ELECTRICAL CONNECTIONS
CAUTION
All wiring should be done by a qualified electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that the main power supply is disconnected. The fireplace,
when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (Latest Edition).
A factory installed junction box is located on the lower right
side of the fireplace. Wiring must be fed to the junction box and
attached to the receptacle that is provided. Leave approximately
6in of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
See Figure 19.
BLACK (HOT)
BRASS SCREWS
JUNCTION BOX
GROUND
SILVER SCREWS
GREEN SCREW
WHITE
(NEUTRAL)
120 VOLT POWER SUPPLY
Figure 19
Install the receptacle into the junction box. Attach cover plate.
After the wiring is completed to the junction box and receptacle,
install the junction box to the lower right side of the fireplace as
shown in
Figure 20
. Insert the top flange of the retainer bracket
into the slot on the fireplace. Rotate the junction box assembly
downward, and secure with a screw below the junction box.
See Figure 20.
Control Module Access:
To access the control module for servicing, remove the barrier
screen and glass door assemblies. The control module is located
in the bottom right side opening. Remove (1) #10 x 1/2 hex
head. Screws that secures the control cover, then shift the cover
to the left and upward to remove. The control module is located
to the fireplace bottom with Velcro ®, adn can be lifted up to
access the module wiring connections.
Figure 20