6.4.12.3 FEEDING SYSTEM (EPC 3&4)
FEEDING PARAMETERS PAGES have two different screens. These screens depend on
CONTROL FUNC PAGE 1 PAGE
CURVE parameter.
At the same time only one of these pages is used by EPC. In addition this, both pages has the same feature.
If
CONTROL FUNC PAGE 1 PAGE
CURVE parameter is OFF all time the same parameters values which are
in the FEEDING PARAMETERS are used. Otherwise the values are calculated by EPC depend on
FEEDING PARAMETERS CURVE STEP pages.
FEEDING PARAMETERS
CURVE STEP X
F1: 00:00 0
F2: 00:00 0
F3: 00:00 0
F4: 00:00 0
F5: 00:00 0
HR:MN FEED<KG>
Start Time
Feed Amount
FEEDING PARAMETERS
F1: 00:00 0
F2: 00:00 0
F3: 00:00 0
F4: 00:00 0
F5: 00:00 0
HR:MN FEED<KG>
Start Time
Feed Amount
MONITORING FEEDING DATA
Feeding data can be monitored via FEEDING CONSUMPTION page.
This page is explained at user section.
FEEDING SYSTEM
There could be two different feeding system.
- The system with loadcell
- The system without load cell
Depend on system selection EPC uses two different calculation method, to decide what method will use,
FEED UNIT PARAMETERS PAGE
UNIT parameter is used.
If there is a loadcell in the system, EPC uses FEEDING ANALOG input but if there is no loadcell in the system
then EPC uses time and
FEED UNIT PARAMETERS PAGE
FEED PER MIN parameter to calculate for
feeding consumption. Both system are more explained with examples in next pages.
STARTING OF THE NEW STEP
EPC captures time and compares it and step times continuously. If there is an equality between time and any
step’s time then that step will run.
FEEDING CONSUMPTION
10.08.07 13:44:45
TARE : NO
RESET CONSUM: NO
REQUIREDFEED: 0KG
EXIST FEED : 151KG
TOTAL CONSUM: 20450KG
DAY NUMBER : 1
FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE : NO
REF WEIGHT : 250KG
TAKE REF WEIGHT: NO
FEED OFFSET : 0KG
68