4. Spray Application
TIP:
IF THE APPLICATOR BECOMES WET OR BEGINS
TO DRIP, YOU ARE MOVING TOO SLOW OVER THE
SURFACE TARGET AREA AND NEED TO SPEED UP THE
APPLICATION PROCESS. DO NOT OVER-SATURATE
THE SURFACE. IF YOU SEE RUNS OR PUDDLES YOU
ARE APPLYING TOO MUCH CHEMICAL. THE GOAL
IS TO ACHIEVE EVEN COVERAGE OVER THE TARGET
SURFACE AREA.
The system is designed for single or multiple application
environments. Please use the multiple tank applications
carefully by marking tanks with your chemical identifiers
when necessary.
Application Tips:
While depressing the trigger button, move the
applicator in an “S” pattern from bottom to the top
of the surface target area in a continuous motion.
Stay in motion, electrostatically charged droplets will
accumulate in higher levels at the tip of the applicator
if you move too slowly while the device is in use.
Do not over apply.
In between chemical changes, press the trigger while
pointing to the floor or other safe target area for four
to five seconds to clear the remaining chemical in the
system.
1.
2.
3.
4.
The system’s battery use is controlled to draw down the
battery to 20% of available cell power and to then shut off.
This will eliminate the possibility of unwanted battery
damage and extend the life of the battery.
Tips:
Fully charge each battery before use.
Keep connectors clean and dry at all times.
Insert with battery tab to the left and the battery meter
facing outwards.
Do not expose batteries to standing liquid.
1.
2.
3.
4.
Begin at the farthest point from the doorway, work
back toward the doorway so you can step out when
application is complete.
Aim applicator 3 feet (optimal distance) from the
surface target area, begin with a smooth figure “S”
movement aiming below, at, and above the surface
target area while walking at an average pace
(continuously moving).
Make sure you are working in a methodical “S” pattern
and let your passes overlap when moving to the next
surface target area.
Allow treated area to set for contact time as
recommended by the chemical manufacturer’s
label before re-entry into the area.
1.
2.
3.
4.
B. Spray Application Process:
C. Fluid Management:
Make sure food and drinks are removed or covered
before application.
Spotless, clean interiors require no prep work prior to
application.
Loose debris must be swept from floors and other
surfaces prior to application.
Inspect the area for mechanical barriers such as:
magazines on table tops, chairs touching each other,
a table or a wall. The intended target surface area for
application will need to be accessible.
Please cover and remove valuables. Electronics,
furniture, paper or other common necessities do not
need to be removed from the area.
Once the area has been cleaned, application can
begin.
This system in NOT a mechanical cleaner.
1.
2.
3.
4.
5.
6.
7.
A. Preparing the Spray Area:
D. Battery Management: