91
1. DESCRIZIONE DEI COMPONENTI
GB
GB
10. ANOMALIES AND FUNCTIONING
10.1 Messages shown on the display of the indoor unit
The 7 segments display of the indoor unit, automatically displays the error code when the
unit has the following problem
Legend
Light
Flash
OFF
ERROR
CODE
Power
Timer
Running
Sleep
Content
1
2
3
4
EA
The error code is displayed when there are problems in the communication between the
display board and the control board.
When the unit has the following problem and the compressor stops working, press the SLEEP button on the remote control for 10 times within 10 seconds and
7 segments display will show error code indicated below. If there are two malfunctions at the same time, once the first error is entered, it is necessary to press
the SLEEP button for 10 times, LED will show the other error code.
SLEEP
TIMER
RUNNING
ERROR CODE
CONTENT (GB)
0
Normal
1
The failure for temperature sensor of outdoor coil
2
Compressor exhaust temperature sensor in trouble
5
IPM module protection
6
AC voltage higher or lower protection
7
Communication failure between the indoor unit and outdoor unit
8
Current overload protection
9
Maximum current protection
10
Communication trouble between outdoor unit and driver
11
Outdoor EEPROM in trouble
12
Outdoor ambient temperature too low protection
13
Compressor exhaust temperature too high protection
14
Outdoor ambient temperature sensor in trouble
15
Compressor shell temperature too high protection
16
Anti-freeze protection with cooling or overload protection with heating in
17
PFC protection
18
DC compressor start failure
19
Compressor drive in trouble
20
Outdoor fan motor locked rotor protection
21
Outdoor coil anti-overload protection with cooling
22
Compressor pre heating process
24
Chip in outdoor board in trouble
26
Overheated outdoor radiator
27
Protection against too high system pressure
33
The failure for temperature sensor of indoor room
34
The failure for temperature sensor of indoor coil temperature
36
Communication failure between the indoor unit and outdoor unit
38
Indoor EEPROM failure
39
Indoor fan motor run abnormally
41
The failure for Indoor grounding protective
Summary of Contents for X-REV0-1219W
Page 16: ...16 IT IT 5 POSIZIONAMENTO DELLE UNITÀ Destro Sinistro modello 18 kBtu ...
Page 17: ...17 IT IT 5 POSIZIONAMENTO DELLE UNITÀ modello 18 kBtu ...
Page 18: ...18 IT IT 5 POSIZIONAMENTO DELLE UNITÀ Destro Sinistro modello 24 kBtu ...
Page 19: ...19 IT IT 5 POSIZIONAMENTO DELLE UNITÀ modello 24 kBtu ...
Page 50: ......