background image

27777-2-0212

Page 20

Keep the control compartment, logs and burner area surrounding the 

logs clean by vacuuming or brushing area at least twice a year.

THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN 

COOL.

Always turn off gas to the pilot before cleaning. For relighting, refer 

to lighting instructions located on the rating plate of the log set.

Never obstruct the flow of the combustion and ventilation air. Keep 

the front of the fireplace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the fireplace.

Screens should be closed during operation.

MAINTENANCE

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the 

gas quality or pressure is low, contact your local gas supplier immediately.

1.  When ignitor button is pressed, there is no spark at 

pilot. 

a.  Ignitor electrode positioned wrong - Replace pilot.

b.  Ignitor electrode is broken - Replace pilot.

c.  Ignitor electrode not connected to ignitor cable - Reconnect 

ignitor cable.

d.  Ignitor cable pinched or wet. Keep ignitor cable dry - Free 

ignitor cable if pinched by any metal or tubing. 

e.  Broken ignitor cable - Replace ignitor cable.

f.  Bad piezo ignitor - Replace piezo ignitor.

2.  Appliance produces unwanted odors.

a.  Appliance burning vapors from paint, hair spray, glues, etc. 

- Ventilate area. Stop using odor causing products while 

heater is running.

b.  Gas leak - Locate and correct all leaks.

3.  Appliance shuts off during use. (Pilot and main burner are 

off.)

a.  Not enough fresh air is available for ODS/pilot to operate - 

Open window and/or door for ventilation.

b.  Low line pressure - Contact local gas company.

c.  ODS/pilot is partially clogged - Clean ODS/pilot.

d.  Defective thermocouple - Replace pilot.

4.  Appliance shuts off during use. (Pilot stays on.)

a.  Low line pressure - Check line pressure to the valve.

b.  Defective  thermopile  -  Check  pilot  flame,  check  wire 

connections, output should be a minimum of 325 millivolts 

across. TH/TP and TP terminals with ON/OFF switch off.

5.  Gas odor even when control knob is in OFF position.

a.  Gas leak - Locate and correct all leaks.

b.  Control valve defective - Replace control valve.

6.  When ignitor button is pressed, there is spark at pilot, but 

no ignition.

a.  Gas supply turned off or manual shutoff valve closed - Turn 

on gas supply or open manual shutoff valve.

b.  Control knob not in PILOT position - Turn control knob to 

PILOT position.

c.  Control knob not pressed in while in PILOT position - Press 

in control knob while in PILOT position.

d.  Air in gas lines when installed - Continue holding down control 

knob. Repeat igniting operation until air is removed.

e. Pilot is clogged - Replace pilot assembly or get it 

serviced.

f.  Gas regulator setting is not correct - Replace gas 

regulator. 

7.  Pilot  lights  but  flame  goes  out  when  control  knob  is 

released.

a.  Control knob not fully pressed in - Press in control knob 

fully.

b.  Control knob not pressed in long enough - After pilot lights, 

keep control knob pressed in 30 seconds.

c.  Manual Shutoff valve not fully open - Fully open manual 

shutoff valve.

d.  Thermocouple connection loose at control valve - Hand 

tighten until snug, then tighten 1/4 turn more.

e.  Pilot  flame  not  touching  thermocouple,  which  allows 

thermocouple to cool, causing pilot flame to go out. This 

problem could be caused by either low gas pressure or dirty 

or partially clogged pilot - Contact local gas company. 

f.  Thermocouple damaged - Replace thermocouple.

g.  Control valve damaged - Replace control valve.

8.  Burner does not light after pilot is lit.

a.  Burner orifice clogged - Clean burner or replace main burner 

orifice.

b.  Burner  orifice  diameter  is  too  small  -  Replace  burner 

orifice.

c.  Inlet  gas  pressure  is  too  low  -  Contact  qualified  service 

person. 

9.  If burning at main burner orifice occurs (a loud, roaring 

blow torch noise).

a.  You must turn off burner assembly and contact a qualified 

service person.

b.  Manifold pressure is too low - Contact local gas company.

c.  Burner  orifice  clogged  -  Clean  burner  or  replace  burner 

orifice.

10.  Logs appear to smoke after initial operation.

a.  Vapors from paint or curing process of logs - Problem will 

stop after a few hours of operation. 

  Log heater is intended to be smokeless. Turn OFF heater 

and call qualified service person.

11.  Heater produces a whistling noise when main burner is 

lit.

a.  Turning control knob to HIGH position when main burner is 

cold - Turn control knob to LOW position and let warm up 

for a minute.

b.  Air in gas line - Operate burner until air is removed from 

line. Have gas line checked by local gas company.

c.  Dirty or partially clogged burner orifice - Clean burner or 

replace burner orifice.

12.  No gas to pilot.

a.  LP-regulator shut down due to inlet pressure too high - 

Verify LP tank regulator is installed and set at 11" to 13" 

w.c. Replace regulator on heater.

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.

TROUBLESHOOTING

SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS

Summary of Contents for OP36FP32M(N,P)-1

Page 1: ...RNING If the information in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment...

Page 2: ...ation 11 Fireplace Framing and Installation 12 Operation Instrucitons Flame Appearance 13 OP 36 42 FP72 Lighting Instructions 14 OP 36 42 FP32 Lighting Instructions 15 Pilot and Main Burner Flame Char...

Page 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION DO NOT OPERATE...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Page 5: ...staller 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with this fireplace 3 Installer should show owner h...

Page 6: ...of the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equa...

Page 7: ...al main gas cock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Co...

Page 8: ...Ceiling Clearances The ceiling height should not be less than 36 from the top of the hood Mantel Clearances Ventless fireplace models must use the hood supplied with the fireplace If a combustible man...

Page 9: ...mantel of your fireplace This is a fire hazard Figure 3 No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplace This is a heating appliance The flow o...

Page 10: ...42FP A 37 5 8 37 5 8 B 39 1 2 43 1 2 C 19 13 16 19 13 16 D 33 37 E 35 35 F 36 40 G 24 3 8 24 3 8 H 6 1 8 6 1 8 I 30 9 16 30 9 16 J 8 3 8 8 3 8 K 5 3 4 5 3 4 L 36 3 16 38 3 16 M 72 3 8 76 3 8 N 2 11 16...

Page 11: ...ude covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 82 inches Minimum of two walls to be open or screened to the following gu...

Page 12: ...AMING REQUIRED COMBUSTIBLE MATERIAL NOT ALLOWED ADJACENT TO FIREPLACE NOTE FINISH MUST BE CONCRETE BOARD OR NON COMBUSTIBLE MATERIAL OP36FP OP42FP A 38 1 2 38 1 2 B 40 44 C 19 3 8 19 3 8 Attention Add...

Page 13: ...nd will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Logs brush with soft b...

Page 14: ...he appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise...

Page 15: ...his appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to...

Page 16: ...after the pilot orifice has been removed To Remove Pilot Orifice 1 Disconnect the pilot supply line at the pilot burner 2 Remove pilot orifice from pilot burner It may be necessary to tap on pilot bu...

Page 17: ...omponents Check 750 Millivolt System Operation Millivolt system and all individual components may be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the...

Page 18: ...T Learn MOTOR COMM POWER IPI Continuous Pilot Off On Remote Off S I ADJ GND HI LO Solenoid ORANGE BLACK BLACK ORANGE GREEN WHITE BROWN PILOT GAS CONTROL VALVE ELECTRONIC CONTROL MODULE N A AF 4000 B P...

Page 19: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Page 20: ...n control knob to PILOT position c Control knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat...

Page 21: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...