Hearths should slope away from the front of the fireplace and chase 

at 1/8 in to 1/4 in per foot. Metal safety strips must be on top of any 

combustible hearth materials used for moisture management.

Screened Porch Installation

The fireplace may be installed safely and is design certified by CSA 

to be installed in a screen porch with the following guidelines.

Minimum Porch Area 

96 sq. feet (9 sq m)

Minimum Ceiling Height 

92" (234 cm)

Minimum of two (2) walls must be screened

Minimum top of screen height, side walls 

6'6" (198 cm)

Minimum screen area 

64 sq. feet (6 sq m)

Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other 

combustible material other than wood flooring the appliance shall 

be installed on a metal or wood panel extending the full width and 

depth of the appliance.  

The base referred to above does not mean the fire-proof base as 

used on wood stoves.  The protection is for rugs that are extremely 

thick and light colored tile.

Solid-fuels shall not be burned in a masonry or 

UL 127

 factory-built 

fireplace in which an unvented room heater is installed.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment  

or  accessories  and  repair  and  servicing  of  equipment  shall  be 

performed only by a  qualified agency.  The term "qualified agency" 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible for 

(a) the installation or replacement of gas piping or (b) the connection, 

installation, repair or servicing of equipment, who is experienced in 

such work, familiar with all precautions required and has complied 

with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by 

a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts.

The installation must conform with local codes or, in the absence of 

local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc.  1430 

Broadway, New York, N.Y. 10018.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be 

reduced at the rate of 4 percent for each 1,000 feet (305m) above 

sea level. Contact the manufacturer or your gas company before 

changing spud/orifice size.

Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect the 

Btu output of the unit. Contact the gas company for the heating value. 

Contact the manufacturer or your gas company before changing 

spud/orifice size.

WARNING:

 This appliance is equipped for (natural gas or propane) 

gas. Field conversion is not permitted.

Instructions to Installer

1. Installer must leave instruction manual with owner after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with this fireplace.

3.  Installer should show owner how to start and operate unvented 

room heater.

Always consult your local Building Department  regarding regulations, 

codes or ordinances which apply to the installation of an unvented 

room heater.
*Aftermarket:  Completion of sale, not for purpose of resale, from 

the manufacturer.

This appliance is only for use with the type of gas indicated on the 

rating plate.  This appliance is not convertible for use with other 

gases.

 

WARNING

ANY CHANGE TO THIS APPLIANCE OR ITS CONTROLS CAN 

BE DANGEROUS. 

Improper installation or use of the appliance can cause se-

rious injury or death from fire, burns, explosion or carbon 

monoxide poisoning.

This series is design certified in accordance with American National 

Standard Z21.97.1/CSA 2.41 by the Canadian Standards Association 

Laboratories as an Outdoor Gas Fireplace and should be installed 

according to these instructions.

Any alteration of the original design, installed other than as 

shown in these instructions or use with a type of gas not 

shown on the rating plate is the responsibility of the person 

and company making the change.
750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts 

(electrical current) which energizes the magnet in the gas valve. 

After 30 seconds to 1 minute time period you can release the gas 

control knob and the pilot will stay ON. Allow your pilot flame to 

operate an additional one (1) to two (2) minutes before you turn the 

gas control knob from the PILOT position to the ON position. This 

time period allows the millivolts (electrical energy) to build-up to a 

sufficient level allowing the gas control to operate properly. 

Important

All correspondence should refer to complete Model Number, Serial 

Number and type of gas.

Moisture Resistance

This outdoor fireplace will shed moderate amounts of water, but is 

not waterproof. Water and condensing water vapor may enter the 

chase under certain conditions.

The fireplace will not perform as an exterior wall. Moisture penetration 

must  be  considered  for  construction  that  places  the  fireplace  in 

structure walls or on moisture sensitive surfaces.

When installed on exterior walls: Empire Comfort Systems 

recommends  the  fireplace  chase  be  constructed  outside  the 

structure's weather envelope. Where the platform meets the wall, use 

a flashing detail similar to that required for attached decks. Chase 

platforms, including hearths should slope away from the structure 

at 1/4 in per foot. The fireplace can be shimmed level.

When installed on surfaces where water may collect or cause 

damage: Empire Comfort Systems recommends a slope of 1/8 in 

to 1/4 in per foot towards the drain port suggested. The fireplace 

can be shimmed level.

INTRODUCTION

Summary of Contents for OP36FP32M(N,P)-1

Page 1: ...RNING If the information in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment...

Page 2: ...ation 11 Fireplace Framing and Installation 12 Operation Instrucitons Flame Appearance 13 OP 36 42 FP72 Lighting Instructions 14 OP 36 42 FP32 Lighting Instructions 15 Pilot and Main Burner Flame Char...

Page 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION DO NOT OPERATE...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Page 5: ...staller 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with this fireplace 3 Installer should show owner h...

Page 6: ...of the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equa...

Page 7: ...al main gas cock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Co...

Page 8: ...Ceiling Clearances The ceiling height should not be less than 36 from the top of the hood Mantel Clearances Ventless fireplace models must use the hood supplied with the fireplace If a combustible man...

Page 9: ...mantel of your fireplace This is a fire hazard Figure 3 No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplace This is a heating appliance The flow o...

Page 10: ...42FP A 37 5 8 37 5 8 B 39 1 2 43 1 2 C 19 13 16 19 13 16 D 33 37 E 35 35 F 36 40 G 24 3 8 24 3 8 H 6 1 8 6 1 8 I 30 9 16 30 9 16 J 8 3 8 8 3 8 K 5 3 4 5 3 4 L 36 3 16 38 3 16 M 72 3 8 76 3 8 N 2 11 16...

Page 11: ...ude covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 82 inches Minimum of two walls to be open or screened to the following gu...

Page 12: ...AMING REQUIRED COMBUSTIBLE MATERIAL NOT ALLOWED ADJACENT TO FIREPLACE NOTE FINISH MUST BE CONCRETE BOARD OR NON COMBUSTIBLE MATERIAL OP36FP OP42FP A 38 1 2 38 1 2 B 40 44 C 19 3 8 19 3 8 Attention Add...

Page 13: ...nd will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Logs brush with soft b...

Page 14: ...he appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise...

Page 15: ...his appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to...

Page 16: ...after the pilot orifice has been removed To Remove Pilot Orifice 1 Disconnect the pilot supply line at the pilot burner 2 Remove pilot orifice from pilot burner It may be necessary to tap on pilot bu...

Page 17: ...omponents Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the...

Page 18: ...T Learn MOTOR COMM POWER IPI Continuous Pilot Off On Remote Off S I ADJ GND HI LO Solenoid ORANGE BLACK BLACK ORANGE GREEN WHITE BROWN PILOT GAS CONTROL VALVE ELECTRONIC CONTROL MODULE N A AF 4000 B P...

Page 19: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Page 20: ...n control knob to PILOT position c Control knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat...

Page 21: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Page 22: ...27932 27932 27932 27932 Burner Support Right 18 27799 27799 27801 27801 Grate Tang Assembly 19 P253 P253 P253 P253 Orifice Fitting 20 P209 P209 P209 P209 Orifice Nat 20 P245 P245 P300 P300 Orifice LP...

Page 23: ...27777 2 0212 Page 23 PARTS VIEW 29 31 30 10 8 6 5 1 12 2 13 13 14 3 3 8 9 11 7 4 33 24 35 18 21 20 19 16 22 28 15 17 25 34 15 16 23 17 26 27 22 28 34 21 20 19 25 18 24 32...

Page 24: ...must be installed by a qualified installer and operated in accordance with the written instructions furnished with the appliance Ready access to the appliance for service is the responsibility of the...

Reviews: