34829-1-0115
Page 6
FIREPLACE DIMENSIONS
P
C
J
E
A
I
B
H
D
A
TOP VIEW
FRONT VIEW
SIDE VIEW
F
K
L
M
Q
R
O
N
INDEX
LETTER
DIMENSION DESCRIPTION
DVTT36 & DVLT36
DVTT42 & DVLT42
Dimensions in Inches
A
The maximum height of firebox face (excluding standoffs)
39-5/16
45-5/16
B
The maximum width of the firebox face (excluding nailing flanges)
55
61
C
The maximum depth of the firebox
22
22
D
The height of the firebox opening
32-/8
38-7/8
E
The width of the firebox opening
39-7/8
45-7/8
F
The interior depth of the firebox (not shown)
18-7/8
18-7/8
H
The height to the firebox standoffs
51-5/16
57-5/16
I
Width from the left side of the box to the centerline of vent
27-1/2
30-1/2
J
Depth from back of box to centerline of top vent
6-7/8
6-7/8
K
Height from the bottom of the box to the gas line opening
15-1/8
15-1/8
L
Depth from the front of the box to gas line opening
5
5
M
Depth from rear of box to gas line opening
17
17
N
Glass height
31-1/8
37-1/8
O
Glass width
37
43
P
Depth from front of box to centerline of vent
15-3/16
15-3/16
Q
Distance from floor to fireplace opening
2
2
R
Height from floor to vent collar
38-3/4
44-3/4
N/A - Not applicable for this unit.