background image

33587-5-0820

Page 5

Empire Comfort Systems Inc. • Belleville, IL

To install the blower kit, access the junction box, or install a light 

kit, remove the access cover plate and/or lower louvers or flush 

panels as illustrated by 

Figures 8 and 9.

A factory included junction box is located on the lower right side of 

the firebox. Wiring must be fed through the 7/8 inch diameter hole 

provided on the lower side of the firebox, and secured to the outer 

wrap with the clamp provided. 
Leave approximately 6 inches of wire in the junction box for 

connection.

NOTE:

 Depending on the unit, the Junction box may be installed 

on the outer side.
Attach black wire to the brass screw on the receptacle and attach 

the white wire to the silver screw. Attach ground wire (bare) to the 

green (ground) screw.
Install the receptacle into the junction box as illustrated. 

 

Attach cover plate. Place Junction Box so that it is approximately 8 

to 12 inches away from the outer wrap wall. Secure wiring at outer 

wrap of fireplace with wire clamp provided.

ATTENTION:

 If installed, do not damage gas inlet supply line 

when blower assembly is inserted into firebox. In some cases, re

-

moval of the gas inlet supply line may be necessary. 

Figure 8 - Flush Or Louvered Models

BLOWER AND JUNCTION

BOX ACCESS COVER

PLATE

Figure 9 - Flush Face Models With Raised Hearth Extensions

1. 

Insert blower assembly into interior, bottom of firebox. Position 

blower assembly so that you align the notch on back of blower 

assembly with the center screw on side/end panel, then push 

the blower assembly against firebox outer panel. The blower 

wheel must be centered with the side/end wall of the firebox. 

The magnets on the back and bottom of blower assembly will 

sufficiently hold blower assembly in place. 

See Figure 11.

2.  Once the blower assembly is in position, locate the plug but-

ton in the top corner of the firebox. Remove the plug with a 

standard screwdriver and discard plug.

3.  Next,  find  the  fan  control  switch  and  wire  assembly.  Feed 

the wires through the hole at the top of the firebox. Feed the 

wires over the firebox top and down between the firebox side 

and outer wrap then, secure the fan control switch with (2) #6 

screws provided. 

See Figure 10.

4.  The fan control wires will slide down between the firebox and 

outer wrap near the blower assembly. 

See Figure 11

.

5.  One fan control wire will have a 1/4 inch female terminal that 

must be attached to the open terminal on the blower motor. 

See Figure 22, Connection A.

6.  The other fan control wire has a 1/4 inch male terminal. Attach 

this terminal to the open terminal on the blower power cord. 

See Figure 22, Connection B

7.  Locate the ground wire attached to the blower base. Secure 

the opposite end with the ring tongue terminal to the outer 

bottom  of  the  fireplace  using  using  the  self  drilling  screw 

located in the hardware pack.

8.  Route the wires away from moving parts of the blower assem-

bly and retain wires together near the blower motor using the 

plastic purse clip provided.

9.  To complete the installation, plug the power cord into the junc-

tion box receptacle previously installed in the bottom of the 

firebox. 

See Figure 11.

10.  Once all connections are made electrically, it is recommended 

that you test the blower fan control operation by turning on 

power to the blower 

(CAUTION

: 110 Volt). 

Then apply heat to 

the fan control switch inside the firebox with a lighter or match 

until blower is activated. Once blower is activated, check for 

proper operation. Do not place hands near blower assembly 

or other wiring while power is on.

11.  Replace blower access plate and louvers or flush panels. 

See 

Figures 8 and 9.

12.  This completes the installation of the optional FBB5 Blower kit 

accessory.

NOTE: 

This blower is equipped with a heat activated fan control 

switch. Blower will operate when the firebox warms up, and will 

turn off automatically when the firebox cools down. The time will 

vary for the activation of the fan control switch depending on sev-

eral factors including firebox/log set sizing, BTU input variables, 

and log set positioning. Generally, it may take from 5 to 20 minutes 

to activate blower/fan control from a cold start.

VFP(SB,PB) FIREBOX BLOWER INSTALLATION

Summary of Contents for FBB5-1

Page 1: ...he grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded receptacle and its wire connected t...

Page 2: ...TABLE OF CONTENTS Standard Firebox Blower Installation 3 4 VFP SB PB Firebox Blower Installation 5 6 VFP SP PP Fireplace Blower Installation 7 8 DVP SP PP Fireplace Blower Installation 9 10 Maintenanc...

Page 3: ...s Figure 2 Deluxe Louvered shown Flush Face and Premium Models Figure 3 Deluxe Flush shown Select Firebox Models Figure 4 2 Remove air deflector by removing the four screws securing it to the blower a...

Page 4: ...astic purse clip provided 11 To complete the installation plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap See Figure 7 Figure 7 12 If room permi...

Page 5: ...es through the hole at the top of the firebox Feed the wires over the firebox top and down between the firebox side and outer wrap then secure the fan control switch with 2 6 screws provided See Figur...

Page 6: ...CATION Figure 10 HEARTH BLOWER ASSEMBLY CENTER AND INSTALL AGAINST OUTER WRAP AS SHOWN WIRES FROM FAN CONTROL SWITCH OUTER WRAP Figure 11 VFP SB PB FIREBOX BLOWER INSTALLATION USE SCVI VARIABLE SPEED...

Page 7: ...the top corner of the firebox Remove the plug with a standard screwdriver and discard plug 3 Next find the fan control switch and wire assembly Feed the wires through the hole at the top of the firebo...

Page 8: ...elleville IL HEARTH BLOWER ASSEMBLY CENTER AND INSTALL AGAINST OUTER WRAP AS SHOWN WIRES FROM FAN CONTROL SWITCH OUTER WRAP Figure 15 USE OF A STANDARD ON OFF WALL SWITCH TO OPERATE OPTIONAL BLOWER Fi...

Page 9: ...l switch to the tab See Figure 19 Once the fan control has been secured bend the tab forward so that the face of the fan control is pushed down so it contacts the firebox top 3 Next find the fan contr...

Page 10: ...587 5 0820 Page 10 Empire Comfort Systems Inc Belleville IL FAN CONTROL SWITCH Figure 19 USE OF A STANDARD ON OFF WALL SWITCH TO OPERATE OPTIONAL BLOWER Figure 20 DVP PP SP FIREPLACE BLOWER INSTALLATI...

Page 11: ...blower motor Blower Wheels The blower wheels will collect lint and could require periodic clean ing If the air output decreases or the noise level increases it indi cates a dirty blower wheel Remove f...

Page 12: ...el Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be...

Reviews: