1. INTRODUCTION TO THE PRODUCT

1.7  External unit

 

Air outlet grille

 

Air inlet grille

 

Door to electrical connection

 

Refrigerant pipe connections

1.8  Product identification table

Through the following table you may identify the make-up of the air 

conditioner.

1

   

Display temperature:

 

- In AUTO mode, COOL and HEAT are displayed

 

  The temperature set;

 

- The temperature is displayed in the FAN and DRY modes

           Of the internal environment.

3

4

90

B2

61.5 A2

12 A1

R6

90

B2

61.5 A2

12 A1

R6

2

1.5  Internal unit display

Type

Power 

in 

kBtu/h

Set 

UI+UE

Unit 

Outdoor

Unit

Indoor

Single 

Hi-Wall

9

XEVO-0917 R32 XEVO-0917-M3E

XEVO-0917W43

Single 

Hi-Wall

12

XEVO-1217 R32 XEVO-1217-M3E

XEVO-1217W43

Dual 

Hi-Wall

18

XEVO-1817 

DR32

XEVO-1817-D3E

XEVO-0917W43 / 

XEVO-1217W43

Trial 

Hi-Wall

27

XEVO-2717 

TR32

XEVO-2717-T3E

XEVO-0917W43 / 

XEVO-1217W43 / 

XEVO-1217W43

1.6   Accessories supplied with the internal unit

Description

Q.ty

Remote control 

1

2cm

30cm

30cm

1.5m

30cm

30cm

1.5m

Remote control  support

1

2cm

30cm

30cm

1.5m

30cm

30cm

1.5m

batteries

2

2cm

30cm

30cm

1.5m

30cm

30cm

1.5m

Template for fixing

1

Fillers for liquid and gas pipes

1

Installation and using manual of 

the internal unit

1

Summary of Contents for XEVO-0917 M3E

Page 1: ...Air Conditioners Serie XEVO XX17W43 WALL INSTALLATION MANUAL AND USING INSTRUCTIONS FOR INTERNAL UNIT INSTALLATION MANUAL AND USING INSTRUCTIONS FOR INTERNAL UNIT GB GB...

Page 2: ...pecifications and all the information useful for the correct functioning The information contained in this publication may be subject to changes at any time and without any notice whatsoever for techn...

Page 3: ...ackaging 11 4 Battery disposal 12 ELECTRIC SCHEMES 36 WARRANTY 37 1 INTRODUCTION TO THE PRODUCT 4 1 1 Introduction to the conditioning 1 2 Refrigeration circuit 1 3 Air conditioner composition 1 4 Int...

Page 4: ...Condensation Room air is pushed from a fan through a second heat exchanger called condenser internal unit in Heating mode Refrigerant gas at high pressure and temperature condensate giving heat to th...

Page 5: ...90 B2 61 5 A2 12 A1 R 6 2 1 5 Internal unit display Type Power in kBtu h Set UI UE Unit Outdoor Unit Indoor Single Hi Wall 9 XEVO 0917 R32 XEVO 0917 M3E XEVO 0917W43 Single Hi Wall 12 XEVO 1217 R32 X...

Page 6: ...from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the app...

Page 7: ...dangerous and can cause injury Do not pour or spray water on the air conditioner Do not install the air conditioner near sources emitting excessive vapours moisture oils etc Please use fuses with the...

Page 8: ...ado con efecto invernadero incluidos di Kyoto No vierta este tipo de gas a la atmosfera t enth lt fluorierte Treibhausgase Kyoto Protokoll abgedeckt werden ase nicht in die Atmosph re ab tient des gaz...

Page 9: ...ERS Special fire fighting procedures In the event of a fire stop the leak if it is not dangerous Do not extinguish the flames on the leak because there is the possibility of an uncontrolled explosive...

Page 10: ...et Acute toxicity Inhalation Product difluoromethane LC 0 Rat 4 h 520000 ppm Remarks Gas ECOLOGICAL INFORMATION Bioaccumulation potential Product The product is expected to be biodegradable and it is...

Page 11: ...ations have to be done carefully because the external part of the units has not to be damaged when knifes or cutters are used to open the carton package After unpacking make sure of the unit integrity...

Page 12: ...ration in the air c Near resurgences with high content of sulphuric gases d In areas with high tension fluctuation e g factories etc e In vehicles or boats 5 1 Indoor unit positioning Avoid sources of...

Page 13: ...ositioning in correspondence with areas that can worsen the negative effects of atmo spheric agents such as eaves drains or downpipe drains Select the position that is favourable for air circulation a...

Page 14: ...m 09 717 302 193 12 805 302 193 W D H Hole for tube Inner unit line Hole for tube Hole for tube Inner unit line Hole for tube 452 7 mm 406 4 mm 249 mm 153mm 39mm 65mm 54mm 102mm 805 mm 65mm 302mm 409m...

