background image

32274-0-0713

Page 10

In  planning  the  installation  for  the  fireplace,  it  is  necessary  to 

determine where the unit is to be installed and whether optional 

accessories are desired. Gas supply piping should also be planned 

at this time.

The fireplace can be mounted on any of these surfaces:

1.  A flat hard combustible or non-combustible surface.

2.  A raised platform of non-combustible material.

3.  Four (4) corners of the fireplace so contact is made on all four 

perimeter edges on the bottom of the unit. 

 

(Example: Four (4) concrete masonry blocks.)

If the fireplace is installed directly on carpeting, tile or other 

combustible material other than wood flooring, it should be installed 

on a metal or wood panel extending the full width and depth of the 

unit.
At this point, you should have decided what components to include 

in your installation, and where the fireplace is to be located. If this 

has not been done, stop and consult your dealer for assistance 

with this planning.

This  fireplace  is  intended  for  installation  on  an  outdoor  patio  or 

in your yard.  This fireplace shall be used only outdoors in a well 

ventilated space and shall NOT be used in a building, garage, or 

other enclosed area.  

It is recommended that this fireplace be installed in a “sheltered” 

area.  Direct wind will cause an erratic flame and possible pilot or 

main burner outage.  This erratic flame could also lead to excessive 

black soot.  These issues are nuisance issues rather than a safety 

issues.  
Typical installation may include covered patio, screened porch, 

gazebo or an outside wall of a house.

• 

Minimum porch area – 96 square feet

• 

Minimum ceiling height – 92 inches

 

WARNING

This fireplace is not been tested nor approved to have a television 

or other electrical appliance installed above it.

Outdoor Fireplace Enclosure Requirements

Do not install appliance until all necessary provisions are made 

for combustion and ventilation air. Consult the written instructions 

provided with the appliance for information concerning combustion 

and ventilation air. In the absence of instructions, refer to the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion 

and Ventilation, or applicable local codes.

NOTICE: 

This fireplace is NoT equipped with an oDS pilot.

Installation must conform with one of the following conditions:

• 

With walls on all sides, but with no overhead cover;

• 

Within a partial enclosure which includes an overhead cover 

and no more than two side walls. These side walls may be 

parallel, as in a breezeway or at right angles to each side; or

• 

Within a partial enclosure which includes an overhead cover 

and three sidewalls, as long as 30% or more of the horizontal 

periphery of the enclosures is permanently open.

 

WARNING

Improper installation, adjustment, alteration, service or mainte-

nance can cause property damage, personal injury or loss of life. 

Installation and service must be performed by a qualified installer, 

service agency or the gas supplier.

Clearances

Figure 5

The front of the fireplace may have 0" clearance as far back as 1/2" 

where studs are to be placed.

Figure 6

pLANNING INSTALLATION

Summary of Contents for OLP36FP72S-2

Page 1: ...formation in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration ser...

Page 2: ...n 10 11 Fireplace Framing and Installation 12 13 Gas Line Connection 13 Operation Instructions Flame Appearance 14 OLP 36 42 FP72 Lighting Instructions 15 Main Burner Flame Characteristics 16 Wiring 1...

Page 3: ...to the ap pliance being into operation if there is evidence of ex cessive abrasion or wear or if the hose is damaged Inspect the burner at least once a year IMPORTANT SAFETY INFORMATION Do Not Operate...

Page 4: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Page 5: ...as Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card suppl...

Page 6: ...the enclosure shall be completely open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the side wall equall...

Page 7: ...ock should be located in the vicinity of the unit Where none exists or where its size or location is not adequate contact your local authorized installer for installation or relocation Compounds used...

Page 8: ...ss fireplace models must use the hood supplied with the fireplace If a combustible mantel is installed it must meet the clearance requirements detailed in Figure 2 Figure 2 Mantel Clearances CLEARANCE...

Page 9: ...nches REFERENCE LETTER OLP36FP OLP42FP A 41 7 8 41 7 8 B 41 5 8 43 1 8 C 19 1 4 19 1 4 D 32 1 4 36 1 4 E 34 7 8 34 7 8 F 36 40 G 24 24 H 6 3 8 6 3 8 I 30 3 8 30 3 8 J 8 3 8 8 3 8 K 5 1 4 5 1 4 L 37 5...

Page 10: ...than a safety issues Typical installation may include covered patio screened porch gazebo or an outside wall of a house Minimum porch area 96 square feet Minimum ceiling height 92 inches WARNING This...

Page 11: ...develop some surface oxidation rust This does not affect the performance of the fireplace and does not require any action to correct If you prefer keeping your fireplace front looking factory fresh cl...

Page 12: ...e the bracket under the screw as shown in Figure 11 Tighten the hex head screws on the fireplace secure a pan head screw through the middle bracket and into the top stud 4 Slide the fireplace into pos...

Page 13: ...r for proper model Always use an external regulator for all LP fireplaces to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING C...

Page 14: ...ors remaining after this initial break in will be slight and will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleaning fluid...

Page 15: ...e appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 1 Locate On Off gas cock and turn clockwise...

Page 16: ...mproper and dangerous operation Verify proper operation after servicing 1 Remove batteries 4 and battery pack from instruction envelope package 2 Slide battery cover plate off of battery pack insert b...

Page 17: ...l use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on...

Page 18: ...ontrol knob to LOW position and let warm up for a minute b Air in gas line Operate burner until air is removed from line Have gas line checked by local gas company c Dirty or partially clogged burner...

Page 19: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Page 20: ...423 Connector Male 5 16 X 3 8 NPT 18 28089 28089 Valve Shield 19 P253 P253 Orifice Fitting 20 P301 P209 Orifice Nat 20 P245 P265 Orifice LP 21 28111 28111 Module Shield 22 R10816 R10817 Burner Assembl...

Page 21: ...32274 0 0713 Page 21 PARTS VIEW 13 13 14 4 6 5 2 16 20 19 22 18 24 31 28 35 12 29 33 15 21 25 17 36 1 1 38 39 3 37 37 7 7 40 41 40...

Page 22: ...32274 0 0713 Page 22 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Page 23: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might r...

Page 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...