05

Receive NFC

Receives configuration from 

the Controller even when 

disconnected from the power.

New configuration

Create configuration and edit 

parameters from P02 to P24.

Move the phone closer to the 

controller to receive the 

configuration. Even when 

disconnected from the power.

Parameters f rom P02 to P24

Edit the parameters.

Compare

Compare two settings and list 

their differences.

Send NFC

Send the parameters f rom 

P02 to P24 to the controller, 

even if disconnected f rom the 

power.

Share

Share the parameters f rom 

P02 to P24. For example, by 

WhatsApp.

Delete

Delete the programs f rom 

the phone's memory (cannot 

be undone).

USER 

MANUAL

TEMPERATURE CONTROLLER

STORM 

ST

101 

2HP

2.2. EXAMPLES OF EMICOL EASY APP SCREENS

Get the phone

closer to the

Controller!

Summary of Contents for STORM ST101 2HP

Page 1: ...T101 2HP HEATING OR COOLING WITH NATURAL DEFROST THROUGH COMPRESSOR SHUTDOWN FRONT PANEL IP65 PROGRAMABLE BY NFC APP EVEN UNPLUGGED SHORTCUT KEY EASY TO PROGRAM POWERFUL 2HP RELAY AUTOMATIC BIVOLT 85...

Page 2: ...2 3 Con guration With Frontal Keys 2 3 1 Adjustment Of The Setpoint Temperature 2 3 2 Advanced Operations Access The Full Menu 3 Easy Menu Features 3 1 Manual Defrost Cycle Forced Defrost 3 2 Functio...

Page 3: ...FC communication and active internet plan for sharing settings if applicable 1 1 APPLICATIONS The ST101 2HP Temperature Controller it s compatible with applications that requires ON 0FF control and te...

Page 4: ...in a space as indicated in the table of item 1 3 Avoid installing in places exposed to high humidity and dirt that can cause condensation and the introduction of substances or particles Make sure that...

Page 5: ...wer Parameters from P02 to P24 Edit the parameters Compare Compare two settings and list their differences Send NFC Send the parameters from P02 to P24 to the controller even if disconnected from the...

Page 6: ...ustments For example Shows that parameters P02 P06 and P07 are different Get the phone closer to the controller to send the con guration Even when disconnected from the power Con guration successfully...

Page 7: ...s PPress and then until dFr is shown Press and On and will be shown The defrost could be activated or disactivated by pressing until On be shown and is off With the functions blocked it will only be p...

Page 8: ...mperature Setpoint It is the value set for temperature control where the load supply output is turned off 50 4 200 C Standard value Minimum Maximum Unid Operating mode Heating Cooling P03 Indication s...

Page 9: ...will perform the defrost when the controller is energized Note The defrost time will be in accordance with parameter P11 0 refri 0 refri 1 Degg Standard value Minimum Maximum Operating mode Cooling P...

Page 10: ...ocking time This function activates the permission to block or not the functions through the Easy Key Check item 3 3 on how to activate deactivate the block Option No It does not allow the Loc functio...

Page 11: ...the NFC communication from the controller No NFC Communication between cell phone and Controller enabled Yes NFC communication blocked The cell phone will not communicate with the controller Note This...

Page 12: ...oduct and is exempt from any extra expenses such as supplies services or transportation 8 WARRANTY Still have any questions Contact us e mail marketing emicol com br 9 CUSTOMER SERVICE 12 I S O 9001 2...

Reviews: