28

Parameter 

CHANNEL-1 PROPORTIONAL

Address

42031

CHANNEL-2 PROPORTIONAL

42043

CHANNEL-3 PROPORTIONAL

42055

CHANNEL-4 PROPORTIONAL

42067

Parameter

CHANNEL-1 INTEGRAL

Address

42032

CHANNEL-2 INTEGRAL

42044

CHANNEL-3 INTEGRAL

42056

CHANNEL-4 INTEGRAL

42068

Parameter

CHANNEL-1 DERIVATIVE

 Address

42033

CHANNEL-2 DERIVATIVE

42045

CHANNEL-3 DERIVATIVE

42057

CHANNEL-4 DERIVATIVE

42069

Parameter

CHANNEL-1 OUT PERIOD

Address

42040

CHANNEL-2 OUT PERIOD

42052

CHANNEL-3 OUT PERIOD

42064

CHANNEL-4 OUT PERIOD

42076

Parameter

CHANNEL-1 OUT MINIMUM

Address

42037

CHANNEL-2 OUT MINIMUM

42049

CHANNEL-3 OUT MINIMUM

42061

CHANNEL-4 OUT MINIMUM

42073

Parameter

CHANNEL-1 OUT MAXIMUM

Address

42038

CHANNEL-2 OUT MAXIMUM

42050

CHANNEL-3 OUT MAXIMUM

42062

CHANNEL-4 OUT MAXIMUM

42074

PID Proportional Parameters 
Modbus Addresses

PID Integral Parameters 
Modbus Addresses

PID Out Minimum Parameters 
Modbus Addresses

PID Out Period Parameters
Modbus Addresses

PID Derivative Parameters
Modbus Addresses

PID Out Maximum Parameters 
Modbus Addresses

*

( )

*

( )

*

( )

*

( )

*

( )

*

( )

*

( )

*

( )

*

( )

*

( )

*

( )

*

( )

         These parameters are displayed on LCD screen with point, so that the parameters values 
         are 10 times than the real values for  modbus function. 

*

( )

ii

If no operation is performed for 20 seconds in technician parameters section, device turns to 
main operation screen automatically.

ii

Summary of Contents for PID QUADRO EPLC9600

Page 1: ...rol parameter which can be adjust for each day of week or via front panel buttons or via digital inputs Adjustable temperature offset for each channel 3 Different alarm types for each channel High Low...

Page 2: ...ained Operation Also in these sections there are warnings to prevent serious injury while doing the physical and electrical mounting or using the device Explanation of the symbols which are used in th...

Page 3: ...ERS 6 1 DEFINETION OF FRONT PANEL 6 2 MAIN OPERATION SCREEN DEFINETION 6 3 ACCESSING TO THE OPERATOR PARAMETER PAGES 6 4 ACCESSING TO THE TECHNICIAN PARAMETER PAGES 6 5 ACCESSING TO THE CALIBRATION PA...

Page 4: ...EC The Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4 2007 EMC Generic Emission Standard...

Page 5: ...ich they are used are below Application Fields Applications Glass Heating Plastic Baking Ovens Petro Chemistry Incubators Textile Storages Automative Storages Machine production industries etc etc 1 P...

Page 6: ...the standards A 1 Supply Voltage A 2 9 Customer 100 240V V 15 10 50 60Hz 24VV 15 10 50 60Hz 24VZ 15 10 1 3 Warranty EMKO Elektronik warrants that the equipment delivered is free from defects in mater...

Page 7: ...eep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit...

Page 8: ...9600 PID QUADRO Front View and Dimensions of 96 mm 3 78 inch 96 mm 3 78 inch 12 1 mm 0 47 inch 84 mm 3 31 inch Maximum 15 mm 0 59 inch Front Panel IP65 protection NEMA 4X Panel surface maximum thickne...

Page 9: ...2 3 Panel Cut Out 9 129 mm 5 08 inch min 92mm 3 62 inch 92mm 3 62 inch 129 mm 5 08 inch min...

Page 10: ...etal panel care should be taken to avoid injury from metal burrs which might be present The equipment can loosen from vibration and become dislodged if installation parts are not properly tightened Th...

Page 11: ...re that device will not fall while doing the montage 2 6 Installation Fixing Clamp The unit is designed for panel mounting 1 Insert the unit in the panel cut out from the front side 2 Insert the mount...

Page 12: ...e unit against damage and to prevent failure Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented 3 Electrical Wirings 3 1 Terminal...

Page 13: ...NERAL ALARM OUT 5 x 5A 250VV USB 2 0 COMMUNICATION ETHERNET OR RS485 COMMUNICATION For Channel 1 2 3 and 4 PID Control Outputs Relay Outputs i i For Channel 1 2 3 and 4 Alarm Outputs and General Alarm...

Page 14: ...supply voltage input Power supply switch and fuse must be put to a place where user can reach easily Power supply switch must be two poled for seperating phase and neutral On Off condition of power s...

Page 15: ...t 2000V V Relay Outputs Digital Inputs 2000V V 2000V V 2000V V 14 15 AIN1 AIN2 AIN3 AIN4 500V V 2000V V 2000V V AIN2 AIN1 AIN3 AIN4 500V V 2000V V 2000V V AIN3 AIN1 AIN2 AIN4 500V V 2000V V 2000V V AI...

Page 16: ...puter 9 Pin DCON connection Cable Lenght must be max 12 meters for 9600 baud rate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 TX NA RX GND NA NA 4 Cable Connection...

Page 17: ...used Cable lenght can be maximum 1000 meters in 9600 baud rate When baud rate increases cable lenght must be decreased 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Page 18: ...and entering the symbol character for string type variables in variable value changing screen DOWN BUTTON This button is used to decrement the digit which cursor is show of variable in variable value...

Page 19: ...EEN 1 Press escape button for returning main operation screen 1 i i MAIN OPERATION SCREEN 2 Device Working Mode 6 2 Main Operation Screens Definition If more than one alarm messages is present each al...

Page 20: ...he password parameter Minimum Maximum 0 9999 0 0 Press enter button for accessing to password entering screen Enter the operator parameter section password with cursor lef right up and down buttons OP...

Page 21: ...ge the parameter value with cursor lef right up and down buttons Press number 1 2 3 or 4 buttons for accessing the relevant channel s parameter screen OPERATOR PARAMETER SCREEN CHANNEL 2 PARAMETERS Ot...

Page 22: ...r button for accessing to password entering screen Enter the technician parameter section password with cursor lef right up and down buttons TECHNICIAN PARAMETERS SECTION PASSWORD ENTERING SCREEN TECH...

Page 23: ...ed for 20 seconds in technician parameters section device turns to main operation screen automatically Press number 1 2 3 or 4 buttons for accessing the relevant channel s parameter screen Press down...

Page 24: ...tton for accessing next parameter page press up button for accessing previous parameter page Press up button for accessing previous parameter page press escape button for return to main operation scre...

Page 25: ...Maximum 0 9999 0 CALIBRATION PASSWORD MAIN OPERATION SCREEN CALIBRATION PARAMETERS SECTION PASSWORD SCREEN Press right or left button for selecting the password parameter Press enter button for access...

Page 26: ...y observed Parameter CHANNEL 1 PROCESS SET Address 42030 CHANNEL 2 PROCESS SET 42042 CHANNEL 3 PROCESS SET 42054 CHANNEL 4 PROCESS SET 42066 Parameter Address CHANNEL 1 ALARM SET 42078 CHANNEL 2 ALARM...

Page 27: ...put 100 0 0 OUT MAXIMUM PID Maximum Control Output 100 sec sec sec 1 150 1 0 100 Min Max Unit DERIVATIVE PID derivative value for selected channel is can be adjusted according to this parameter It can...

Page 28: ...CHANNEL 2 OUT MINIMUM 42049 CHANNEL 3 OUT MINIMUM 42061 CHANNEL 4 OUT MINIMUM 42073 Parameter CHANNEL 1 OUT MAXIMUM Address 42038 CHANNEL 2 OUT MAXIMUM 42050 CHANNEL 3 OUT MAXIMUM 42062 CHANNEL 4 OUT...

