3
Technical data
3.5
Characteristics
30
/ 75
ELDRO-EdEx-Montageanleitung-607338-EN.docx
3.5.3
Setting times
The following table contains time data, the lowering and resetting
movement, determined for EdEx lifting thrusters without built-in
lowering valve with constant nominal weight loads at +20 °C thruster
temperature.
Table 15:
Time data of the lowering and resetting movement
EdEx type
Without lowering valve
With integrated lowering valve
Lowering time
Adjustable lowering time
in [s]
min. in [s]
max. in [s]
EdEx 32/50…
0.45
For data refer to delivery documents, consult with EMG
Automation GmbH if necessary
EdEx 50/50…
0.36
EdEx 80/60…
0.48
EdEx 80/75…
0.62
EdEx 125/60…
0.36
EdEx 125/75…
0.49
EdEx 150/60…
0.34
EdEx 150/75…
0.44
EdEx 200/60…
0.40
EdEx 250/60…
0.35
EdEx 320/100…
0.60
EdEx 80/160…
0.90
For data refer to delivery documents, consult with EMG
Automation GmbH if necessary
EdEx 125/160…
0.70
EdEx 150/160…
0.65
EdEx 200/160…
0.85
EdEx 250/160…
0.80
EdEx 320/160…
0.62
Detailed data for the adjustable delays for installed lowering valves
must be determined by the manufacturer
EMG Automation GmbH
through individual tests. This requires precise information regarding
the operating conditions.
Summary of Contents for ELDRO EdEx 125/160
Page 2: ......