8 K 5 1 4 5 1 4 L 37 5 8 39 5 8 M 75 3 8 79 1 4 N 2 11 16 2 11 16 O 8 1 8 8 1 8 O N C J K G I A H F B D L M E ...

Page 10: ...han a safety issues Typical installation may include covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 92 inches Outdoor Fireplace Enclosure Requirements Do not install appliance until all necessary provisions are made for combustion and ventilation air Consult the written instructions provided with the appliance for informat...

Page 11: ...idic applications such as mortar or stone etching do not remove the protective PVC film from the stainless steel until after this application is complete Once the film has been removed we recommend that the appli ance be cleaned with a stainless steel cleaner immediately FIREPLACE FRAMING AND INSTALLATION Locate the three metal framing studs SIDE TOP OP36FP Two 42 Stud One 41 5 8 Stud OP42FP Two 4...

Page 12: ...a pan head screw through the middle bracket and into the top stud 5 Locate the two non combustible boards and place them above the fireplace as shown in Figure 11 Attach the non combustible board to the studs with six 10 16 flathead screws 6 Secure the non combustible board to the middle bracket using two 10 16 flathead screws as shown in Figure 11 7 Move the fireplace into position Connect the ga...

Page 13: ...er operation OPERATION INSTRUCTIONS FLAME APPEARANCE Millivolt Figure 15 Figure 13 GAS LINE CONNECTION Figure 14 GAS ACCESS HOLES The fireplace is designed to accept a 3 8 inch gas line for an approved ventless gas logset Have the line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 i...

Page 14: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise to OFF Do not force 1 STOP Read the safety information above 2 Turn gas cock counterclockwise to ON position 3 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If...

Page 15: ...This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in y...

Page 16: ...valve does not require 110 volts Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all optional switches Use the two leads Red and Green to attach optional components Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range WIRING Pilot Flame Pattern Figure 16 If pilot flame pattern is incorrec...

Page 17: ...Learn MOTOR COMM POWER IPI Continuous Pilot Off On Remote Off S I ADJ GND HI LO Solenoid ORANGE IGNITOR BLACK SENSOR BLACK ORANGE GREEN WHITE BROWN PILOT GAS CONTROL VALVE ELECTRONIC CONTROL MODULE N A AF 4000 B P RED BLACK BLACK BROWN RED ORANGE N A Figure 18 ...

Page 18: ...al use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on the module is in the REMOTE position the module will NOT LEARN if the slide switch is in the OFF position Press and release the LEARN button on the module to accept the transmitter security code and...

Page 19: ...rn control knob to Pilot position c Control knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat igniting operation until air is removed e Pilot is clogged Replace pilot assembly or get it serviced f Gas regulator setting is not correct Replace gas regulator 7 Pilot lights but flame goes out wh...

Page 20: ... 20237 Hood 13 R11036 R11036 R11037 R11037 Curtain Rod 14 R10765 R10765 R10765 R10765 Curtain Screen 15 27934 27934 27935 27935 Rear Log Support 16 27930 27930 27930 27930 Burner Support Left 17 27932 27932 27932 27932 Burner Support Right 18 27799 27799 27801 27801 Grate Tang Assembly 19 P253 P253 P253 P253 Orifice Fitting 20 P280 P280 P280 P280 Orifice Nat 20 P245 P245 P300 P300 Orifice LP 21 R1...

Page 21: ...8 27800 28088 27800 Ignitor Bracket 35 28081 28081 Valve Bracket 36 31514 31514 Water Shield 37 32231 32231 32331 32231 Metal Channel Side 38 32233 32233 32234 32234 Metal Channel Top 39 R11681 R11681 R11683 R11683 Non Combustible Board 40 10554 10554 10554 10554 Flanges 41 R10072 R10072 R10072 R10072 Shut Off Valve NS 28748 28748 28748 28748 Gas Line Cover NS R10815 R10815 Remote Control NS Not S...

Page 22: ...32272 0 0713 Page 22 PARTS VIEW 29 31 30 10 8 6 5 1 12 2 13 13 14 37 8 9 11 7 4 33 36 35 18 21 20 19 16 22 28 15 17 25 34 15 16 23 17 26 27 22 28 34 21 20 19 25 18 24 32 37 1 38 39 3 41 42 40 40 ...

Page 23: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Nu...

Page 24: ...ner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this ap...