Page 29: ...nished without any problem device saves new PID parameters to memory and the tune parameter value is to 0 automatically If parameter value 0 Tune off 1 Auto tune Limit CycleTuning operation 2 Self tun...

Page 30: ...39 CHANNEL 2 SOFT START 42051 CHANNEL 3 SOFT START 42063 CHANNEL 4 SOFT START 42075 Parametre CHANNEL 1 ALARM TYPE Address 42079 CHANNEL 2 ALARM TYPE 42083 CHANNEL 3 ALARM TYPE 42087 CHANNEL 4 ALARM T...

Page 31: ...tering to the technician section is defined with this parameter If it is 0 technician section accessed without entering password OPER PASS Password for entering to the operator section is defined with...

Page 32: ...8 CHANNEL 2 PV OFFSET 42099 CHANNEL 3 PV OFFSET 42100 CHANNEL 4 PV OFFSET 42101 Alarm Hysteresis Parameters Modbus Addresses Alarm Bandwith Parameters Modbus Addresses Proses Offset Value Parameters M...

Page 33: ...n Channel Names I O PID Operation Type Selection Parameter If parameter value 0 PID function is disabled 1 Heating PID function is selected 2 Cooling PID function is selected PID operation type is sel...

Page 34: ...and auto eco mode is active for selected day of week then auto eco mode starting minute is determined by this parameter TIME If MODE CONTROL parameter value selected as 3 auto mode control is active...

Page 35: ...Auto ECO Mode Parameters for THURSDAY THURSDAY ECO MODE SET DIFF 42148 FRIDAY ECO Address 42153 FRIDAY ECO MODE STARTING HOUR 42154 FRIDAY ECO MODE STARTING MINUTE 42155 FRIDAY ECO MODE TIME 42156 Au...

Page 36: ...0 auto SLEEP MODE is disable for selected day of week 1 auto SLEEP MODE is enable for selected day of week MODE START HOUR If MODE CONTROL parameter value selected as 3 auto mode control is active and...

Page 37: ...NG MINUTE WEDNESDAY SLEEP MODE TIME Auto SLEEP Mode Parameters for WEDNESDAY THURSDAY SLEEP THURSDAY SLEEP MODE STARTING HOUR THURSDAY SLEEP MODE STARTING MINUTE THURSDAY SLEEP MODE TIME Auto SLEEP Mo...

Page 38: ...S232 is can be adjusted by this parameter If parameter value ID Modbus communication device ID for RS232 is can be adjusted by this parameter This parameter value is can be adjusted from 1 to 247 exce...

Page 39: ...by this parameter If parameter value ID Modbus communication device ID for RS485 is can be adjusted by this parameter BAUDRATE Baudrate For RS485 Communication 42110 6 1 2 PARITY Parity For RS485 Comm...

Page 40: ...mple When the analogue values are recorded on USB file user can be save the recording time on the file Recording time is recorded at the beginning of every lines of file SAMPLE TIME Record time interv...

Page 41: ...be adjusted by this parameter If DHCP is selected as a enable there is no need to adjust to this parameter if DHCP is selected as a disable then user must adjust this parameter PORT SET Ethernet port...

Page 42: ...ameter SECOND Second value for RTC time is adjusted by this parameter Min Max Default Unit YEAR Year Value For RTC Time 3000 2010 MONTH Month Value For RTC Time 12 1 Parameter Explanation DAY Day Valu...

Page 43: ...m Output Process Value Alarm Output SET HYS SET HYS ON OFF Alarm Output Process Value BandAlarm SET SET BAND 2 SET BAND 2 HYS HYS SET Alarm Set value HYS Hysteresis value forAlarm output BAND Bandwidt...

Page 44: ...Input values can be readed with modbus function 4 read input register Because of the process values are displayed on LCD screen with point the reading values from modbus will be 10 times more than th...

Page 45: ...Sensor Break Protection Upscale Sampling Time 1400msecs Input Ressistance 10MW Control Forms Programmable P PI PD or PID Relay Output Resistive Load 5A 250VV Electrical Life 100 000 operation Full Lo...

Reviews: