32274-0-0713
Page 16
If pilot flame pattern is incorrect
• See Troubleshooting, page 16.
Main Burner Flame pattern
The main burner flame will be completely yellow.
Main Burner Flame Ignition and Extinction
When the main burner is ignited it will take a few seconds for the full flame pattern to develop.
When the main burner is extinguished it will take a few seconds for the flames to disappear. It is normal to have the flames burn down
near the burner, as the remaining gas is burned.
MAIN BURNER FLAME CHARACTERISTICS
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
1. Remove batteries (4) and battery pack from instruction envelope package.
2. Slide battery cover plate off of battery pack, insert batteries (ensure correct polarity), and replace battery cover plate.
3. Connect red wire from battery pack to red wire from valve.
4. Connect black wire from battery pack to red wire from valve.
5. Attach wire harness from control module to battery pack.
6. Place battery pack on raised section of firebox bottom through hole in burner bottom.
WIRING
MAIN
PILOT
Learn
MOTOR
COMM.
POWER
IPI
Continuous
Pilo
t
Off/O
n
Remote/Off
S
I
ADJ.
(GND)
HI/LO
Solenoid
ORANGE
(IGNITOR)
BLACK
(SENSOR)
BLACK
ORANGE
GREEN
WHITE
BROWN
PILOT
GAS CONTROL
VALVE
ELECTRONIC
CONTROL MODULE
N/A
AF-4000 B/P
RED
BLACK
BLACK
BROWN
RED
ORANGE
N/A