FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE : NO
REF WEIGHT :
KG
TAKE REF WEIGHT: NO
FEED OFFSET : 0KG
500
FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE :
REF WEIGHT : 250KG
TAKE REF WEIGHT: NO
FEED OFFSET : 0KG
NO
FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE : NO
REF WEIGHT : 500KG
TAKE REF WEIGHT:
FEED OFFSET : 0KG
NO
FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE :
REF WEIGHT : 250KG
TAKE REF WEIGHT: NO
FEED OFFSET : 0KG
YES
FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE : NO
REF WEIGHT : 500KG
TAKE REF WEIGHT:
FEED OFFSET : 0KG
YES
FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE : NO
REF WEIGHT : 500KG
TAKE REF WEIGHT:
FEED OFFSET : 0KG
NO
6.4.12.2 FEEDING WEIGH ADJUSTMENT (EPC 3&4)
1. Feeding adjustment steps:
FEED UNIT PARAMETERS page’s have three parameters are used to
make feeding adjustment.
1. Take tare (TARE parameter),
2. Enter reference weight (REF WEIGHT parameter),
3. Take reference weight (TAKE REF WEIGHT parameter).
Example;
Access to FEED UNIT PARAMETERS page.
Push three times button to access to TARE parameter
While the silo is empty push button to switch parameter’s value to
YES.
Almost 3 seconds later read weight is saved as tare weight and parameter’s
value will switch back to NO. Now push button and access to next
parameter. Using button enter 500 kg and push button.
Put 500 kg feed into silo (because of reference weight is 500 kg for this
example).
Wait for a little time for feed weigh reading stabilisation and
push button to switch parameter to YES.
Almost 3 seconds later feed weigh is saved as reference weight and
parameter’s value switches back to NO.
FEED UNIT PARAMETERS
UNIT : WEIGHT
FEED PER MIN: 1.0KG
TARE : NO
REF WEIGHT : 250KG
TAKE REF WEIGHT: NO
FEED OFFSET : 0KG
67