2. WARNINGS

 

 

 

 

Spe-

gnere

HIGHLY 
FLAMMABLE GAS
ONLY FOR 
EXTERNAL UNIT 
R32

MEANING OF SYMBOLS

indicates a prohibited action.

Indicates that important instructions must be followed.

Indicates a part which must be grounded.

2.1   Attention and dangers

Before using the air conditioner please read carefully the instructions 

manual. Producer decline every responsibility for any damage caused by 

the non-observing of the following warnings. 

When this manual has been read, please make sure that further unit users 

will read it as well.

User has to keep this manual close to hand and has to give it to those who 

repair and move the unit. Furthermore when there is an owner change, 

please let the manual at disposal of the new user. Please make sure that 

the following important safe information are strictly observed.

Unit is not intended to be used by persons with reduced physical, sensory or mental abilities, or with lack of 

experience or acknowledge (children included) unless they had the possibility to benefit of some monitoring or 

using instructions through a person responsible for their safety. Children have to be monitored to be sure they do not 

play with the unit. This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision 

or instruction concerning use of the appliance in a safe way and understand the hazards involved. children shall not 

play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. caution: 

do not expose the electronics of your charging and drying stand or the battery charger. There are no user serviceable 

parts inside. Tefer servicing to qualified service personnel. please ensure voltage rating for enclosed battery charger 

matches standard outlet voltage.

Do not install the air conditioner in rooms where gas leakages or 

other flammable substances could occur near the units.

Maintenance operations must be carried out exclusively by quali-

fied technicians.

Do not use the emergency button with wet hands.

Do not place flower vases or water containers on the unit.

Verify the air conditioner’s wall attachments firmness. 

Do not place objects or stand on the unit.

Do not direct the air flow directly on individuals, plants or animals.

Don’t blow the human body with the cooling air too long, and don’t 

let the room  temperature decrease too low either.  Otherwise the 

one will feel unpleasant or harm ones’ health.

Do not disassemble the louver of the external unit. Fan exposure is 

very dangerous, it could hurt people .

Summary of Contents for XEVO-0917-M3E

Page 1: ...Air Conditioner Serie XEVO XX17X3E R32 Outdoor Unit INSTALLATION MANUAL AND USING INSTRUCTIONS INSTALLATION MANUAL AND USING INSTRUCTIONS GB GB...

Page 2: ...ecifications and all the information useful for the correct functioning The information contained in this publication may be subject to changes at any time and without any notice whatsoever for techni...

Page 3: ...the units 5 6 Dimensions of the indoor unit 6 EXTERNAL UNIT INSTALLATION 13 6 1 External unit installation 6 2 Outdoor unit condensation drain pipe 6 3 Refrigerating circuit piping 6 4 Electrical sup...

Page 4: ...tion 4 Refrigerating pipe connection 1 4 Product identification table Throughthefollowingtableyoumayidentifythemake upoftheairconditioner Type Power in kBtu h Set UI UE Unit Outdoor Unit Indoor Single...

Page 5: ...rom 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appl...

Page 6: ...dangerous and can cause injury Do not pour or spray water on the air conditioner Do not install the air conditioner near sources emitting excessive vapours moisture oils etc Please use fuses with the...

Page 7: ...dos otocolo di Kyoto No vierta este tipo de gas a la atmosfera Produkt enth lt fluorierte Treibhausgase ch das Kyoto Protokoll abgedeckt werden n Sie Gase nicht in die Atmosph re ab duit contient des...

Page 8: ...re fighting procedures In the event of a fire stop the leak if it is not dangerous Do not extinguish the flames on the leak because there is the possibility of an uncontrolled explosive re ignition Sp...

Page 9: ...ty Inhalation Product difluoromethane LC 0 Rat 4 h 520000 ppm Remarks Gas ECOLOGICAL INFORMATION Bioaccumulation potential Product The product is expected to be biodegradable and it is not expected to...

Page 10: ...h Places with acid or alkaline fumes TV radio acoustic equipment have to remain at a minimum distance of 1 m from the internal unit the external unit the power supply cables pipes otherwise images co...

Page 11: ...d with siphon A D E C B 1 2 1 2 Outdoor Unit Indoor Unit A mm B mm C mm D mm E mm 300 600 300 2000 600 5 3 Distance between the units 5 2 Minimum operational distances OUTDOOR UNIT A Indoor Unit B B M...

Page 12: ...ns of the indoor unit C E H B D A Model E mm D mm H mm C mm A mm B mm XEVO 0917 M3E R32 770 322 555 840 487 298 XEVO 1217 M3E R32 770 322 555 840 487 298 XEVO 1817 D3E dual 800 365 554 860 514 340 XEV...

Page 13: ...s of the companies and of the personnel about fixed units of refrigeration air condition and heating pumps which contain some fluorinated greenhouse gases according to the Regulation EC nr 842 2006 of...

Page 14: ...the CU DHP for UNI EN 12735 1 type The copper pipe for plumbing services is not suitable Refrigerating lines Path and bending of pipelines Define the pipeline path with the fewest possible bends Bend...

Page 15: ...d end and the fitting before they are joined This precaution prevents possible gas leakage Attention Use only synthetic oil in air conditioners which are charged with R 32 refrigerant Inclined profile...

Page 16: ...te core Power supply Power supply of the units For al models power supply is moved to external unit Power supply Magnetothermic switch Please use an exclusive source of electrical power for the air co...

Page 17: ...N S 1 S B N B L B L 1 L S W 2 N 1 L S W 2 N 1 L S W 2 N Signal N L Signal N L Not used Ferrite core Power supply Ferrite core Ferrite core Ferrite core Ferrite core Unit A Power supply 1 L S W 2 N 1 L...

Page 18: ...the same Note the coolant must not be released into the atmosphere as specified in the regulation CE no 2037 2000 of the European Parliament and of the Council 6 EXTERNAL UNIT INSTALLATION 7 CHARGE A...

Page 19: ...then check that the vacuum in the system has been maintained If not look for the cause of the leak For pipelines longer than 5 meters it is necessary to fill the circuit using a measuring cylinder or...

Page 20: ...efrigerant it contains requires a special procedure for dis posal Materials of value in the air conditioner can be recycled Contact local authorities or the waste disposal facility for more informatio...

Page 21: ...nser T3 disconnected short circuit F3 T5 short circuit disconnection temperature sensor F4 External drive EEPROM error F5 External fan speed out of control PO IPM module malfunction or IGBT module ove...

Page 22: ...unit exchanger output temperature E T2B E 22 Ambient Indoor Unit Temperature A T1 A If the temperature is below 9 C 9 will still be displayed If the temperature is above 70 V 70 will still be displaye...

Page 23: ...T4 Compressor Exhaust Temperature Sensor T5 9 FUNCTIONAL ANOMALIES 42 Active Frequency Limitations Bit7 Frequency limit caused by IGBT radiator The displayed value is the hex number For exam ple disp...

Page 24: ...8 244 0 37956 1 30 37 1988 39 102 5 39689 79 174 1 2133 119 246 0 36954 0 32 35 2024 40 104 5 17519 80 176 1 17393 120 248 0 35982 1 34 33 3269 41 106 4 96392 81 178 1 13604 121 250 0 35042 2 36 31 56...

Page 25: ...241 2 357 3 27 211 4 37 99 32 94 77 171 7 566 117 243 2 294 2 28 200 7 38 100 31 62 78 172 7 321 118 244 2 233 1 30 190 5 39 102 30 36 79 174 7 086 119 246 2 174 0 32 180 9 40 104 29 15 80 176 6 859...

Page 26: ...oor unit 9 12kBtu Yellow Green Optional Yellow Green Blue Yellow Green Blue Brown Red Yellow Green Indoor Unit Power supply 4 Way Valve Heater Compressor Heater Basement Fan DC Blue Red Black Compress...

Page 27: ...temperature sensor Exchanger evaporator Unit A BLUE RED BLACK VALVE EXPANSION ELECTRONICS Valve 4 WAY Heater Compressor Power supply COMPRESSOR Unit B Heater Basement YELLOW GREEN EVA T2B EVA T2B 88 S...

Page 28: ...A core for each indoor unit power cord 4 Way Valve Heater basement Yellow Green WHITE WHITE 4 way Heat 1 Heat 2 Red Black Yellow Green Brown Blue Black Brown fan DC COMPRESSOR BLUE RED BLACK BLUE Rea...

Page 29: ...ure sensor T5 Compressor discharge temperature sensor INDOOR UNIT OUTDOOR UNIT T2 Evaporator temp sensor Liquid side 2 way valve T3 Condensator Temperature sensor T4 Outdoor ambient Condensator Exchan...

Page 30: ...uid Valve A Liquid Valve B T3 Condensator temperature sensor Gas Valve A Gas Valve B 4 way valve T5 Discharge temperature sensor COOLING HEATING Exchanger heat condensator T4 Ambient Temperature senso...

Page 31: ...A Gas Valve B Gas Valve C Expansion valve electronics Heat Exchange capacitor COOLING HEATING T5 Discharge temperature sensor 4 way valve Accumulator Compressor R32 TRIAL INDOOR UNIT OUTDOOR UNIT Hea...

Page 32: ...E Fontanafredda Pn Italy XEVO 0917 M3E 58 XEVO 0917 W43 53 6 1 149 2 6 4 0 875 2 5 0 2 R32 675 675 675 None 2 3 Fontanafredda Pn Italy XEVO 1217 M3E 60 XEVO 1217 W43 54 6 1 195 3 4 4 1 1093 3 2 0 2 R3...

Page 33: ...y XEVO 1817 D3E 61 XEVO 0917 W43 54 7 2 253 5 2 4 0 1680 4 8 1 0 R32 675 675 675 None XEVO 1217 W43 3 9 A Fontanafredda Pn Italy XEVO 2717 T3E 66 54 7 2 399 8 2 4 1 2390 7 0 0 1 R32 675 675 675 None X...

Page 34: ......

Page 35: ...reet Zip Town Country Slip A for user To be kept Please print in block letters GUARANTEE CERTIFICATE Slip A GUARANTEE CERTIFICATE Slip B GUARANTEE CERTIFICATE Slip C Model Serial Number Date installat...

Page 36: ...send part C in a closed envelope to Emmeti Spa post box nr 74 Fontanafredda PN within ten days from the date of installation first startup Should the certificate not be sent within 10 days of the ins...

Page 37: ......

Page 38: ...38 Note...

Page 39: ...39 Note...

Page 40: ...Vigonovo PN Italy Tel 0434 567911 Fax 0434 567901 Internet http www emmeti com E mail info emmeti com Rev 0 07 2017 AM Respect the environment For a correct disposal the different materials must be di...

Reviews: