background image

TB-6584

 Page 1 of 13

© 2016 DESCO INDUSTRIES, INC.

Employee Owned

SmartLog V5™

Installation, Operation and Maintenance

Description

The patented* EMIT SmartLog V5™ system is designed 

for fast, frequent, and accurate testing of ESD personnel 

grounding items.  Its unique design embeds an ESD 

tester, time clock, keypad, barcode scanner, Ethernet 

module and proximity badge reader (optional) into a 

compact stainless steel enclosure.
By touching the solid-state switch once, the SmartLog 

V5™ independently tests the resistance path limits of 

the worn wrist strap and both worn ESD footwear in less 

than 2 seconds.  It may also test a worn ESD garment 

if it is used as part of personnel grounding path.  Test 

results are electronically stored in the SmartLog V5™ 

and easily downloaded to a PC for logging records 

and evaluation.  This product can be used as one of 

the tools to fulfill the ANSI/ESD S20.20 section 7.3 

“Compliance Verification Plan.”
Paperless data can enhance operator accountability, 

immediately identifying problems while reducing logging 

and auditing costs.  There is no need to dedicate a 

computer for each test station.  The SmartLog V5™ is 

a complete system including all required components.  

Operator identification can be accomplished using 

the keypad, scanning a barcode badge or waving a 

proximity badge (verify compatibility with the factory).

April 2016

Figure 1.  EMIT SmartLog V5™

The SmartLog V5™ can test either single or dual-wire 

wrist straps and its split footplate design provides 

individual footwear testing all in a single test.  With 

the use of TEAM5 Software, the SmartLog V5™ can 

be programmed to assign unique test requirements to 

personnel.  An individual can be required to test either 

wrist strap only, footwear only or a combination of the 

two.
If a resistance path is below or exceeds the set limits, 

the SmartLog will indicate failure via audio and visual 

alarms.  Use the included relay terminal to promote 

access control for passed tests.
The SmartLog V5™ can also be networked to a 

company’s Intranet using its embedded Ethernet 

module.  The SmartLog V5™ is calibrated to NIST 

traceable standards.

ESD Association Information

“Compliance verification should be performed prior to 

each use (daily, shift change, etc.).  The accumulation 

of insulative materials may increase the foot grounder 

system resistance.  If foot grounders are worn outside 

the ESD protected area testing for functionality 

before reentry to the ESD protected area should be 

considered.”  ESD SP9.2 APPENDIX B - Foot Grounder 

Usage Guidance
“Process monitoring (measurements) shall be conducted 

in accordance with a Compliance Verification Plan that 

identifies the technical requirements to be verified, the 

measurements limits and the frequency at which those 

verifications shall occur...Compliance verification records 

shall be established and maintained to provide evidence 

of conformity to the technical requirements.
The test equipment selected shall be capable of 

making the measurements defined in the Compliance 

Verification Plan.” (ANSI/ESD S20.20) section 7.3 

 

ANSI/ESD S20.20 Table 1 Flooring-Footwear Systems 

Technical Requirements Recommended Range “less 

than 3.5 x 10

7

 ohms measured per ANSI/ESD STM 

97.1.”
“Typical test programs recommend that wrist straps that 

are used daily should be tested daily.  However, if the 

products that are being produced are of such value that 

knowledge of a continuous, reliable ground is needed, 

and then continuous monitoring should be considered or 

even required.”  (ESD Handbook ESD TR 20.20 section 

5.3.2.4.4)
Note: SmartLog V5™ provides wrist strap test per IEC 

61340-5-1 Clause A.1 and footwear testing per IEC 

61340-5-1 Clause A.2 with upper limits < 3.5 x 10

7

 

ohms.

  TECHNICAL BULLETIN TB-6584 

*US Patents 6,078,875 and 6,809,522

Made in the

United States of America

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for SmartLog V5

Page 1: ...mits the SmartLog will indicate failure via audio and visual alarms Use the included relay terminal to promote access control for passed tests The SmartLog V5 can also be networked to a company s Intranet using its embedded Ethernet module The SmartLog V5 is calibrated to NIST traceable standards ESD Association Information Compliance verification should be performed prior to each use daily shift ...

Page 2: ...ing 5 Features and Components 6 Installation 6 Clock Configuration 6 Tester Configuration 7 Hardware Setup 8 50771 Turnstile Bracket 10 Relay Terminal 10 Ethernet Setup 11 Direct Connection to PC 11 TEAM5 Software 12 Operation 12 Calibration 13 Specifications 13 Limited Warranty www com information itm com 1 800 561 8187 ...

