6. The relay terminal will activate and unlock the
turnstile if the defined tests are passed.
NOTE: Failures may be caused by dry skin or
minimal sweat layer. For wrist straps, try using an
approved dissipative hand lotion such as
Menda
Reztore™ ESD Hand Lotion
prior to use. Footwear
test results can be improved by taking a short walk
to build a sweat layer for better conductivity.
Figure 7. Performing a single-wire wrist strap test
Figure 6. Performing a footwear test
7. Pass through the turnstile. The turnstile will re-lock
after one rotation.
NOTE: By default, the turnstile will remain unlocked
until either the operator passes through or 20
seconds expire. See the “Turnstile Control Board
Layout” section in the
Alvarado EDC Installation and
Maintenance Manual
for instructions on modifying
the turnstile’s relock setting.
*The SmartLog Pro® may also be used to test smocks
or garments that feature a grounding mechanism for
operators using a coiled cord connection.