STANDARD FIREBOX BLOWER INSTALLATION

Figure 6

6.  The fan control wires will slide down between the firebox and 

outer wrap near the blower assembly. 

See Figure 6.

7.  One fan control wire will have a 1/4 inch female terminal that 

must be attached to the open terminal on the blower motor. 

See Figure 22, Connection A.

8.  The other fan control wire has a 1/4 inch male terminal. Attach 

this terminal to the open terminal on the blower power cord. 

See Figure 22, Connection B.

9.  Locate the ground wire attached to the blower base. Secure 

the opposite end with the ring tongue terminal to the outer 

bottom  of  the  fireplace  using  using  the  self  drilling  screw 

located in the hardware pack.

10.  Route the wires away from moving parts of the blower assembly 

and retain wires together near the blower motor using the plastic 

purse clip provided.

11.  To complete the installation, plug the power cord into the junction 

box receptacle at the right rear corner of the firebox oute

r wrap. 

See Figure 7.

Figure 7

12.  If room permits, the power cord can be located from the out-

side of the unit looking through the junction box access hole 

(with the junction box removed), then plug up the power cord 

before reinstalling the pre-wired junction box.

13.  Once all electrical connections are made test the blower fan 

control operation by turning on power to the blower. Apply 

heat to the fan control switch inside the firebox with a lighter 

or match until blower is activated. Once blower is activated, 

check for proper operation. 

WARNING

Do not place hands near blower assembly or other wiring 

while power is on.

14.  Replace blower access plate.

15.  This completes the installation of the optional FBB5 Blower kit 

accessory.

NOTICE:

 

This blower is equipped with a heat activated fan control 

switch. Blower will operate when the fireplace warms up, and will 

turn off automatically when the firebox cools down.

Summary of Contents for FBB5-1

Page 1: ...he grounding prong from this plug For an ungrounded receptacle an adapter which has two prongs and a wire for grounding can be purchased plugged into the ungrounded receptacle and its wire connected t...

Page 2: ...TABLE OF CONTENTS Standard Firebox Blower Installation 3 4 VFP SB PB Firebox Blower Installation 5 6 VFP SP PP Fireplace Blower Installation 7 8 DVP SP PP Fireplace Blower Installation 9 10 Maintenanc...

Page 3: ...s Figure 2 Deluxe Louvered shown Flush Face and Premium Models Figure 3 Deluxe Flush shown Select Firebox Models Figure 4 2 Remove air deflector by removing the four screws securing it to the blower a...

Page 4: ...astic purse clip provided 11 To complete the installation plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap See Figure 7 Figure 7 12 If room permi...

Page 5: ...es through the hole at the top of the firebox Feed the wires over the firebox top and down between the firebox side and outer wrap then secure the fan control switch with 2 6 screws provided See Figur...

Page 6: ...CATION Figure 10 HEARTH BLOWER ASSEMBLY CENTER AND INSTALL AGAINST OUTER WRAP AS SHOWN WIRES FROM FAN CONTROL SWITCH OUTER WRAP Figure 11 VFP SB PB FIREBOX BLOWER INSTALLATION USE SCVI VARIABLE SPEED...

Page 7: ...the top corner of the firebox Remove the plug with a standard screwdriver and discard plug 3 Next find the fan control switch and wire assembly Feed the wires through the hole at the top of the firebo...

Page 8: ...elleville IL HEARTH BLOWER ASSEMBLY CENTER AND INSTALL AGAINST OUTER WRAP AS SHOWN WIRES FROM FAN CONTROL SWITCH OUTER WRAP Figure 15 USE OF A STANDARD ON OFF WALL SWITCH TO OPERATE OPTIONAL BLOWER Fi...

Page 9: ...l switch to the tab See Figure 19 Once the fan control has been secured bend the tab forward so that the face of the fan control is pushed down so it contacts the firebox top 3 Next find the fan contr...

Page 10: ...587 5 0820 Page 10 Empire Comfort Systems Inc Belleville IL FAN CONTROL SWITCH Figure 19 USE OF A STANDARD ON OFF WALL SWITCH TO OPERATE OPTIONAL BLOWER Figure 20 DVP PP SP FIREPLACE BLOWER INSTALLATI...

Page 11: ...blower motor Blower Wheels The blower wheels will collect lint and could require periodic clean ing If the air output decreases or the noise level increases it indi cates a dirty blower wheel Remove f...

Page 12: ...el Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be...

Reviews: