65
1. DESCRIZIONE DEI COMPONENTI
GB
GB
8. USE THE AIR CONDITIONER
Timer ON Hour flashes, press
to set desired hour,
(at each press the time will increase or decrease by 1 minute)
After having set the switch-on time (Timer ON Hour), press the
"ENTER" button to set the minutes (Timer ON Minutes). After set-
ting the minutes (Timer ON Minutes), press the "ENTER" button to
switch to the off-time setting (Timer OFF).
Proceed in the same way to set the OFF Timer (Hour and Minutes).
If it is not necessary to set the Timer OFF, press the "CANCEL"
button to cancel.
After completing the Timer ON / OFF setting, press
to select
the desired day, press the "ENTER" button to confirm or press
"CANCEL" to cancel.
The selected day will be marked with "•".
For exemple, figure
,shows 7 days of week, all
selected.
After setting the switch-on and switch-off on the desired days
of the week for Programming 1, press Timer / Clock to switch to
Programming 2.
Repeat the same steps already described for Programming 1.
Up to a maximum of 4 weekly switch-on / switch-off programs can
be predefined.
To exit the Weekly Timer setting by pressing "TIMER / CLOCK" or
"ON / OFF" when the programming number is flashing.
8.12 Temperature displayed on display
By default the display shows the set temperature.
To view the room temperature on the LCD display, press the " " and
"
ENTER
" button simultaneously for 3 seconds; the buzzer emits 4
beeps confirming that the operation has been performed.
On display appears symbol
and display room temperature.
To cancel setting, press the " " " and "
ENTER
" button simultaneously
for 3 seconds, disappears
and is displayed set temperature on
display.