background image

32274-0-0713

Page 3

• 

Installer: please leave these instructions with the owner for 

future reference

• 

This unit complies with ANSI Z21.97/CSA 2.41 and CSA 4.96 

U.S. for Outdoor Gas Fireplaces.

• 

Children and adults should be alerted to the hazard of high 

surface temperature and should stay away to avoid burns 

or clothing ignition.

• 

Young children should be carefully supervised when they 

are in the same area with the appliance.

• 

Clothing or other flammable materials should not be hung 

from the appliance, or placed on or near the appliance.

• 

Installation and repair should be done by a QUALIFIED 

SERVICE pERSON.  This appliance should be inspected 

before use and at least annually by a professional service 

person.  More frequent cleaning may be required due to 

insects, pollen build up, dust, etc.  It is imperative that 

the control compartments, burners, and circulating air 

passageways of the appliance be kept clean.

• 

Do not place trash, logs, or other articles on the log set 

during operation.

• 

During manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain oils, 

films or bonding agents.  These agents are not harmful, but 

may produce annoying smoke and smells as they are burned 

off during initial operation of the appliance.  This is a normal 

temporary occurrence. 

• 

WARNING: Keep appliance area clear and free from 

combustible materials, gasoline and other flammable vapors 

and liquids.

• 

WARNING: Any modification to this gas log set or to controls 

can be dangerous.  Improper installation or use of the gas 

log set can cause serious injury or death from fire, burns, 

explosion or carbon monoxide poisoning.

• 

Follow all local codes regarding installation, combustion 

and ventilation air or in the absence of local codes follow 

the National Fuel Gas Code ANSI Z223.1 (US installation), or 

CAN/CGA-B149, installation Code (Canada installation).

• 

Do not operate this log set with glass doors in the closed 

position. A fireplace screen must be in place when the log 

set is burning.

• 

Inspect the hose before each use of the appliance. 

• 

The hose assembly must be replaced prior to the ap-

pliance being into operation if there is evidence of ex-

cessive abrasion or wear, or if the hose is damaged. 

• 

Inspect the burner at least once a year.

IMpORTANT SAFETY INFORMATION

DO NOT OpERATE THIS GAS LOG SET WITH GLASS DOORS CLOSED.

DANGER

: Indicates a hazardous situation which, if not 

avoided, will result in death or serious injury. 

WARNING

: Indicates a hazardous situation which, if 

not avoided, could result in death or serious injury.

CAUTION

: Indicates a hazardous situation which, if not 

avoided, could result in minor or moderate injury.

NOTICE

: Addresses practices not related to personal in-

jury.

•  Children and adults should be alerted to the hazards of 

high surface temperatures and should stay away to avoid 

burns or clothing ignition.

•  Young children should be carefully supervised when they 

are in the same area as the appliance.

•  Clothing or other flammable material should not be placed 

on or near the appliance.

• 

Do not place trash or other articles on the log set during 

operation.

•  During manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain oils, 

films or bonding agents. These bonding agents are not 

harmful but may produce annoying smoke and smells as 

they are burned off during initial operation of the appliance. 

This is a normal temporary occurrence.  

•  Keep burner and control compartment clean. 

• 

Installation and repair should be done by a QUALIFIED 

SERVICE pERSON. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, etc. It 

is imperative that control compartments, burners and 

circulating air passageways of the appliance be kept 

clean.

•  Do

 keep the appliance area clear and free from combustible 

material,  gasoline  and  other  flammable  vapors  and 

liquids.

• 

A yearly examination and cleaning of the venting system 

of the solid-fuel burning fireplace must be performed by 

a qualified agency.

•  Do 

make a periodic visual check of pilot and burners. 

Clean and replace damaged parts.

•  Do NoT 

use this appliance if any part has been under 

water.  Immediately  call  a  qualified  service  technician 

to inspect the appliance and to replace any part of the 

control system and any gas control which has been under 

water. 

Summary of Contents for OLP36FP72S-2

Page 1: ...formation in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration ser...

Page 2: ...n 10 11 Fireplace Framing and Installation 12 13 Gas Line Connection 13 Operation Instructions Flame Appearance 14 OLP 36 42 FP72 Lighting Instructions 15 Main Burner Flame Characteristics 16 Wiring 1...

Page 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION Do Not Operate...

Page 4: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Page 5: ...as Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card suppl...

Page 6: ...the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equall...

Page 7: ...ock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Compounds used...

Page 8: ...ss fireplace models must use the hood supplied with the fireplace If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 2 Figure 2 Mantel Clearances CLEARANCE...

Page 9: ...nches REFERENCE LETTER OLP36FP OLP42FP A 41 7 8 41 7 8 B 41 5 8 43 1 8 C 19 1 4 19 1 4 D 32 1 4 36 1 4 E 34 7 8 34 7 8 F 36 40 G 24 24 H 6 3 8 6 3 8 I 30 3 8 30 3 8 J 8 3 8 8 3 8 K 5 1 4 5 1 4 L 37 5...

Page 10: ...than a safety issues Typical installation may include covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 92 inches WARNING This...

Page 11: ...develop some surface oxidation rust This does not affect the performance of the fireplace and does not require any action to correct If you prefer keeping your fireplace front looking factory fresh cl...

Page 12: ...e the bracket under the screw as shown in Figure 11 Tighten the hex head screws on the fireplace secure a pan head screw through the middle bracket and into the top stud 4 Slide the fireplace into pos...

Page 13: ...r for proper model Always use an external regulator for all LP fireplaces to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING C...

Page 14: ...ors remaining after this initial break in will be slight and will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid...

Page 15: ...e appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise...

Page 16: ...mproper and dangerous operation Verify proper operation after servicing 1 Remove batteries 4 and battery pack from instruction envelope package 2 Slide battery cover plate off of battery pack insert b...

Page 17: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Page 18: ...ontrol knob to LOW position and let warm up for a minute b Air in gas line Operate burner until air is removed from line Have gas line checked by local gas company c Dirty or partially clogged burner...

Page 19: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 20: ...423 Connector Male 5 16 X 3 8 NPT 18 28089 28089 Valve Shield 19 P253 P253 Orifice Fitting 20 P301 P209 Orifice Nat 20 P245 P265 Orifice LP 21 28111 28111 Module Shield 22 R10816 R10817 Burner Assembl...

Page 21: ...32274 0 0713 Page 21 PARTS VIEW 13 13 14 4 6 5 2 16 20 19 22 18 24 31 28 35 12 29 33 15 21 25 17 36 1 1 38 39 3 37 37 7 7 40 41 40...

Page 22: ...32274 0 0713 Page 22 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 23: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might r...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: