background image

TB-6596

 Page 1 of 7

© 2019 DESCO INDUSTRIES INC

Employee Owned

EMIT 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Website: 

DescoEMIT.com

SmartLog Pro® with Turnstile

Installation, Operation and Maintenance

Description

The EMIT SmartLog Pro® with 

Alvarado EDC Waist 

High Turnstile

 verifies the functionality of an operator’s 

wrist strap and footwear, logs the test results, and 

controls access to an ESD Protected Area. The turnstile 

unlocks after the operator’s wrist strap and/or footwear 

is determined to act as a path-to-ground. All operator 

test activity is logged into a database to meet the 

ANSI/ESD S20.20 requirements for on-going quality 

control purposes. Each log entry includes operator 

identification, test results, resistance measurements, 

time, temperature and humidity.
See 

TB-6594

 for more information on the patented* 

EMIT SmartLog Pro®.
The 

Alvarado EDC Waist High Turnstile

 features a 

rugged industrial grade controller, optical rotation 

detection (no mechanical microswitches to break or 

continually adjust), and adjustable time out functionality 

(turnstile relocks if there is no passage through the 

unlocked turnstile). An adjustable dampener slows 

and cushions the rotation and self-centers the turnstile 

arms to the home position. Stainless steel internal and 

external components make the turnstile durable and 

easy to maintain.
The turnstile is configured to Fail-Safe Loss-of-Power 

Operation. Should loss of power occur, the turnstile’s 

arms will unlock and rotate freely in both directions to 

allow operators to pass through.

February 2019

Figure 1. EMIT SmartLog Pro® with Turnstile

The SmartLog Pro® with Turnstile is available as the 

following item numbers:

Item

Input Voltage

50723

100 VAC

50781

120 VAC

50782

220 VAC

ESD Association Information

“Compliance verification should be performed prior to 

each use (daily, shift change, etc.). The accumulation 

of insulative materials may increase the foot grounder 

system resistance. If foot grounders are worn outside 

the ESD protected area testing for functionality 

before reentry to the ESD protected area should be 

considered.” ESD SP9.2 APPENDIX B - Foot Grounder 

Usage Guidance
“Process monitoring (measurements) shall be conducted 

in accordance with a Compliance Verification Plan that 

identifies the technical requirements to be verified, the 

measurements limits and the frequency at which those 

verifications shall occur...Compliance verification records 

shall be established and maintained to provide evidence 

of conformity to the technical requirements.
The test equipment selected shall be capable of 

making the measurements defined in the Compliance 

Verification Plan.” (ANSI/ESD S20.20) section 7.3 

ANSI/ESD S20.20 Table 1 Flooring-Footwear Systems 

Technical Requirements Recommended Range “less 

than 3.5 x 10

7

 ohms measured per ANSI/ESD STM 

97.1.”
“Typical test programs recommend that wrist straps that 

are used daily should be tested daily. However, if the 

products that are being produced are of such value that 

knowledge of a continuous, reliable ground is needed, 

and then continuous monitoring should be considered or 

even required.” (ESD Handbook ESD TR 20.20 section 

5.3.2.4.4)
Note: SmartLog Pro® provides wrist strap test per IEC 

61340-5-1 Clause A.1 and footwear testing per IEC 

61340-5-1 Clause A.2 with upper limits < 3.5 x 10

7

 

ohms.

  TECHNICAL BULLETIN TB-6596 

*US Patent 6,809,522

Made in the

United States of America

Summary of Contents for SmartLog Pro 50723

Page 1: ...tile The SmartLog Pro with Turnstile is available as the following item numbers Item Input Voltage 50723 100 VAC 50781 120 VAC 50782 220 VAC ESD Association Information Compliance verification should...

Page 2: ...martLog Pro onto the turnstile s lid using the 2 slanted standoffs 1 socket head cap screw and 1 internal tooth lock washer See Figure 2 NOTE This mounting is also sold separately as EMIT item 50783 I...

Page 3: ...in front of the RFID icon for a full second if using proximity badges See Figure 5 3 Follow the prompt on the SmartLog s display 4 When performing a footwear test be sure to place both feet on the du...

Page 4: ...aking a short walk to build a sweat layer for better conductivity Figure 7 Performing a single wire wrist strap test Figure 6 Performing a footwear test 7 Pass through the turnstile The turnstile will...

Page 5: ...0A Cable Length 5 ft 1 5 m Turnstile Input Voltage and Frequency 110VAC 50 60 Hz 50781 220VAC 50 60 Hz 50782 Operating Temperature 70 F to 85 F 21 C to 30 C for 1 gigohm test limit 41 F to 85 F 5 C t...

Page 6: ...INDUSTRIES INC Employee Owned EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com Figure 10 Dimensions of the EMIT SmartLog Pro with Turnstile 27 0 69 cm 9 5 24 cm 25 0 64 cm 40...

Page 7: ...980 Website DescoEMIT com Figure 11 Turnstile lid cutout dimensions for mounting the SmartLog Pro using the 50783 Turnstile Mounting Kit all dimensions are in inches Limited Warranty Warranty Exclusio...

Reviews: