CG Drives & Automation, 01-6142-01r2
Menu List
71
9.
Menu List
On our home page in the download area, you could find a
"Communication information" list and a list to note Parameter
set information.
Some menus are marked with grey, see below, these menus are
so called “Advanced menus”:
To access the advanced menus, press
and
buttons
simultaneously for 3 seconds. It is also possible to go to menu
“[21E] MenuMode” and select FLD Advanced.
3A24
BEP start
No
Factory setting
Customer
100
Preferred View
110 1st Line
Sump level
120 2nd Line
Frequency
130 3rd Line *
Current
140 4th Line *
VSD status
150 5th Line *
DC Voltage
160 6th Line *
IGBT Tmp
170 View mode *
200
Main Setup
210 Operation
211
Language
English
212
Select Motor
M1
213
Drive Mode
V/Hz
214
Ref Control
Flow ctrl
215
Run/Stp Ctrl
Flow ctrl
216
Reset Ctrl
Rem+Keyb+Co
m
218
Lock Code?
0
219
Rotation
R+L
21A
Level/Edge
Level
21B
Supply Volts
Not Defined
21C
Supply Type
AC supply
21D
Drive Appl.
Waste water
21E
MenuMode
Basic
21F
CopyToFlw
Off
21G
Autotoggle
21G1 Start delay
0s
21G2 Toggle Time
5s
220 Motor Data
221
Motor Volts
U
NOM
V
222
Motor Freq
50Hz
223
Motor Power
(P
NOM
) kW
224
Motor Curr
(I
MOT
) A
225
Motor Speed
(n
MOT
) rpm
226
Motor Poles
4
227
Motor Cos
ϕ
Cos?
NOM
228
Motor Vent
Self
229
Motor ID-Run
Off
22A
Motor Sound
F
22E
Motor PWM
22E1 PWM Fswitch 3.00 kHz
22E2 PWM Mode
Standard
22E3
PWM Ran-
dom
Off
22H
Phase order
Normal
230 Mot Protect
231
Mot I
2
t Type
Trip
232
Mot I
2
t Curr
100%
233
Mot I
2
t Time
60s
234
Thermal Prot
Off
235
Motor Class
F 140
°
C
236
PT100 Inputs
PT100 1+2+3
237
Motor PTC
Off
240 Set Handling
241
Select Set
A
242
Copy Set
A>B
243
Default>Set
A
244
Copy to CP
No Copy
245
Load from CP
No Copy
250 Autoreset
251
No of Trips
10
252
Overtemp
Off
253
Overvolt D
Off
254
Overvolt G
Off
255
Overvolt
6s
256
Motor Lost
Off
257
Locked Rotor
Off
258
Power Fault
Off
259
Undervoltage
6s
25A
Motor I
2
t
60s
25B
Motor I
2
t TT
Trip
25C
PT100
Off
25D
PT100 TT
Trip
25E
PTC
Off
25F
PTC TT
Trip
25G
Ext Trip
Off
25H
Ext Trip TT
Trip
25I
Com Error
Off
25J
Com Error TT
Trip
25K
Min Alarm
Off
25L
Min Alarm TT
Trip
25M Max Alarm
Off
25N
Max Alarm TT
Trip
25O
Over curr F
Off
25Q
Over speed
Off
25R
Ext Mot Temp
Off
25S
Ext Mot TT
Trip
25T
LC Level
Off
25U
LC Level TT
Trip
260 Serial Com
261
Com Type
RS232/485
262
RS232/485
2621 Baudrate
38400
2622 Address
1
263
Fieldbus
2631 Address
62
2632 PrData Mode Basic
2633 Read/Write
RW
2634 AddPrValues
0
264
Comm Fault
2641 ComFlt Mode Off
2642 ComFlt Time
0.5 s
Factory setting
Customer
*) Only valid for the 4-lines display.
Summary of Contents for FLD48-003-54
Page 2: ......
Page 4: ......
Page 8: ...4 CG Drives Automation 01 6142 01r2...
Page 30: ...26 Installation CG Drives Automation 01 6142 01r2...
Page 56: ...52 EMC and standards CG Drives Automation 01 6142 01r2...
Page 74: ...70 Technical Data CG Drives Automation 01 6142 01r2...
Page 82: ...78 Menu List CG Drives Automation 01 6142 01r2...
Page 83: ......