background image

32272-0-0713

Page 19

Keep the control compartment, logs and burner area surrounding the 

logs clean by vacuuming or brushing area at least twice a year.

THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN 

COOL.

Always turn off gas to the pilot before cleaning. For relighting, refer 

to lighting instructions located on the rating plate of the log set.

Never obstruct the flow of the combustion and ventilation air. Keep 

the front of the fireplace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the fireplace.

Screens should be closed during operation.

MAINTENANCE

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the 

gas quality or pressure is low, contact your local gas supplier immediately.

1.  When ignitor button is pressed, there is no spark at 

pilot. 

a.  Ignitor electrode positioned wrong - Replace pilot.

b.  Ignitor electrode is broken - Replace pilot.

c.  Ignitor electrode not connected to ignitor cable - Reconnect 

ignitor cable.

d.  Ignitor cable pinched or wet. Keep ignitor cable dry - Free 

ignitor cable if pinched by any metal or tubing. 

e.  Broken ignitor cable - Replace ignitor cable.

f.  Bad piezo ignitor - Replace piezo ignitor.

2.  Appliance produces unwanted odors.

a.  Appliance burning vapors from paint, hair spray, glues, etc. 

- Ventilate area. Stop using odor causing products while 

heater is running.

b.  Gas leak - Locate and correct all leaks.

3.  Appliance shuts off during use. (pilot and main burner are 

off.)

a.  Not enough fresh air is available for ODS/pilot to operate - 

Open window and/or door for ventilation.

b.  Low line pressure - Contact local gas company.

c.  ODS/pilot is partially clogged - Clean ODS/pilot.

d.  Defective thermocouple - Replace pilot.

4.  Appliance shuts off during use. (pilot stays on.)

a.  Low line pressure - Check line pressure to the valve.

b.  Defective  thermopile  -  Check  pilot  flame,  check  wire 

connections, output should be a minimum of 325 millivolts 

across. TH/TP and TP terminals with ON/OFF switch off.

5.  Gas odor even when control knob is in OFF position.

a.  Gas leak - Locate and correct all leaks.

b.  Control valve defective - Replace control valve.

6.  When ignitor button is pressed, there is spark at pilot, but 

no ignition.

a.  Gas supply turned off or manual shutoff valve closed - Turn 

on gas supply or open manual shutoff valve.

b.  Control knob not in PILOT position - Turn control knob to 

PILOT position.

c.  Control knob not pressed in while in PILOT position - Press 

in control knob while in PILOT position.

d.  Air in gas lines when installed - Continue holding down control 

knob. Repeat igniting operation until air is removed.

e. Pilot is clogged - Replace pilot assembly or get it 

serviced.

f.  Gas regulator setting is not correct - Replace gas 

regulator. 

7.  Pilot  lights  but  flame  goes  out  when  control  knob  is 

released.

a.  Control knob not fully pressed in - Press in control knob 

fully.

b.  Control knob not pressed in long enough - After pilot lights, 

keep control knob pressed in 30 seconds.

c.  Manual Shutoff valve not fully open - Fully open manual 

shutoff valve.

d.  Thermocouple connection loose at control valve - Hand 

tighten until snug, then tighten 1/4 turn more.

e.  Pilot  flame  not  touching  thermocouple,  which  allows 

thermocouple to cool, causing pilot flame to go out. This 

problem could be caused by either low gas pressure or dirty 

or partially clogged pilot - Contact local gas company. 

f.  Thermocouple damaged - Replace thermocouple.

g.  Control valve damaged - Replace control valve.

8.  Burner does not light after pilot is lit.

a.  Burner orifice clogged - Clean burner or replace main burner 

orifice.

b.  Burner  orifice  diameter  is  too  small  -  Replace  burner 

orifice.

c.  Inlet  gas  pressure  is  too  low  -  Contact  qualified  service 

person. 

9.  If burning at main burner orifice occurs (a loud, roaring 

blow torch noise).

a.  You must turn off burner assembly and contact a qualified 

service person.

b.  Manifold pressure is too low - Contact local gas company.

c.  Burner  orifice  clogged  -  Clean  burner  or  replace  burner 

orifice.

10.  Logs appear to smoke after initial operation.

a.  Vapors from paint or curing process of logs - Problem will 

stop after a few hours of operation. 

  Log heater is intended to be smokeless. Turn OFF heater 

and call qualified service person.

11.  Heater produces a whistling noise when main burner is 

lit.

a.  Turning control knob to HIGH position when main burner is 

cold - Turn control knob to LOW position and let warm up 

for a minute.

b.  Air in gas line - Operate burner until air is removed from 

line. Have gas line checked by local gas company.

c.  Dirty or partially clogged burner orifice - Clean burner or 

replace burner orifice.

12.  No gas to pilot.

a.  LP-regulator shut down due to inlet pressure too high - 

Verify LP tank regulator is installed and set at 11" to 13" 

w.c. Replace regulator on heater.

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.

TROUBLESHOOTING

SYMpTOMS - pOSSIBLE CAUSES AND CORRECTIONS

Summary of Contents for OP36FP32MN-2

Page 1: ... plier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If the information in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WA...

Page 2: ...Fireplace Framing and Installation 13 Gas Line Connection 13 Operation Instructions Flame Appearance 13 OP 36 42 FP72 Lighting Instructions 14 OP 36 42 FP32 Lighting Instructions 15 Pilot and Main Burner Flame Characteristics 16 Wiring 16 17 Remote Control Installation Operation 18 Maintenance 19 Troubleshooting 19 Parts List 20 21 Parts View 22 Master Parts Distributor List 23 How To Order Repair...

