33587-5-0820

Page 1

Empire Comfort Systems Inc. • Belleville, IL

ATTENTION:

 It is recommended to install the blower assembly 

before connecting gas inlet supply line.

WIRING

CAUTION

All  wiring  should  be  done  by  a  qualified  electrician  and 

shall be in compliance with all local, city and state building 

codes. Before making the electrical connection, make sure 

that  main  power  supply  is  disconnected.  The  appliance, 

when installed, must be electrically grounded in accordance 

with  local  codes,  with  the  National  Electrical  Code 

ANSI/

NFPA

 70 (Latest Edition).

The appliance, when installed, must be electrically grounded in 

accordance with local codes or, in the absence of local codes, 

with the

 National Electrical Code, ANSI/NFPA 70

, if an external 

electrical source is utilized. 

This  appliance  is  equipped  with 

a  three-prong  [grounding]  plug  for  your  protection  against 

shock hazard and should be plugged directly into a properly 

grounded three-prong receptacle. Do not cut or remove the 

grounding prong from this plug. 

For an ungrounded receptacle, 

an adapter, which has two prongs and a wire for grounding, can be 

purchased, plugged into the ungrounded receptacle and its wire 

connected to the receptacle mounting screw. With this wire com-

pleting the ground, the appliance cord plug can be plugged into the 

adapter and be electrically grounded.

CAUTION

Label all wires prior to disconnection when servicing controls. 

Wiring errors can cause improper and dangerous operation. 

Verify proper operation after servicing.

NOTICE:

 

The junction box must be pre-wired at time of fireplace 

installation for use with blower assembly. A standard wall ON/OFF 

wall switch or optional SCV1 Variable Speed Control Kit should be 

installed to activate power to the fireplace, and control the operation 

of the FBB5 Blower assembly. It is recommended that installation 

of the wiring be performed by a qualified electrician. 

See figure 1.

1. 

If installed, turn OFF gas supply to firebox/gas log.

2. 

If applicable, turn OFF electric supply to firebox.

Figure 1

INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION.

INSTALLATION INSTRUCTIONS

FBB5-1 BLOWER KIT

Summary of Contents for FBB5-1

Page 1: ...he grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded receptacle and its wire connected t...

Page 2: ...TABLE OF CONTENTS Standard Firebox Blower Installation 3 4 VFP SB PB Firebox Blower Installation 5 6 VFP SP PP Fireplace Blower Installation 7 8 DVP SP PP Fireplace Blower Installation 9 10 Maintenanc...

Page 3: ...s Figure 2 Deluxe Louvered shown Flush Face and Premium Models Figure 3 Deluxe Flush shown Select Firebox Models Figure 4 2 Remove air deflector by removing the four screws securing it to the blower a...

Page 4: ...astic purse clip provided 11 To complete the installation plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap See Figure 7 Figure 7 12 If room permi...

Page 5: ...es through the hole at the top of the firebox Feed the wires over the firebox top and down between the firebox side and outer wrap then secure the fan control switch with 2 6 screws provided See Figur...

Page 6: ...CATION Figure 10 HEARTH BLOWER ASSEMBLY CENTER AND INSTALL AGAINST OUTER WRAP AS SHOWN WIRES FROM FAN CONTROL SWITCH OUTER WRAP Figure 11 VFP SB PB FIREBOX BLOWER INSTALLATION USE SCVI VARIABLE SPEED...

Page 7: ...the top corner of the firebox Remove the plug with a standard screwdriver and discard plug 3 Next find the fan control switch and wire assembly Feed the wires through the hole at the top of the firebo...

Page 8: ...elleville IL HEARTH BLOWER ASSEMBLY CENTER AND INSTALL AGAINST OUTER WRAP AS SHOWN WIRES FROM FAN CONTROL SWITCH OUTER WRAP Figure 15 USE OF A STANDARD ON OFF WALL SWITCH TO OPERATE OPTIONAL BLOWER Fi...

Page 9: ...l switch to the tab See Figure 19 Once the fan control has been secured bend the tab forward so that the face of the fan control is pushed down so it contacts the firebox top 3 Next find the fan contr...

Page 10: ...587 5 0820 Page 10 Empire Comfort Systems Inc Belleville IL FAN CONTROL SWITCH Figure 19 USE OF A STANDARD ON OFF WALL SWITCH TO OPERATE OPTIONAL BLOWER Figure 20 DVP PP SP FIREPLACE BLOWER INSTALLATI...

Page 11: ...blower motor Blower Wheels The blower wheels will collect lint and could require periodic clean ing If the air output decreases or the noise level increases it indi cates a dirty blower wheel Remove f...

Page 12: ...el Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be...

Reviews: