![Emos ZS2911 Manual Download Page 3](http://html1.mh-extra.com/html/emos/zs2911/zs2911_manual_2402620003.webp)
3
min. 1 m
200 mm
min. 90˚
max. 50˚
GB | LED Floodlight SMD + PIR SENSOR
LED reflector is designed for indoor and outdoor use to be
mounted on a firm ground.
Ingress Protection: IP54 – for outdoor use
PIR sensor – specification:
Time-delay: min. 10 s ±5 s – max. 10 min ±1 min
Detection angle: 120°
Ambient light: 5 lux –> 2 000 lux (adjustable)
Detection distance: 5–10 m
Detection motion speed: 0.6–1.5 m/s
PIR sensor setting:
Detection field is possible to be set by moving the motion
sensor switch to the left and to the right.
Adjustment of the ambient light (sensitivity)
You can choose at what luminosity will the sensor go on by
a button A (see picture no. 4).
Time-delay
You can set the time-delay of the lamp by a button B (see
picture no. 4)
Detection range
The distance at which the sensor responds to movement can
be set using the control C.
Mounting
Mount the lamp firmly onto a solid basis, for example a wall
(fig. 1, 2, 3).
Installation height 2.3–3 m.
Connect a power cable for connection to a 220–240 V~
power network.
The cable must not be plugged into the power network during
installation of the spotlight.
Direct the reflector as shown on fig. 1 and 2.
L – brown – live wire
G – green&yellow – earth wire (ground)
N – blue – neutral wire
Maintenance instructions:
Before maintenance, switch off the lamp and wait until it
is cooled.
Clean it with a soft moistened cloth.
Never submerge the lamp in water or other liquids.
During maintenance, observe general rules for occupational
safety, and be very careful.
WARNING
• The reflector is designed entirely for firm mounting.
• Before connecting to the 220–240 V~ make sure that the
connecting wire is not under voltage. This operation can
be carried out only by an authorized person.
• Respect a minimum distance of 1 m between the appli-
ance and the object or surface which you wish to lighten.
• If you place the reflector below the roof, keep the min-
imum 0.2 m distance measured from the upside of the
reflector to the bottom of the roof.
• Do not use the reflector without the protection glass.
• The protection from dangerous contact voltage is ensured
by „earthing“.
• The external flexible cable or cord of this luminaire cannot
be replaced; if the cord is damaged, the luminaire shall
be destroyed.
• The lights source of this luminaire is not replaceable; when
the light source reaches its end of life the whole luminaire
shall be replaced.
• Terminal block not included. Installation may require
advice from a qualified person.