background image

Page 14

Fusion Flex Amplifier

Operation

Turning on the AC power

The AC mains power on the Fusion Flex Amplifier is controlled by the Power rocker switch located 

on the rear panel above the power cable. When the AC mains power is Off, the Fusion Flex Amp 

will not respond to any command (but it will remember Volume and Input settings.) Once the  

AC power is turned on, the Fusion Flex Amp will remain in Standby mode until:

• 

the Standby push button on the front panel is pressed.

• 

the Trigger Input is asserted (if the Power Mode switch is in Trigger mode).

• 

audio signal is sensed at an input (if the Power Mode switch is in Auto mode).

• 

the Standby button on the IR remote is pressed  

(or the code is received from a compatible control).

• 

the Power On command is received from an RS-232 serial device.

The PA 2-50 will then remain On until:

• 

the Standby push button on the front panel is pressed again.

• 

the Trigger Input is dropped (if the Power Mode switch is in Trigger mode).

• 

audio signal is no longer sensed at an input - after a short delay  

(if the Power Mode switch is in Auto mode).

• 

the Standby button on the IR remote is pressed  

(or the code is received from a compatible control)

• 

the Power Off command is received from an RS-232 serial device.

The Power Mode switch is the small bat switch on the rear panel labelled “On/Auto/Trigger”.

Status Indicators

When the Fusion Flex Amp is in Standby mode, the single LED next to the front panel Standby 

switch will be lit red; when the Fusion Flex Amp is On, the LED will be lit blue; if a fault occurs, the 

LED will flash red (and all other LEDs will be off).

Selecting an Input

To select in input using the front panel controls, press one of the Input Selector buttons  

(1, 2, or Auto). Pressing 1 or 2 directly selects that input; pressing Auto configures the Fusion 

Flex Amp to use whichever input is active. If both inputs have audio signal on them, Input 1 

takes priority and will be selected. If only a single input is to used, it should be Input 1. The same 

input commands may be received via the included IR remote control, a programmable IR remote 

configured with the correct codes, or a remote control device connected to the RS-232 serial port 

on the rear panel of the Fusion Flex Amp. 

Summary of Contents for Fusion Flex

Page 1: ......

Page 2: ......

Page 3: ...vice personnel Do not install the Fusion Flex Amplifier near or above any heat sources such as radiators heating vents or other apparatus that produce heat Do not block any ventilation openings or hea...

Page 4: ...r Fusion Flex Amplifier by qualified service personnel if any of the following occur 1 The power supply cord or the plug has been damaged 2 Objects or liquid have fallen or spilled into the vents 3 Th...

Page 5: ...fier Front Panel 7 Fusion Flex Amplifier Remote Control 8 Fusion Flex Amplifier Rear Panel 9 Inputs and Outputs 11 Installation Tips 12 Configuration 13 Operation 14 Care and Maintenance 16 Performanc...

Page 6: ...Page 2 Fusion Flex Amplifier...

Page 7: ...or using the standard trigger input or it can be set to switch on automatically when it senses an audio signal The digitally controlled analog volume control offers precise control near perfect channe...

Page 8: ...ifier We suggest that you read through the entire manual we kept things as short and direct as possible Even if you re an expert user you will probably find some interesting information and useful sug...

Page 9: ...y controlled analog volume control for precisely repeatable control and superb channel tracking Two stereo inputs with manual or automatic input switching Manual triggered or automatic power switching...

Page 10: ...Gently remove your Fusion Flex Amplifier from the packing carton and remove all wrappings and shipping material It is important to save the box and all packing materials in case your power amp ever ne...

Page 11: ...essing Auto instructs the Fusion Flex Amp to use whichever input has active audio signal on it If both inputs are active Input 1 has priority When each input mode is selected the corresponding LED wil...

Page 12: ...Button Pressing 1 or 2 manually selects that input pressing the Auto Button instructs the Fusion Flex Amp to use whichever input has active audio signal on it If both inputs are active Input 1 has pr...

Page 13: ...s accept bare wires spade lugs and banana plugs 5 Power Switch Switches the AC mains power to the Fusion Flex Amplifier On and Off When this switch is Off the Fusion Flex Amplifier will not respond to...

Page 14: ...r between On and Standby 9 IR Input Connect an external IR sensor to this input if the Fusion Flex Amplifier is mounted such that IR remote control signals cannot reach the front panel directly 10 Pow...

Page 15: ...to Trigger Input RS 232 serial input output on rear panel 9 pin d connector female Front panel controls and indicators Standby large push button toggles Standby mode Standby LED 1 red for Standby mod...

Page 16: ...ngaged by pressing the front panel Input 1 button and holding it for approximately 3 seconds THIS LOCKOUT MODE WILL REMAIN IN EFFECT EVEN IF THE FUSION FLEX AMP IS SET INTO STANDBY MODE OR POWERED OFF...

Page 17: ...toggles between Standby and operating On modes each time it is pressed When the Power Mode switch is set to Auto the Fusion Flex Amp is controlled by audio input the Fusion Flex Amp switches On when...

Page 18: ...t after a short delay if the Power Mode switch is in Auto mode the Standby button on the IR remote is pressed or the code is received from a compatible control the Power Off command is received from a...

Page 19: ...button is pressed and move smoothly up or down if the appropriate button is held down When under the control of an RS 232 serial controller the level may be either moved up or down or set to an expli...

Page 20: ...sion Flex Amp should be cleaned gently with a soft rag If something sticky gets on the front panel or case of the Fusion Flex Amp it should be cleaned with a mild cleaning solution applied to a soft r...

Page 21: ...dB A weighted Frequency response 20 Hz to 20 kHz 0 08 dB Trigger and control Trigger Input 5 20 VAC or VDC Serial Standard RS 232 drive levels Protection The Fusion Flex Amplifier is protected against...

Page 22: ...is heard from one or both channels the Status LED is lit blue Reason The Fusion Flex Amp is On and is not indicating a fault Verify that the correct input is selected Verify that the Volume is not al...

Page 23: ...What will Emotiva do Emotiva will at its option either i repair the product or ii replace the product with a new consumer product which is identical or reasonably equivalent to the product Emotiva ma...

Page 24: ...ide you with a returned material authorization number RMA 3 Ship the product to Emotiva at the following address with the RMA written in large bold numbers on the outside of the box and with the lette...

Page 25: ...anual is accurate to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of o...

Page 26: ...Emotiva Audio Corporation 135 Southeast Parkway Court Franklin TN 37064 emotiva com...

Reviews: