
50
Unit selection
Unit is °C
Unit is °F
Process
Set value
mV
Z
50
0-50 mV
Z
range are divided into 16 egual parts. Every “Poxx” SET value is defined
50 / 16 = 3.125 mV
Z
range.
Po00 = 0
Po01
Po02
Po03
Po04
Po05
Po16
Po06
Po15
Po07
Po08
Po09
Po10
3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125 3.125
3.125
6.25
9.375
12.5
15.625 18.75 21.825
25
28.125 31.25 34.375
37.5
40.625 43.75 46.875
Po14
Po13
Po12
Po11
Minimum value of operating scale. It can be changed according to input
type and scale of the process.
Maximum value of operating scale. It can be changed according to
input type and scale of the process.
Display offset for process value. It can be adjusted -10% to +10% of
scale. The defined value is added to process value.
Defines filter time for input signal. It can be adjusted from 0.0 to 900.0.
It is active if process input is selected TC input. It decides if cold
junction compensation is active or not.
Cold junction compensation is active.
Cold junction compensation is not active.
Coefficient value for
Z
Voltage / Current input. Process value is
multiplied with this value.
It is active if
Z
Voltage / Current input is selected. It can be adjusted
from 1.000 to 9.999.
Unit is U. It is active if
Z
Voltage / Current input is selected
No unit. It is active if
oltage / current input is selected
Z
V