Important Information 
 

Read the instructions before installing or using this appliance. 

Children should be supervised to ensure that they do not play with the appliance. 

These instructions are only valid if the country symbol appears on the appliance. If the symbol does not 

appear on the appliance, it is necessary to refer to the technical instructions which will provide the 

necessary instructions concerning modification of the appliance to the conditions of use of the country. 

 

Installation 

 

 

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) 

and the adjustment of the appliance are compatible.

 

 

 

The adjustment conditions for this appliance are stated on the label (or data plate). 

 

This appliance is not connected to a combustion products evacuation device. It shall be installed 

and  connected  in  accordance  with  current  installation  regulations.  Particular  attention 

shall  be 

given to the relevant requirements regarding ventilation. Read the instructions before installing or 

using this appliance.

 

 

The  appliance  and its individual  shut-off  valve must  be  disconnected  from the gas  supply  piping 

system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).   

 

The appliance must be isolated from the gas supply piping system by closing its individual manual 

shut-off valve during any pressure testing of the gas supply piping system at test pressures equal 

to or less than 1/2 psi (3.5 kPa). 

 

Always  check  for  the  validity  of  the  pressure  regulator.  Technical  specification  of  the  pressure 

regulator: 

i. 

Refer to TECHNICAL DATA in this manual. 

ii. 

Max. consumption: 2.5kg/h

.

 

iii. 

Should be certified according to ANSI Z21.1 / CSA 1.1 and comply with local code.   

 

This appliance must be installed and serviced by a competent person 

 

This appliance shall be installed in accordance with the regulations in force and only used in a well- 

ventilated space. 

 

Remove all packaging before using the gas cooktop 

 

Ensure that the gas and complies with the type stated on the rating label 

 

Do not attempt to modify the gas cooktop in any way 

 

For your Safety   

 

 

This gas cooktop is designed to be operated by adults. Do not allow children to play near or with 

the gas cooktop.   

 

The gas cooktop gets hot when it is in use. 

 

Children should be kept away until it has cooled. 

 

Children can also injure themselves by pulling pans or pots off the gas cooktop.   

 

CAUTION: 

This appliance is for cooking purposes only.    It must not be used for other purposes,  for 

example, room heating.

 

 

Summary of Contents for EMPV-30GC37

Page 1: ... Distributed by Empava Appliances Inc Add 15253 Don Julian Rd City of Industry CA 91745 USA www empava com Tel 888 682 8882 Email support empava com The instructions shall be marked with directions to the installer to leave them with the appliance and to the consumer to retain them for future reference ...

Page 2: ...may be achieved by having the plug accessible or by incorporating a switch in the fixed wiring in accordance with the wiring rules WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Page 3: ...ated space Read the instructions before installing or using this appliance The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or in Canada the Natural Gas and Propane Installation Code CSA B149 1 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes ...

Page 4: ...ry burner E 6000Btu hr Operating Instructions Knob 1 is for semi rapid burner D Knob 2 is for auxiliary burner E Knob 3 is for rapid burner C Knob 4 is for rapid burner B Knob 5 is for wok burner A 1 Wok burner A 18000Btu hr 2 Rapid burner B 12000Btu hr 3 Rapid burner C 12000Btu hr 4 Semi rapid burner D 9500Btu hr 5 Auxiliary burner E 6000Btu hr Operating Instructions Knob 1 is for semi rapid burn...

Page 5: ... any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Always check for the validity of the pressure regulator Technical specification of the ...

Page 6: ...r drops from blocking the air outlet and unable to ignite In case of overflow of the pot stop using the cooktop and clean the overflow before using If there are other abnormalities please contact professional maintenance person Service The gas cooktop should only be repaired or serviced by an authorized Service person and only genuine approved spare parts should be used Environmental Information A...

Page 7: ...rn off the burner control and do not attempt to re ignite the burner for at least 1 min CAUTION Accessible parts may be hot when the cooktop is in use Young children should be kept away As shown in Figure 4 place the burner onto the burner base one by one and stuck rotate left and right to check if the burners are in place the burner is placed correctly when it cannot be rotated Finally center pla...

Page 8: ...d deform see below figures for correctly placing the burner caps Figure 5 Re ignition If the flame goes out for some reasons the re igniter device will automatically start the ignition function and will not stop the ignition until the burner ignites If the burner is not ignited turn the switch to the off state and check whether there is gas in the gas pipe Under normal air supply turn the switch t...

Page 9: ...ulties and check that the burner crown holes are not obstructed Recommended maintenance instructions we recommend cleaning every six months 1 Keep the electrical area clean and free of combustible materials gasoline and other flammable gas and liquids 2 Does not hinder the flow of combustion and ventilation air 3 Visually inspect the flame of the fire transmission trough and have an icon A Take of...

Page 10: ...er cleaning The gas ring burns unevenly Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown have been replaced correctly e g after cleaning Instructions for the Installer Overall dimensions Model No Width Depth EMPV 30GC37 EMPV 30GC38 29 92in 20 08in EMPV 36GC36 36 02in 20 67in Cut out dimensions Model No Width Depth EMPV 30GC37 EMPV 30G...

Page 11: ...he rear edge of the cooktops and the wall A minimum distance of 3 94 must be left between the side edges of the cooktops and any adjacent cabinets or walls The minimum distance combustible material can be fitted above the cooktops in line with the edges of the cooktops is 18 If it is fitted below 18 a space of 1 97 must be allowed from the edges of the cooktops The minimum distance combustible mat...

Page 12: ...fective ventilation for example increasing the level of mechanical ventilation where present WARNING The base of the appliance should be protected from contact by a horizontal partition or plate A manual valve be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance Warning Turn the knob counterclockwise to ...

Page 13: ...use fire All cord connected appliances shall include instructions relative to location of the wall receptacle and a warning to the user to disconnect the electrical supply before servicing the appliance Socket needs to be installed below the cooktop surface and away from the fire source Gas Conversion Operating Instructions Figure 8 Gas type LPG NG Nozzles Dia mm Power Btu hr Nozzles Dia mm Power ...

Page 14: ... inlet pressure of 11 in w c 2740Pa coat the nozzle joints and the gas pressure regulator joints with moderate amounts of soapy water there shall be no bubbling 5 Place the burner burner cap check if the position between the ignition pin and the burner is correct and then open the valve AC model plugged in the power plug 6 Test the outlet pressure the pressure is required to be 10 1in w c If it ca...

Page 15: ...sily accessible for the engineer in the event of a breakdown WHEN THE GAS COOKTOP IS FIRST INSTALLED Once the gas cooktop has been installed it is important to remove any protective materials which were put on in the factory Any gas installation must be carried out by a competent person Important When installing the gas cooktop above a built in oven the oven should be placed on two wooden strips i...

Page 16: ...rried out by a qualified electrician or competent person Electrical supply type AC The GAS COOKTOP MUST BE EARTHED If the cooktops to be connected to a 120V 60 Hz AC electrical supply Before switching on make sure the electricity supply voltage is the same as that indicated on the cooktops rating label Ensure that the cooktops supply cable does not come into contact with surfaces with temperatures...

Page 17: ...Circuit Diagram Figure 12 for the appliance with five burners 16 ...

Page 18: ...gnature above acknowledges that I have read fully understand and accept this limitedwarranty agreement Must return within 14 days of purchase with copy of dated register receipt WARRANTY CARD COPY For your records Empava Appliances Inc Warranty Registration Dept 15253 Don Julian Rd City of Industry CA 91745 Product Model Number Name _________________________________________ Date of Purchase ______...