22
English
CODE
POSSIBLE CAUSE
POSSIBLE SOLUTION
16
Loose pulley
Tighten pulley set screw, torque to 145–165 in.-lbs.
(16.4– 19.6 Nm).
17
Loose flywheel
Tighten flywheel screw, torque to 15–18 ft.-lbs.
(20.3– 24.4 Nm).
18
Carbon build-up in pump
Contact an EMGLO factory service center or an EMGLO
authorized service center.
19
Belt to tight
Check belt tension, see
Adjusting Belt Tension
under
Maintenance.
20
Pulley misalignment
See
Motor Pulley/Flywheel Alignment
under
Maintenance
.
21
Extension cord is wrong length or gauge
Check for proper gauge wire and cord length. See
Extension Cords
under
Installation
.
22
Loose electrical connections
Contact an EMGLO factory service center or an EMGLO
authorized service center.
23
Pump oil is low
Add EMGLO Synthetic Blue compressor oil to pump. See
Compressor Pump Oil
under
Maintenance.
24
Regulator is not adjusted correctly for accessory being
used
It is normal for some pressure drop to occur when an acces-
sory is used, adjust the regulator as instructed in
Regulator
under
Features
if pressure drop is excessive.
NOTE:
Adjust the regulated pressure under flow conditions
while accessory is being used.
25
Damaged regulator
Replace.
26
Detergent type oil being used in pump
Drain oil and refill pump with EMGLO Synthetic Blue
compressor oil.