background image

TB-6596

 Page 3 of 7

© 2019 DESCO INDUSTRIES INC

Employee Owned

EMIT 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Website: 

DescoEMIT.com

Operation

NOTE: The SmartLog Pro® must first be programmed 

with the user ID table using the TEAM5 Software before 

being deployed for employee use, or the default test 

settings will be applied.
See the 

TEAM5 User Manual

 for more information.

If the SmartLog Pro® is located near a restroom, sink or 

other water source, operators will need to be instructed 

to thoroughly dry their hands before testing. Wet hands 

may cause inaccurate test results and damage to the 

tester.
1.  A circling light around the test switch indicates when 

the SmartLog Pro® is on standby and ready to 

perform a test. 

2.  Initiate the test procedure by identifying yourself to 

the SmartLog Pro®. This may be done using the 

touchscreen keypad, barcode scanner or proximity 

reader. 

 

NOTE: Hold the proximity badge in front of the RFID 

icon for a full second if using proximity badges. See 

Figure 5. 

3.  Follow the prompt on the SmartLog’s display. 
4.  When performing a footwear test, be sure to place 

both feet on the dual foot plate (one foot per plate). 

 

NOTE: Keep the foot plate clean with 99% isopropyl 

alcohol when using the 1 Gigohm high test limit. A 

dirty foot plate could yield a false pass. 

 

When performing a wrist strap* test, be sure to 

completely plug in the wrist cord into the tester’s  

jack. 

5.  To begin the test, use your finger to bridge the test 

switch’s inner and outer contacts. The blue standby 

LED will become solid to indicate that the test has 

been initiated. Hold your finger down until the test 

results are displayed on the touchscreen. 

 

If your finger is removed too early, the tester’s 

blue LEDs will blink three times to indicate that the 

test was not completed. DO NOT touch any metal 

other than the SmartLog Pro® or the turnstile while 

performing your test as this will affect your results. 

Figure 4. Using the barcode scanner

Figure 5. Holding a proximity badge in front of the RFID 

icon on the SmartLog Pro®

Summary of Contents for SmartLog Pro 50723

Page 1: ...tile The SmartLog Pro with Turnstile is available as the following item numbers Item Input Voltage 50723 100 VAC 50781 120 VAC 50782 220 VAC ESD Association Information Compliance verification should...

Page 2: ...martLog Pro onto the turnstile s lid using the 2 slanted standoffs 1 socket head cap screw and 1 internal tooth lock washer See Figure 2 NOTE This mounting is also sold separately as EMIT item 50783 I...

Page 3: ...in front of the RFID icon for a full second if using proximity badges See Figure 5 3 Follow the prompt on the SmartLog s display 4 When performing a footwear test be sure to place both feet on the du...

Page 4: ...aking a short walk to build a sweat layer for better conductivity Figure 7 Performing a single wire wrist strap test Figure 6 Performing a footwear test 7 Pass through the turnstile The turnstile will...

Page 5: ...0A Cable Length 5 ft 1 5 m Turnstile Input Voltage and Frequency 110VAC 50 60 Hz 50781 220VAC 50 60 Hz 50782 Operating Temperature 70 F to 85 F 21 C to 30 C for 1 gigohm test limit 41 F to 85 F 5 C t...

Page 6: ...INDUSTRIES INC Employee Owned EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com Figure 10 Dimensions of the EMIT SmartLog Pro with Turnstile 27 0 69 cm 9 5 24 cm 25 0 64 cm 40...

Page 7: ...980 Website DescoEMIT com Figure 11 Turnstile lid cutout dimensions for mounting the SmartLog Pro using the 50783 Turnstile Mounting Kit all dimensions are in inches Limited Warranty Warranty Exclusio...