Page 3: ... to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION Do Not Operate THIS Gas Log Set With Glass Doors Closed DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoid...

Page 4: ...gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you detect any odor ...

Page 5: ...NG Thisapplianceisequippedfor naturalgasorpropane gas Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with this fireplace 3 Installer should show owner how to start and operate unvented room heater AlwaysconsultyourlocalBuildingDepartment regardin...

Page 6: ...f the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equally sized spaced at 180 degrees 3 14rad and unob structed Each opening shall have a total free area of not less than 1 2 square inch per pound 2 3 sq cm kg of stored fuel capacity and not less than a t...

Page 7: ...ual main gas cock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be checked for leaks by the installer This should be done with a soap so...

Page 8: ...ireplace models must use the hood supplied with the fireplace If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 2 Figure 2 Mantel Clearances CLEARANCES Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 3 No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplac...

Page 9: ...CE LETTER OP36FP OP42FP A 41 7 8 41 7 8 B 41 5 8 43 1 8 C 19 1 4 19 1 4 D 32 1 4 36 1 4 E 34 7 8 34 7 8 F 36 40 G 24 24 H 6 3 8 6 3 8 I 30 3 8 30 3 8 J 8 3 8 8 3 8 K 5 1 4 5 1 4 L 37 5 8 39 5 8 M 75 3 8 79 1 4 N 2 11 16 2 11 16 O 8 1 8 8 1 8 O N C J K G I A H F B D L M E ...

Page 10: ...han a safety issues Typical installation may include covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 92 inches Outdoor Fireplace Enclosure Requirements Do not install appliance until all necessary provisions are made for combustion and ventilation air Consult the written instructions provided with the appliance for informat...

Page 11: ...idic applications such as mortar or stone etching do not remove the protective PVC film from the stainless steel until after this application is complete Once the film has been removed we recommend that the appli ance be cleaned with a stainless steel cleaner immediately FIREPLACE FRAMING AND INSTALLATION Locate the three metal framing studs SIDE TOP OP36FP Two 42 Stud One 41 5 8 Stud OP42FP Two 4...

Page 12: ...a pan head screw through the middle bracket and into the top stud 5 Locate the two non combustible boards and place them above the fireplace as shown in Figure 11 Attach the non combustible board to the studs with six 10 16 flathead screws 6 Secure the non combustible board to the middle bracket using two 10 16 flathead screws as shown in Figure 11 7 Move the fireplace into position Connect the ga...

Page 13: ...er operation OPERATION INSTRUCTIONS FLAME APPEARANCE Millivolt Figure 15 Figure 13 GAS LINE CONNECTION Figure 14 GAS ACCESS HOLES The fireplace is designed to accept a 3 8 inch gas line for an approved ventless gas logset Have the line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 i...

Page 14: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise to OFF Do not force 1 STOP Read the safety information above 2 Turn gas cock counterclockwise to ON position 3 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If...

Page 15: ...This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in y...

Page 16: ...valve does not require 110 volts Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all optional switches Use the two leads Red and Green to attach optional components Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range WIRING Pilot Flame Pattern Figure 16 If pilot flame pattern is incorrec...

Page 17: ...Learn MOTOR COMM POWER IPI Continuous Pilot Off On Remote Off S I ADJ GND HI LO Solenoid ORANGE IGNITOR BLACK SENSOR BLACK ORANGE GREEN WHITE BROWN PILOT GAS CONTROL VALVE ELECTRONIC CONTROL MODULE N A AF 4000 B P RED BLACK BLACK BROWN RED ORANGE N A Figure 18 ...

Page 18: ...al use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on the module is in the REMOTE position the module will NOT LEARN if the slide switch is in the OFF position Press and release the LEARN button on the module to accept the transmitter security code and...

Page 19: ...rn control knob to Pilot position c Control knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat igniting operation until air is removed e Pilot is clogged Replace pilot assembly or get it serviced f Gas regulator setting is not correct Replace gas regulator 7 Pilot lights but flame goes out wh...

Page 20: ... 20237 Hood 13 R11036 R11036 R11037 R11037 Curtain Rod 14 R10765 R10765 R10765 R10765 Curtain Screen 15 27934 27934 27935 27935 Rear Log Support 16 27930 27930 27930 27930 Burner Support Left 17 27932 27932 27932 27932 Burner Support Right 18 27799 27799 27801 27801 Grate Tang Assembly 19 P253 P253 P253 P253 Orifice Fitting 20 P280 P280 P280 P280 Orifice Nat 20 P245 P245 P300 P300 Orifice LP 21 R1...

Page 21: ...8 27800 28088 27800 Ignitor Bracket 35 28081 28081 Valve Bracket 36 31514 31514 Water Shield 37 32231 32231 32331 32231 Metal Channel Side 38 32233 32233 32234 32234 Metal Channel Top 39 R11681 R11681 R11683 R11683 Non Combustible Board 40 10554 10554 10554 10554 Flanges 41 R10072 R10072 R10072 R10072 Shut Off Valve NS 28748 28748 28748 28748 Gas Line Cover NS R10815 R10815 Remote Control NS Not S...

Page 22: ...32272 0 0713 Page 22 PARTS VIEW 29 31 30 10 8 6 5 1 12 2 13 13 14 37 8 9 11 7 4 33 36 35 18 21 20 19 16 22 28 15 17 25 34 15 16 23 17 26 27 22 28 34 21 20 19 25 18 24 32 37 1 38 39 3 41 42 40 40 ...

Page 23: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Nu...

Page 24: ...ner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this ap...

Reviews: