3
Technical data
3.5
Characteristics
26
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
3.5
Characteristics
3.5.1
Short lift thrusters
General characteristics
All technical data are mean values relating to +20 °C thruster
temperature.
Table 6:
Characteristics – short lift thrusters EdEx 32/50-EdEx 150/75
EdEx type
EdEx
32/50
50/50
80/60
80/75
125/60
125/60
125/75
150/60
150/75
Nominal actuating force [N]
320
500
800
800
1,250
1,250
1,250
1,500
1,500
Nominal lift [mm]
50
50
60
75
60
60
75
60
75
Power consumption
2) 3)
[W]
150
180
220
220
250
250
250
360
360
Current at 400 V AC 3-ph
2) 3)
[A]
0.30
0.38
0.48
0.48
0.52
0.52
0.52
0.63
0.63
Fill quantity [l]
2.4
2.4
3.9
3.9
3.9
3.9
3.9
3.9
3.9
Weight [kg]
32.0
32.0
45.0
45.0
45.0
45.0
45.0
20.6
20.6
Table 7:
Characteristics – short lift thrusters EdEx 200/60-EdEx 320/100
EdEx type
EdEx
200/60
250/60
320/100
Nominal actuating force [N]
2,000
2,500
3,200
Nominal lift [mm]
60
60
100
Power consumption
2) 3)
[W]
320
360
550
Current at 400 V AC 3-ph
2) 3)
[A]
0.64
0.69
0.90
Fill quantity [l]
7.4
7.4
10.8
Weight [kg]
65.0
65.0
80.0
1)
Values for thrusters with integrated brake/reset spring
2)
Values at operating temperature; with switch-on processes below 0 °C thruster temperature the current consumption is
approx. 2 times the current consumption at a thruster temperature > +20 °C
3)
Hydrotherm 46 M