Page 15: ...ulation EC Nr 303 2008 which provides the minimum requirements of the companies and of the personnel about fixed units of refrigeration air condition and heating pumps which contain some fluorinated g...

Page 16: ...e installation template Move the unit from one side to another to verify that all has been fixed safely Fig N Fig N Fixing template In order to fix the body onto the mounting template hold up the body...

Page 17: ...shing on the curvatures Fix the pipe to the drain and block it with a clamp band Insulate with an insulated sheath of 9mm thickness the whole pipe inside the house to avoid drip as a consequence of an...

Page 18: ...al appliances to work 6 6 2 Power supply of the units For al models power supply is moved to external unit Power supply Magnetothermic switch 6 6 3 Connection and alimentation cables All the feed and...

Page 19: ...ation piping and wrap with reinforced tape possibly alluminized If the cable cannot be solid with the piping make a suitable wall ancho rage by means of a cable fastener or hose clips 6 8 Connections...

Page 20: ...N 1 L S W 2 N Signal N L Signal N L Not used Ferrite core Power supply Ferrite core Ferrite core Ferrite core Ferrite core Unit A Power supply 1 L S W 2 N 1 L S W 2 N Unit A Unit B Unit B Unit C L N L...

Page 21: ...FP key Short Press Silence Operation Activation Long press FP function activation TIMER ON ON key Key for selecting programmed startup of the air conditioner TIMER OFF OFF key Key for selecting progr...

Page 22: ...tion is active Temperature C Time H 6 Automatic Cooling Dehumidification Heating Ventilation 7 1 2 How to insert batteries in the infrared remote control The infrared remote control is powered by two...

Page 23: ...If the remote control is installed on the wall it should be close to the indoor unit The remote control should not be Allowed to get wet Dropped Exposed to the direct sun light Exposed to heating sou...

Page 24: ...peration With the buttons TEMP Set the desired temperature in the room 17 30 C The temperature can be set to grade degree Pressing the button FAN Select the desired fan speed Low Medium High Auto Nota...

Page 25: ...idity is high dew accumulates on the external unit which reduces air conditioner performances To prevent this performances reduction air conditioner is equipped with an automatic defrosting system set...

Page 26: ...SWING and DIRECT function can be used with all the air conditioner s operating modes and determines the vertical motion of the air deflector thus obtaining an even distribution of the air in the room...

Page 27: ...d select the mode of operation desired 2 Press this button TIMER OF several times to set how long the unit should turn on The time set in the first 10 hours increases by 1 2 hour at each pres sure the...

Page 28: ...al unit display shows SC during the operation At the end of this 16 minute cycle the unit goes to OFF You can force the shutdown at any time by pressing the SELF CLEAN button again 8 AIR CONDITIONER U...

Page 29: ...on The Autorestart function allows automatic ignition of the air conditioner In the event of a sudden power failure the air conditioner will resume working with the same settings prior to interruption...

Page 30: ...imer effectively If the air conditioner is not used for a long period of time disconnect the electrical power supply via the switch located up the line from the system not included Use the deflectors...

Page 31: ...with water and alcohol at a temperature not exceeding 40 C Dry with a soft cloth Never use fuel chemical solvents detergent and or abrasive powders furniture cleaning spray sandpaper or rough cloths t...

Page 32: ...he air conditioner using the remote control 9 5 Condensation water dry check When using the air conditioner in the summer time check that the conden sation water is drained correctly from the indoor u...

Page 33: ...he air conditioner not cool sufficiently Are the indoor unit air filters dirty or clogged Is the outdoor unit grid clogged Is there an open window Is the temperature on the remote control set regularl...

Page 34: ...ited EC Observe coolant leaks F0 Overcurrent Protection F1 Outdoor temperature sensor T4 disconnected or short circuited F2 Exchanger temperature sensor condenser T3 disconnected short circuit F3 T5 s...

Page 35: ...contains requires a special procedure for dis posal Materials of value in the air conditioner can be recycled Contact local authorities or the waste disposal facility for more information Make sure yo...

Page 36: ...CN41 ALARM CN45 wired remote control REMOTE ON OFF Electrical diagram Internal unit 9 12 kBtu FAN MOTOR Deflector Motor White Red Blu Black Yellow Yellow Green Internal Unit Main Board Optional Contr...

Page 37: ...reet Zip Town Country Slip A for user To be kept Please print in block letters GUARANTEE CERTIFICATE Slip A GUARANTEE CERTIFICATE Slip B GUARANTEE CERTIFICATE Slip C Model Serial Number Date installat...

Page 38: ...send part C in a closed envelope to Emmeti Spa post box nr 74 Fontanafredda PN within ten days from the date of installation first startup Should the certificate not be sent within 10 days of the ins...

Page 39: ......

Page 40: ...aly Tel 0434 567911 Fax 0434 567901 Internet http www emmeti com E mail info emmeti com Rev 0 07 2017 Ufficio Tecnico Emmeti Spa AM Respect the environment For a correct disposal the different materia...

Reviews: