6. Begin installing the left blower assembly into the bottom of
the fireplace. Once the blower is about half way in, secure
wiring within the white plastic wire retention clips provided in
the fireplace.
See Figure 4.
Figure 4
7. Finish installing the left blower so that the left edge of the
blower base bracket is about even with the left edge of the
access opening. Route the wiring away from the blower
wheel.
See Figure 5.
Figure 5
8. Next, install the right hand blower assembly towards the
right side of the access opening. The right hand edge of the
blower base bracket should be about even with the right
edge of the access opening. Route wiring away from the
blower wheel.
See Figure 6.
Figure 6
9.
Snap the wire harness into the white plastic wire retention clip
located at the center bottom of the fireplace.
See Figure 7.