5.2 Alarm Output Graphics of ESM-3722
i
=
Process Set Value (Temperature or Humidity)
Process High Alarm
ON
OFF
Alarm
Output
Process Value
Alarm Set
Process Low Alarm
ON
OFF
Alarm
Output
Process Value
Deviation Range Alarm
ON
OFF
Alarm
Output
Process Value
( - Alarm Set)
( +Alarm Set)
Deviation Band Alarm
ON
OFF
Alarm
Output
( - Alarm Set)
Alarm Set
( +Alarm Set)
Process Value
5.3 Egg Tray Rotator Operation Graphics of ESM-3722
Egg Tray Rotator
Output
Led
Egg Tray Rotator
Output
1-
connection. While this message shown on this display,if buzzer function selection is 3, 5, 7 or 8
internal buzzer starts to operate.
Screen Blinking Temperature Sensor failure . Sensor connection is wrong or there is no sensor
5.4 Failure Messages in ESM 3722 Hatcher Controller
2
Screen Blinking H
Sensor failure . Sensor connection is wrong or there is no sensor
connection. While this message shown on this display,if buzzer function selection is 4, 6,7 or 8
internal buzzer starts to operate.
-
umidity
3- In main operating screen if the upper display is blinking, it means that temperature alarm exits and
alarm output is active .if buzzer function selection is 1, 5 or 8 internal buzzer starts to operate.
4- In main operating screen if the lower display is blinking, it means that humidity alarm exits and alarm
output is active .if buzzer function selection is 2, 6 or 8 internal buzzer starts to operate.
5- Self Tune temperature error. Appears on the main screen.this fault occurs when the
temperature read from the sensor is closer to the Process Set value than 5% of the scale(5 ° C for the
ProNem Mini PMI-P sensor). Self tune operation is not allowed.