INTRODUCTION

• 

When the appliance is connected to a fixed piping system, 

the installation must conform with local codes, or in the ab-

sence of local codes with the 

National Fuel Gas Code, ANSI 

Z223.1/NFPA 54

, or 

International Fuel Gas Code

.

• 

When installed, the appliance must be electrically grounded 

in accordance with local codes, or in the absence of local 

codes with the 

National Electrical Code, ANSI/NFPA 70

, if 

applicable.

• 

Solid fuels shall not be burned in this appliance.

• 

The maximum gas inlet supply pressure is 13" for LP and 

10.5" for NAT.

• 

For appliances for fixed fuel piping system and equipped 

with an appliance gas pressure regulator, the required mani

-

fold pressure in inches water column: 10" for LP and 3.5" 

NAT.

• 

For appliances for fixed fuel piping system and equipped 

with an appliance gas pressure regulator, the appliance and 

its individual shutoff valve must be disconnected from the 

gas supply piping system during any pressure testing of that 

system at test pressures in excess of 1/2 psi (3.5 kPa).

 

The appliance must be isolated from the gas supply piping 

system by closing its individual manual shutoff valve during 

any pressure testing of the gas supply piping system at test 

pressures equal to or less than 1/2 psi (3.5 kPa).

For an appliance designed for use with a non-disposable self-

contained LP-gas supply system:

• 

Propane cylinders may be acceptable for use with the ap-

pliance provided they are compatible with the appliance 

retention means. 

• 

LP-gas supply cylinder must be constructed and marked 

in accordance with the 

U.S. Department of Transportation 

(D.O.T.) Specifications for LP-Gas Cylinders

, or the 

Stan

-

dard for Cylinders, Spheres and Tubes for Transportation 

of Dangerous Goods and Commission, CAN/CSA-B339

 as 

applicable. 

• 

LP-gas supply cylinders between 4 and 40 pounds must 

have an overfill prevention device.

• 

LP-gas supply cylinder must have a connection device com-

patible with the connection of the appliance.

• 

If the appliance is equipped with a CGA No. 600 Cylinder 

Connection Device, the cylinder must be disconnected when 

the appliance is not in use.

• 

If appliance is to be permanently connected to a gas piping 

system from a remote supply tank, installation must be in ac

-

cordance with local codes or, in the absence of local codes, 

with the 

National Fuel Gas Codes ANSI Z223.1/NFPA 54.

Enclosures for LP-gas supply cylinders shall be ventilated by 

openings at the level of the cylinder valve and at floor level. The 

effectiveness of the opening(s) for purposes of ventilation shall 

be determined with the LP-gas supply cylinder(s) in place. This 

shall be accomplished by one of the following.

a.  One side of the enclosure shall be completely open; or

b.  For an enclosure having four sides, a top and a bottom:

1.  At least two ventilation openings at cylinder valve 

level shall be provided in the side wall, equally 

sized, spaced at 180 degrees (3.14rad), and unob-

structed. Each opening shall have a total free area 

of not less than 1/2 square inch per pound (2.3 sq. 

cm/kg) of stored fuel capacity and not less than a 

total free area of 10 square inches (64.5 sq. cm).

2.  Ventilation opening(s) shall be provided at floor 

level and shall have a total free area of not less 

than 1/2 square inch per pound (3.2 sq. cm/kg) of 

stored fuel capacity and not less than a total free 

area of 10 square inches (64.5 sq. cm). If ventila

-

tion openings at floor level are in a side all, there 

shall be at least two openings. The bottom of the 

openings shall be at floor level and the upper edge 

no more than 5 inches (127 mm) above the floor. 

The openings shall be equally sized, spaced at 180 

degrees (3.14 rad) and unobstructed.

3.  Every opening shall have minimum dimensions so 

as to permit the entrance of a 1/8 inch (3.2 mm) 

diameter rod.

• 

Cylinder valves shall be readily accessible for hand opera-

tion. A door on the enclosure to gain access to the cylinder 

valves is acceptable, provided it is non-locking and can be 

opened without the use of tools.

• 

There shall be a minimum clearance of 2 inches (51 mm) 

between the lower surface of the floor of the LP-gas supply 

cylinder enclosure and the ground.

• 

The design of the appliance shall be such that (1) the LP-gas 

supply cylinder(s) can be connected, disconnected and the 

connections inspected and tested outside the cylinder en-

closure; and (2) those connections which could be disturbed 

when installing the cylinder(s) in the enclosure can be leak 

tested inside the enclosure;

Cleaning Instructions

This appliance is built using mostly high-grade stainless steel to 

resist rust-through. In outdoor applications, all stainless steel will 

develop a dull patina and, depending on the local environment 

and on the materials used in the installation, may develop some 

surface oxidation (rust). This does not affect the performance of 

the fireplace, and does not require any action to correct. If you 

prefer keeping your fireplace front looking factory-fresh, clean it 

as required with stainless steel cleaner.

When installation application includes highly acidic applications 

such as mortar or stone etching, do not remove the protective 

PVC film from the stainless steel until after this application is 

complete. Once the film has been removed we recommend that 

the appliance be cleaned with a stainless steel cleaner immedi-

ately.

Please note that areas where the film has been formed (corners, 

hems, etc.) may require extra cleaning due to the properties of 

the film. Ensure that all protective film has been removed from 

the fireplace prior to burning the appliance.  

Summary of Contents for OP36FP32MN-2

Page 1: ... plier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If the information in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WA...

Page 2: ...Fireplace Framing and Installation 13 Gas Line Connection 13 Operation Instructions Flame Appearance 13 OP 36 42 FP72 Lighting Instructions 14 OP 36 42 FP32 Lighting Instructions 15 Pilot and Main Burner Flame Characteristics 16 Wiring 16 17 Remote Control Installation Operation 18 Maintenance 19 Troubleshooting 19 Parts List 20 21 Parts View 22 Master Parts Distributor List 23 How To Order Repair...

Page 3: ... to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION Do Not Operate THIS Gas Log Set With Glass Doors Closed DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoid...

Page 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you detect any odor ...

Page 5: ...NG Thisapplianceisequippedfor naturalgasorpropane gas Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with this fireplace 3 Installer should show owner how to start and operate unvented room heater AlwaysconsultyourlocalBuildingDepartment regardin...

Page 6: ...f the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equally sized spaced at 180 degrees 3 14rad and unob structed Each opening shall have a total free area of not less than 1 2 square inch per pound 2 3 sq cm kg of stored fuel capacity and not less than a t...

Page 7: ...ual main gas cock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be checked for leaks by the installer This should be done with a soap so...

Page 8: ...ireplace models must use the hood supplied with the fireplace If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 2 Figure 2 Mantel Clearances CLEARANCES Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 3 No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplac...

Page 9: ...CE LETTER OP36FP OP42FP A 41 7 8 41 7 8 B 41 5 8 43 1 8 C 19 1 4 19 1 4 D 32 1 4 36 1 4 E 34 7 8 34 7 8 F 36 40 G 24 24 H 6 3 8 6 3 8 I 30 3 8 30 3 8 J 8 3 8 8 3 8 K 5 1 4 5 1 4 L 37 5 8 39 5 8 M 75 3 8 79 1 4 N 2 11 16 2 11 16 O 8 1 8 8 1 8 O N C J K G I A H F B D L M E ...

Page 10: ...han a safety issues Typical installation may include covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 92 inches Outdoor Fireplace Enclosure Requirements Do not install appliance until all necessary provisions are made for combustion and ventilation air Consult the written instructions provided with the appliance for informat...

Page 11: ...idic applications such as mortar or stone etching do not remove the protective PVC film from the stainless steel until after this application is complete Once the film has been removed we recommend that the appli ance be cleaned with a stainless steel cleaner immediately FIREPLACE FRAMING AND INSTALLATION Locate the three metal framing studs SIDE TOP OP36FP Two 42 Stud One 41 5 8 Stud OP42FP Two 4...

Page 12: ...a pan head screw through the middle bracket and into the top stud 5 Locate the two non combustible boards and place them above the fireplace as shown in Figure 11 Attach the non combustible board to the studs with six 10 16 flathead screws 6 Secure the non combustible board to the middle bracket using two 10 16 flathead screws as shown in Figure 11 7 Move the fireplace into position Connect the ga...

Page 13: ...er operation OPERATION INSTRUCTIONS FLAME APPEARANCE Millivolt Figure 15 Figure 13 GAS LINE CONNECTION Figure 14 GAS ACCESS HOLES The fireplace is designed to accept a 3 8 inch gas line for an approved ventless gas logset Have the line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 i...

Page 14: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise to OFF Do not force 1 STOP Read the safety information above 2 Turn gas cock counterclockwise to ON position 3 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If...

Page 15: ...This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in y...

Page 16: ...valve does not require 110 volts Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all optional switches Use the two leads Red and Green to attach optional components Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range WIRING Pilot Flame Pattern Figure 16 If pilot flame pattern is incorrec...

Page 17: ...Learn MOTOR COMM POWER IPI Continuous Pilot Off On Remote Off S I ADJ GND HI LO Solenoid ORANGE IGNITOR BLACK SENSOR BLACK ORANGE GREEN WHITE BROWN PILOT GAS CONTROL VALVE ELECTRONIC CONTROL MODULE N A AF 4000 B P RED BLACK BLACK BROWN RED ORANGE N A Figure 18 ...

Page 18: ...al use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on the module is in the REMOTE position the module will NOT LEARN if the slide switch is in the OFF position Press and release the LEARN button on the module to accept the transmitter security code and...

Page 19: ...rn control knob to Pilot position c Control knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat igniting operation until air is removed e Pilot is clogged Replace pilot assembly or get it serviced f Gas regulator setting is not correct Replace gas regulator 7 Pilot lights but flame goes out wh...

Page 20: ... 20237 Hood 13 R11036 R11036 R11037 R11037 Curtain Rod 14 R10765 R10765 R10765 R10765 Curtain Screen 15 27934 27934 27935 27935 Rear Log Support 16 27930 27930 27930 27930 Burner Support Left 17 27932 27932 27932 27932 Burner Support Right 18 27799 27799 27801 27801 Grate Tang Assembly 19 P253 P253 P253 P253 Orifice Fitting 20 P280 P280 P280 P280 Orifice Nat 20 P245 P245 P300 P300 Orifice LP 21 R1...

Page 21: ...8 27800 28088 27800 Ignitor Bracket 35 28081 28081 Valve Bracket 36 31514 31514 Water Shield 37 32231 32231 32331 32231 Metal Channel Side 38 32233 32233 32234 32234 Metal Channel Top 39 R11681 R11681 R11683 R11683 Non Combustible Board 40 10554 10554 10554 10554 Flanges 41 R10072 R10072 R10072 R10072 Shut Off Valve NS 28748 28748 28748 28748 Gas Line Cover NS R10815 R10815 Remote Control NS Not S...

Page 22: ...32272 0 0713 Page 22 PARTS VIEW 29 31 30 10 8 6 5 1 12 2 13 13 14 37 8 9 11 7 4 33 36 35 18 21 20 19 16 22 28 15 17 25 34 15 16 23 17 26 27 22 28 34 21 20 19 25 18 24 32 37 1 38 39 3 41 42 40 40 ...

Page 23: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Nu...

Page 24: ...ner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this ap...

Reviews: