26996-7-0411
Page 6
SpECIFICATIONS
Dv25IN33L MODELS
Lp
Nat
Input Btu/hr Maximum
25,000
25,000
Btu/hr Minimum
17,000
17,000
KWH (Maximum)
7.30
7.30
(Minimum)
5.00
5.00
Orifice
#53 (0.0596)
#42 (0.0935)
Air Shutter Opening
Full Open
1/8”
Dv33IN33L MODELS
Lp
Nat
Input Btu/hr Maximum
33,000
33,000
Btu/hr Minimum
25,000
23,000
KWH (Maximum)
9.57
9.57
(Minimum)
7.30
6.67
Orifice
1.65 mm
#36 (0.1065)
Air Shutter Opening
Full Open
5/16”
Dv35IN33L MODELS
Lp
Nat
Input Btu/hr Maximum
35,000
35,000
Minimum
27,000
25,000
KWH (Maximum)
10.15
10.15
(Minimum)
7.83
7.30
Orifice
#51 (0.067)
#33 (0.113)
Air Shutter Opening
Full Open
3/16”
Venting Kits
Description
Contents
DVKI
Vertical Vent Kit - 17 1/2’ One piece of 35’ FlexVent (split for 17 1/2’ vent run), Round Cap, Flashing, connectors,
and clamps.
Recommended when installing to an existing round fireplace chimney pipe.
DVVK3FV
Vertical Vent Kit - 25’
Two pieces of 25’ FlexVent, Rectangle Cap, Flashing, connectors, and clamps
Recommended when installing to a square or rectangular clay flue.
DVK35
Vent Extension Kit
35’ flex vent extension section with 2 connectors and 4 clamps
NOTICE:
When installing vent caps, special locally made flashings may be required to properly seal the vent system to the existing
chimney termination.
Remote Control
Accessories
Description
FRBC
Millivolt Battery Remote ON/OFF
FRBTC
Millivolt Battery Remote Thermostat
TRW
Millivolt WIRELESS Wall Thermostat
TMV
Millivolt Reed Switch Wall Thermostat
FWS-1
Millivolt Wall Switch
Surround Kits
Description
4 Sided Contemporary - Stainless Steel Top & Bottom,
Black Sides
S2562BLSS
Stainless Steel, Black, for use on DVL25IN
models
S3362BLSS
Stainless Steel, Black for use on DVL33IN
models
4 SidedTraditional Black
S2562BL
Black for use on DVL25IN models
S3362BL
Black for use on DVL33IN models
SH-1-BL
Shroud (For fireplace openings up to 48” x 36” -
Requires surround.)