Page 3: ...tLog V5 PC with TEAM5 Software Supervisor Department Manager Department Manager Department Manager Illustration of the SmartLog V5 System collecting and transferring ESD data to a central PC where it is distributed to supervisors and department managers www com information itm com 1 800 561 8187 ...

Page 4: ...V5 Turnstile 220VAC 50771 Turnstile Bracket SmartLog V5 50424 Limit Comparator for Testers Packaging SmartLog V5 Test System 1 SmartLog V5 1 Mounting Bracket 1 Dual Independent Foot Plate 1 Foot Plate Cable 6 1 Power Adapter 9VDC 1 25A center pos 1 Right Angle Ground Cord 2 Mounting Anchors 2 Mounting Screws 1 Thumb Screw 1 10mm Wrist Cord Adapter 50769 only 1 Certificate of Calibration See page 8...

Page 5: ...er from the tester K Buzzer Volume Adjustment Turn the trimpot clockwise to increase the buzzer volume and counter clockwise to decrease the volume L Foot Plate Jack Connect one end of the foot plate cable here and the other end to the dual foot plate M Test Limit DIP Switch Use this DIP switch to configure the resistance limits of the tester See Tester Configuration on page 6 for more information...

Page 6: ...owing configurations BAUD 9600 PARITY ODD SMART LOG ID 00 The SmartLog ID is a two digit field that ranges from 00 63 Each SmartLog must have a unique ID number should you have several units configured to your system DAYLIGHT DISABLE PORT EXPAND YES DECODE NO READER MAGSTRIPE 5 Press the MENU button to save and exit setup mode Tester Configuration The resistance limits for footwear and wrist strap...

Page 7: ... LEDs continue to blink inspect the foot plate cable and verify that it is securely connected at both terminals Hardware Setup If the SmartLog V5 is located near a restroom sink or other water source operators will need to be instructed to thoroughly dry their hands before testing Wet hands may cause inaccurate test results and damage to the tester 1 Use the included screws and anchors to secure t...

Page 8: ...thread 3 Washers 1 Nylon Bushing Installation 1 The 50771 Turnstile Bracket provides a way to route the SmartLog s cables through the turnstile s enclosure in order to eliminate tampering of the connections Use the drill pattern in Figure 9 to mill the top cover of your turnstile and clear space to mount the bracket Typ 120º 3X 189 R 90 875 Figure 9 Drill pattern for mounting the bracket to a turn...

Page 9: ...slots on the back of the SmartLog V5 with the hooks on the turnstile bracket Figure 13 Locating the mounting hooks on the bracket 7 Slide the SmartLog V5 into the bracket from top to bottom Secure the SmartLog V5 to the bracket by fastening the included 4 40 screw on the left side of the tester Figure 14 Sliding the SmartLog V5 into the bracket and securing it into place with the 4 40 screw slide ...

Page 10: ...ote of the MAC address of your SmartLog V5 This can be found on a label located at the bottom and right hand side of the unit 2 Verify that the Ethernet cable is securely connected to your network and SmartLog V5 The SmartLog V5 must be powered during Ethernet setup The LEDs on the Ethernet port will illuminate when a connection to the network is established 3 Use the following link to download th...

Page 11: ...ton when complete Figure 21 Directly connecting the SmartLog V5 to a PC Non inverted RS 232 cable DB9 serial adapter PC with TEAM5 Software SmartLog V5 TEAM5 Software TEAM5 is the most powerful and accurate ESD Test Acquisition Software on the market When used with the EMIT SmartLog TEAM5 allows manufacturers and assemblers to automate the collection of employee ESD testing It has a set of robust ...

Page 12: ...se pass When performing a wrist strap test be sure to completely plug in the wrist cord into the tester s jack 4 Press and hold the metal touch plate on the tester to perform the test Hold your finger on the touch plate until the results of the test are displayed If performing a wrist strap test and the wrist strap status LEDs do not illuminate verify that the wrist cord is correctly inserted into...

Page 13: ... Voltage 5 VDC open circuit Wrist Strap and Footwear Test Voltage 30 VDC open circuit Test current is limited by resistors and varies on the test range setting 100 kilohms 1 gigohm Memory Capacity2 Test ID Length Test Transactions 4 16 100 5 15 300 6 14 600 7 14 000 8 13 400 9 12 900 10 12 400 11 11 900 12 11 500 13 11 100 14 10 700 15 10 400 16 10 100 2 This only applies should the SmartLog V5 lo...

Reviews: