background image

21552-0-0506

Page 1

Empire Comfort Systems, Inc.

DVVK-4FV Direct Vent Vertical Termination Kit

Installation Instructions

This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with 

DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the 

fireplace model number. Check that this flex vent system is listed for use with your fireplace model prior to 

starting the installation.

IMPORTANT SAFETY INFORMATION

•  The vertical termination cap MUST be vented directly to the 

outside. The termination kit MUST NEVER be connected to 

a chimney flue(s) servicing a separate solid-fuel burning ap-

pliance or any other appliances.

•  Termination cap MUST NOT be mounted horizontally.

•  The flexible vent pipe cannot be intermingled with any of the 

rigid vent pipe section(s). DO NOT connect two sections of 

flexible vent pipe together to achieve a longer length without 

the use of approved connectors.

•  The installation must conform with local codes or in the ab-

sence of local codes, with the National Fuel Gas Code, ANSI 

Z223.1 (in the United States) or with the current installation 

code CAN/CGA B149 (in Canada).

•  Only  Direct  Vent  fireplaces  approved  for  use  with  Empire 

Comfort Systems, Inc. DVVK-4FV termination kit shall be 

used. See PARTS LIST/ILLUSTRATIONS section for vent 

component identification.

•  Horizontal vent runs must be supported every 2 feet using 

wall straps. Vertical runs must be supported every 3 feet us-

ing wall straps. Slip wall straps loosely on to pipe. Attach 

installer provided straps to framing members using nails or 

screws.

•  The fireplace and venting system should be inspected before 

initial use and at least annually by a qualified field service 

person.  Inspect  the  external  vent  cap  on  a  regular  basis  to 

make sure that no debris is interfering with the airflow. In-

spect entire venting system to ensure proper function.

•  Please refer to the fireplace instructions for information on 

Termination Cap clearances.

This vent kit may be installed as an OEM installation in a manufactured home (USA only) or mobile 

home and must be installed in accordance with the manufacturer’s instructions and the manufactured 

home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile 

Homes, CAN/CSA Z240 MH.

CAUTION

All Fireplaces listed for use with the DVVK-4FV will operate safely when installed in accordance with this instruction manual. Read 

all instructions before starting installation, then follow these instructions carefully to maximize fireplace performance and safety. 

Report damaged parts to your dealer.

WARNING

Any common venting of the gas appliance using the DV vent kit with other gas appliances is not allowed. Do not connect this appli-

ance to a chimney flue servicing a separate solid fuel-burning appliance.

WARNING

Failure to follow these instructions may create a possible fire hazard and will void the warranty.

WARNING

Always maintain minimum clearances around vent systems. The minimum clearance to combustibles for horizontal runs of vent pipe 

is 3 inches from the top, and 1 inch from the sides and bottom of the vent system. Do not pack the open air spaces around the fireplace 

or flue with insulation or other materials. Any horizontal run must have a 1/4” rise for every one (1) foot of run towards the vent ter-

mination. The vent above the roof must terminate vertically.

WARNING

Contact your Local Building and Fire Officials about restrictions and installation inspections in your area.

Summary of Contents for DVVK-4FV

Page 1: ...ted before initial use and at least annually by a quali ed eld service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air ow In spect entir...

Page 2: ...e Vertical Flex Termination Kit WARNING Ensure that the venting system exits the structure through the roof and does not terminate less than 12 inches 305mm above the roof WARNING Refer to your replac...

Page 3: ...his opening must be large enough to provide a mini mum 1 air space clearance from the vertical vent pipe to any combustible framing 6 Install the Firestop Thimble assembly to the framed opening in the...

Page 4: ...f cutout opening see step 5 Feed the ex vent end down through the roof opening and restop thimble assembly installed in step 4 14 Secure the roof support assembly to the roof sheathing with at least 4...

Page 5: ...that may be used as an attic insulation shield The collar can be installed around the ex pipe or hard pipe just above the restop thimble This collar will act as a shield to prevent blown in sulation...

Page 6: ...imble Ceiling Straps As Req d Venting Support With Gasket Clamps 7 Dia Adapter Collar 4 Dia Flue Connector Assembly Firestop Thimble Adjustable Storm Collar Use To Keep Keep Insulation Out Of Inlet Ve...

Page 7: ...Ply Alum Flex 7 Diameter by 6 ft MF07ALA2F006 1 5 4 7 x 48 Rigid Pipe Assembly MF100554 1 6 Firestop Thimble Assembly MF100124 1 7 Roof Flashing 0 12 to 6 12 MF100091 1 8 7 Flex Adapter Collar with G...

Page 8: ...21552 0 0506 Page 8 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Reviews: