Hold down 4s: 

Turn on/turn off the control

functions when P21 is activated

Pressed together: 

Turn on Function blocking

if P20 is activated

Pressed simultaneously: 

Clears temperature

logs (Cr9)

Hold down 3s: 

Adjust the Setpoint

Quick touch: 

Current process display

Continuously pressed when turning on the
control: 

Disables locked mode (if enabled)

Quick touch: 

Maximum and minimum

temperatures display (record)

Pressed simultaneously: 

Access to complete

parameters menu

Press for 5s: 

Turn on defrost mode

 

+

 

 


TABLE 3

PAR

Cr9

rE9

Prc

Loc
CtL

dFr
SEt

Function Selection
Clear Min|Max
Min|Max recorded
Show current Process
Functions Blocking
Control Functions Shutdown
Manually Defrost

Setpoint Adjustment

FUNCTION

DESCRIPTION

TABLE 2

07

USER 

MANUAL

TEMPERATURE CONTROLLER

STORM 

ST

101 

2HP

3. EASY MENU FEATURES

By pressing      and then      the following 

sequence will be shown

       

[PAR]       [Cr9]      [rE9]      [Prc]      [Loc]

        [CtL]      [ dFr]      [SEt]

 To access the function, press   

Description of functions:

▶ PPress      and then      until 

[dFr]

 is shown. Press      and 

[On] 

and      will be shown.

▶ The defrost could be activated or disactivated by pressing      

until 

[On]

 be shown and      is off.

With  the  functions  blocked,  it  will  only  be 

possible to view the parameters. In an attempt to 

change the parameters, 

[Loc]

  will  be  displayed.

      indicates that this function is activated.

This function requires that parameter 

P20

 have 

a value greater than 15. If 

P20

 have the value 

[no]

the blocking function will not be activated.

4. QUICK ACCESS KEY MAP

When the controller is displaying the 

temperature, the key combinations below are 
shortcuts to the functions:

3.1. MANUAL DEFROST CYCLE

(FORCED DEFROST)

3.2. FUNCTIONS LOCKDWON

▶ 

Press      and then      until 

[Loc]

 be shown. Press      and 

[OFF] 

will be shown.

▶ Press      during the time that was setted in P20. 

[On]

 will be 

shown.

This function disables the control functions. 

ST101 2HP starts to operate as a temperature 

display. This function depends on the 

parameters configured in 

P21

.

▶ Press      and then      until 

[Ctl]

 be shown. Press      and 

[OFF] 

and       will be shown.

Note:

 This function could be activated or disactivated by 

pressing      . 

[On]

 and       will be shown.

3.3. CONTROL FUNCTIONS SHUTDOWN

Summary of Contents for STORM ST101 2HP

Page 1: ...T101 2HP HEATING OR COOLING WITH NATURAL DEFROST THROUGH COMPRESSOR SHUTDOWN FRONT PANEL IP65 PROGRAMABLE BY NFC APP EVEN UNPLUGGED SHORTCUT KEY EASY TO PROGRAM POWERFUL 2HP RELAY AUTOMATIC BIVOLT 85...

Page 2: ...2 3 Con guration With Frontal Keys 2 3 1 Adjustment Of The Setpoint Temperature 2 3 2 Advanced Operations Access The Full Menu 3 Easy Menu Features 3 1 Manual Defrost Cycle Forced Defrost 3 2 Functio...

Page 3: ...FC communication and active internet plan for sharing settings if applicable 1 1 APPLICATIONS The ST101 2HP Temperature Controller it s compatible with applications that requires ON 0FF control and te...

Page 4: ...in a space as indicated in the table of item 1 3 Avoid installing in places exposed to high humidity and dirt that can cause condensation and the introduction of substances or particles Make sure that...

Page 5: ...wer Parameters from P02 to P24 Edit the parameters Compare Compare two settings and list their differences Send NFC Send the parameters from P02 to P24 to the controller even if disconnected from the...

Page 6: ...ustments For example Shows that parameters P02 P06 and P07 are different Get the phone closer to the controller to send the con guration Even when disconnected from the power Con guration successfully...

Page 7: ...s PPress and then until dFr is shown Press and On and will be shown The defrost could be activated or disactivated by pressing until On be shown and is off With the functions blocked it will only be p...

Page 8: ...mperature Setpoint It is the value set for temperature control where the load supply output is turned off 50 4 200 C Standard value Minimum Maximum Unid Operating mode Heating Cooling P03 Indication s...

Page 9: ...will perform the defrost when the controller is energized Note The defrost time will be in accordance with parameter P11 0 refri 0 refri 1 Degg Standard value Minimum Maximum Operating mode Cooling P...

Page 10: ...ocking time This function activates the permission to block or not the functions through the Easy Key Check item 3 3 on how to activate deactivate the block Option No It does not allow the Loc functio...

Page 11: ...the NFC communication from the controller No NFC Communication between cell phone and Controller enabled Yes NFC communication blocked The cell phone will not communicate with the controller Note This...

Page 12: ...oduct and is exempt from any extra expenses such as supplies services or transportation 8 WARRANTY Still have any questions Contact us e mail marketing emicol com br 9 CUSTOMER SERVICE 12 I S O 9001 2...

Reviews: