7
Notes on operation
7.3
Operating modes
58
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
7.2.2
Order parameters
Check whether the EdEx thrusters used comply with all safety-
relevant parameters (e.g. thruster category, surface temperature)
Check whether the documentation is complete and
comprehensive (e.g. approvals, conditions, certificates, tests to
be carried out)
7.2.3
Technical parameters
Check the screw connections of the connection, protective
conductor and equipotential bonding terminals for tightness
Check the screw connections of the housing cover for tightness
Check the torque of the cable entry
Check the tightness between cable and cable gland seal
Check whether the EdEx thruster is ready for operation
7.3
Operating modes
Continuous operation S1 and switching operation S3 with
maximum 240 c/h, up to 60 % duty cycle
Summary of Contents for ELDRO EdEx 125/160