Troubleshooting

If problems occur, the first step should be to verify that the Fusion Flex Amplifier is set to the 

proper line voltage for your AC power source, and that your power source is operating correctly.

Problem: No sound is heard from either channel (the Standby LED is not lit).

Reason: You have no AC power.

• 

Verify that the circuit is live and the rear panel Power switch is On.

• 

Verify that the line cord on the Fusion Flex Amp is fully inserted and is tight.

Problem: No sound is heard from either channel (the Standby LED is lit red).

Reason: The Fusion Flex Amp is in Standby mode.

• 

If the Fusion Flex Amp is in “On” power mode, press the Standby button.

• 

If the Fusion Flex Amp is in “Trigger” power mode, verify that a trigger signal is present.

• 

If the Fusion Flex Amp is in “Auto” power mode, verify that audio signal is present at an input.

• 

Send a Power On command via IR or RS-232 remote control.

Problem: No sound or distorted sound is heard from one or both channels 
(the Status LED is lit blue).

Reason: The Fusion Flex Amp is On and is not indicating a fault.

• 

Verify that the correct input is selected.

• 

Verify that the Volume is not all the way down.

• 

Check your source and your input cabling.

• 

Check your speakers and speaker connections.

Problem: No sound is heard (the Standby LED is flashing red).

Reason: The Fusion Flex Amp is indicating a fault on one or both channels.

• 

Verify that the speaker cable(s) and speaker terminals are not shorted.

• 

Verify that the speaker itself is not shorted or damaged 

(try the speaker on another channel and see if the fault “moves”).

• 

Verify that the source is not faulty  

(try that input cable on another input and see if the fault “moves”).

• 

Disconnect all inputs and outputs and reset the Fusion Flex Amp 

(turn the rear panel Power rocker switch Off and back On).

Problem: The Volume control doesn’t respond to the front panel buttons or the  
IR remote, but everything else is working correctly.

Reason: The Fusion Flex Amplifier’s Volume Lockout feature is engaged.

• 

Press and hold the front panel Input 1 button for about three seconds to disengage the 

Volume Lockout feature.

Summary of Contents for Fusion Flex

Page 1: ......

Page 2: ......

Page 3: ...vice personnel Do not install the Fusion Flex Amplifier near or above any heat sources such as radiators heating vents or other apparatus that produce heat Do not block any ventilation openings or hea...

Page 4: ...r Fusion Flex Amplifier by qualified service personnel if any of the following occur 1 The power supply cord or the plug has been damaged 2 Objects or liquid have fallen or spilled into the vents 3 Th...

Page 5: ...fier Front Panel 7 Fusion Flex Amplifier Remote Control 8 Fusion Flex Amplifier Rear Panel 9 Inputs and Outputs 11 Installation Tips 12 Configuration 13 Operation 14 Care and Maintenance 16 Performanc...

Page 6: ...Page 2 Fusion Flex Amplifier...

Page 7: ...or using the standard trigger input or it can be set to switch on automatically when it senses an audio signal The digitally controlled analog volume control offers precise control near perfect channe...

Page 8: ...ifier We suggest that you read through the entire manual we kept things as short and direct as possible Even if you re an expert user you will probably find some interesting information and useful sug...

Page 9: ...y controlled analog volume control for precisely repeatable control and superb channel tracking Two stereo inputs with manual or automatic input switching Manual triggered or automatic power switching...

Page 10: ...Gently remove your Fusion Flex Amplifier from the packing carton and remove all wrappings and shipping material It is important to save the box and all packing materials in case your power amp ever ne...

Page 11: ...essing Auto instructs the Fusion Flex Amp to use whichever input has active audio signal on it If both inputs are active Input 1 has priority When each input mode is selected the corresponding LED wil...

Page 12: ...Button Pressing 1 or 2 manually selects that input pressing the Auto Button instructs the Fusion Flex Amp to use whichever input has active audio signal on it If both inputs are active Input 1 has pr...

Page 13: ...s accept bare wires spade lugs and banana plugs 5 Power Switch Switches the AC mains power to the Fusion Flex Amplifier On and Off When this switch is Off the Fusion Flex Amplifier will not respond to...

Page 14: ...r between On and Standby 9 IR Input Connect an external IR sensor to this input if the Fusion Flex Amplifier is mounted such that IR remote control signals cannot reach the front panel directly 10 Pow...

Page 15: ...to Trigger Input RS 232 serial input output on rear panel 9 pin d connector female Front panel controls and indicators Standby large push button toggles Standby mode Standby LED 1 red for Standby mod...

Page 16: ...ngaged by pressing the front panel Input 1 button and holding it for approximately 3 seconds THIS LOCKOUT MODE WILL REMAIN IN EFFECT EVEN IF THE FUSION FLEX AMP IS SET INTO STANDBY MODE OR POWERED OFF...

Page 17: ...toggles between Standby and operating On modes each time it is pressed When the Power Mode switch is set to Auto the Fusion Flex Amp is controlled by audio input the Fusion Flex Amp switches On when...

Page 18: ...t after a short delay if the Power Mode switch is in Auto mode the Standby button on the IR remote is pressed or the code is received from a compatible control the Power Off command is received from a...

Page 19: ...button is pressed and move smoothly up or down if the appropriate button is held down When under the control of an RS 232 serial controller the level may be either moved up or down or set to an expli...

Page 20: ...sion Flex Amp should be cleaned gently with a soft rag If something sticky gets on the front panel or case of the Fusion Flex Amp it should be cleaned with a mild cleaning solution applied to a soft r...

Page 21: ...dB A weighted Frequency response 20 Hz to 20 kHz 0 08 dB Trigger and control Trigger Input 5 20 VAC or VDC Serial Standard RS 232 drive levels Protection The Fusion Flex Amplifier is protected against...

Page 22: ...is heard from one or both channels the Status LED is lit blue Reason The Fusion Flex Amp is On and is not indicating a fault Verify that the correct input is selected Verify that the Volume is not al...

Page 23: ...What will Emotiva do Emotiva will at its option either i repair the product or ii replace the product with a new consumer product which is identical or reasonably equivalent to the product Emotiva ma...

Page 24: ...ide you with a returned material authorization number RMA 3 Ship the product to Emotiva at the following address with the RMA written in large bold numbers on the outside of the box and with the lette...

Page 25: ...anual is accurate to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of o...

Page 26: ...Emotiva Audio Corporation 135 Southeast Parkway Court Franklin TN 37064 emotiva com...

Reviews: