3. Operation and Display
EM-GU User’s Manual
12
Range: 0%~150.0% (Default: 20.0%)
Description: Analog output lower setting, default 4mA.
F38
4-20mA Upper Calibration
Range: 0%~150.0% (Default: 100.0%)
Description: Analog output upper setting, default 20mA.
F39
Running Over Load(OL)
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F40
Starting Over Current(OC)
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F41
Running Over Current(OC)
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F42
Over Voltage
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F43
Under Voltage
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F44
Current Unbalance
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F45
Under Load
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F46
Over Heat
Range: 0~1 (Default: 0)
Option: 0: Alarm & Stop
1: Ignore (The protection function is disabled)
F47
Language
Range: 0~1 (Default: 1)
Option: 0:English
1:
中文
Select the language in which messages and feedback are displayed on the keypad.
F48
MB Soft Version
Description: Displays the master board software version information. This parameter is read only and
cannot be modified.