background image

27777-2-0212

Page 19

TWO-FUNCTION WIRELESS REMOTE CONTROL SYSTEM

FOR ON/OFF-HI/LO OPERATION OF THE AF-4000 GAS CONTROL VALVE

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT 

ATTEMPT TO OPERATE

INTRODUCTION

This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for use with the AF-4000 

gas control valve used with some gas heating appliances. The system operates on radio frequencies (RF) within a 20’ range using non-

directional signals. The system operates on one of 255 security codes that are programmed into the transmitter at the factory; the remote 

receiver must learn the transmitter code prior to initial use.

TRANSMITTER

This remote control TRANSMITTER offers the user a battery-operated hand held control to 

operate the AF-4000 control module functions that are used with some decorative gas fire

-

places and other gas heating appliances.

The transmitter operates with a 12V battery (Included) made specifically for remote controls 

and electronic lighters. Before using the transmitter, install the 12-volt (A-23) battery in the 

battery compartment. 

It is recommended that ALKALINE batteries always be used for longer battery life and maxi-

mum operational performance.

The transmitter has ON/OFF and HI/LO functions that are activated by pressing the button 

on the face of the transmitter. When a button on the transmitter is pressed, a signal light on 

the transmitter illuminates to verify that a signal is being sent. Upon initial use, there may be 

a delay of three seconds before the remote receiver will respond to the transmitter. This is 

part of the system’s design. If the signal light does not illuminate, check the position of the 

transmitter’s battery.

MATCHING SECURITY CODES

Each transmitter can use one of 255 unique security codes. It may be necessary to program (LEARN FUNCTION) the module to accept 

the transmitter security code upon initial use, if batteries are replaced, or if a replacement transmitter is purchased from your dealer or the 

factory. In order for the module to accept the transmitter security code, be sure the slide button on the module is in the REMOTE position; 

the module will NOT “LEARN” if the slide switch is in the OFF position. Press and release the LEARN button on the module to accept the 

transmitter security code and then pressing any button on the transmitter. A change in the beeping pattern, at the module, indicates the 

transmitter’s code has been accepted into the module. When an existing module has accepted the new transmitter code, the new security 

code will replace the old one.

The microprocessor that controls the security code matching procedure is controlled by a timing function. If you are unsuccessful in 

matching the security code on the first attempt, wait 1 - 2 minutes before trying again - this delay allows the microprocessor to reset its 

timer circuitry - and try up to two or three more times.

OPERATION

1.  This remote control will operate the AF-4000 gas control valves ON/OFF and flame height HI/LO of the main burner.

2.  When the ON button is depressed the transmitter sends a RF signal to the module. The module then sends 3 volts of power to the 

internal solenoid. The internal solenoid then opens the gas flow to the main burner ON/OFF. The system uses a pulse or continuous 

3 volts DC power to operate the flame HI/LO solenoid or flame HI/LOW DC motor drive.

BATTERY LIFE

Life expectancy of the alkaline batteries in the RCAF-3 TX can be up to 12 months depending on use of the solenoid function. Check and 

replace all batteries annually. The transmitter should operate with as little as 9.0 volts battery power.

SPECIFICATIONS

BATTERIES: 

Transmitter 12V - (A23)

Operating Frequency:  303.8 MHZ 

FCC ID No.’s: transmitter K9l1001

 

Canadian ISC ID No.’s: transmitter - 2439 102 728

FCC REQUIREMENTS

NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED 

MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE 

EQUIPMENT.

REMOTE CONTROL INSTALLATION & OPERATION

Summary of Contents for OP36FP32M(N,P)-1

Page 1: ...RNING If the information in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment...

Page 2: ...ation 11 Fireplace Framing and Installation 12 Operation Instrucitons Flame Appearance 13 OP 36 42 FP72 Lighting Instructions 14 OP 36 42 FP32 Lighting Instructions 15 Pilot and Main Burner Flame Char...

Page 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION DO NOT OPERATE...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Page 5: ...staller 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with this fireplace 3 Installer should show owner h...

Page 6: ...of the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equa...

Page 7: ...al main gas cock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Co...

Page 8: ...Ceiling Clearances The ceiling height should not be less than 36 from the top of the hood Mantel Clearances Ventless fireplace models must use the hood supplied with the fireplace If a combustible man...

Page 9: ...mantel of your fireplace This is a fire hazard Figure 3 No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplace This is a heating appliance The flow o...

Page 10: ...42FP A 37 5 8 37 5 8 B 39 1 2 43 1 2 C 19 13 16 19 13 16 D 33 37 E 35 35 F 36 40 G 24 3 8 24 3 8 H 6 1 8 6 1 8 I 30 9 16 30 9 16 J 8 3 8 8 3 8 K 5 3 4 5 3 4 L 36 3 16 38 3 16 M 72 3 8 76 3 8 N 2 11 16...

Page 11: ...ude covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 82 inches Minimum of two walls to be open or screened to the following gu...

Page 12: ...AMING REQUIRED COMBUSTIBLE MATERIAL NOT ALLOWED ADJACENT TO FIREPLACE NOTE FINISH MUST BE CONCRETE BOARD OR NON COMBUSTIBLE MATERIAL OP36FP OP42FP A 38 1 2 38 1 2 B 40 44 C 19 3 8 19 3 8 Attention Add...

Page 13: ...nd will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Logs brush with soft b...

Page 14: ...he appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise...

Page 15: ...his appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to...

Page 16: ...after the pilot orifice has been removed To Remove Pilot Orifice 1 Disconnect the pilot supply line at the pilot burner 2 Remove pilot orifice from pilot burner It may be necessary to tap on pilot bu...

Page 17: ...omponents Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the...

Page 18: ...T Learn MOTOR COMM POWER IPI Continuous Pilot Off On Remote Off S I ADJ GND HI LO Solenoid ORANGE BLACK BLACK ORANGE GREEN WHITE BROWN PILOT GAS CONTROL VALVE ELECTRONIC CONTROL MODULE N A AF 4000 B P...

Page 19: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Page 20: ...n control knob to PILOT position c Control knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat...

Page 21: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Page 22: ...27932 27932 27932 27932 Burner Support Right 18 27799 27799 27801 27801 Grate Tang Assembly 19 P253 P253 P253 P253 Orifice Fitting 20 P209 P209 P209 P209 Orifice Nat 20 P245 P245 P300 P300 Orifice LP...

Page 23: ...27777 2 0212 Page 23 PARTS VIEW 29 31 30 10 8 6 5 1 12 2 13 13 14 3 3 8 9 11 7 4 33 24 35 18 21 20 19 16 22 28 15 17 25 34 15 16 23 17 26 27 22 28 34 21 20 19 25 18 24 32...

Page 24: ...must be installed by a qualified installer and operated in accordance with the written instructions furnished with the appliance Ready access to the appliance for service is the responsibility of the...

Reviews: