See below for definitions of the wiring terminals on the sub-base of the thermostat.

 

 

Wiring Terminals

Sensi

TM

 Wi-Fi Programmable Thermostat  

|

  MANUAL OPERATION 

 

7

TERMINAL OUTPUTS AND WIRING DIAGRAMS

* If the old thermostat has separate RC and RH wires coming out of the wall, clip  

the RC/RH jumper on the back of the thermostat above the battery compartment.

 

**The common wire could be labeled “C” on your old thermostat, or it could be  

labeled “B” or “X.” Please refer to the owner’s manual of your old thermostat  

for clarification.

 

 

DOES WIRE COLOR CORRESPOND TO THE THERMOSTAT TERMINALS?

Wire color does not always correspond to the thermostat letters. A white wire may be 

attached to the “W” terminal on the old thermostat, or it may be attached to a different 

terminal with a different letter. Be sure to take a photo of the old thermostat that shows the 

wire colors and terminal letters before labeling and removing any wires.

RH*

 

Power for heating, 24V

 

RC*

 

Power for cooling, 24V

 

C**

 

Common wire, 24V

 

Y

 

First outdoor stage cooling on conventional systems or first heat and cool on heat pump systems.

 

 

Second outdoor stage cooling on conventional systems or second heat and cool on two stage 

heat pump systems.

 

 

First indoor stage heat on conventional systems or first stage auxiliary/emergency heat on 

heat pump systems.

 

 

Second indoor stage heat on conventional systems or second stage auxiliary/emergency heat 

on heat pump systems.

 

 

 

 

Y2

 

W/E

 

W2

 

G

 

Indoor blower (fan)

 

O/B

 

Changeover (reversing valve) connection for heat pump or zone  panel systems

 

L

 

Heat Pump system, “L” wire connection.

 

 

 

Terminal Label

Definition

Summary of Contents for Sensi UP500W

Page 1: ...SensiTM Wi Fi Programmable Thermostat MANUAL OPERATION Version March 2016 2016 Emerson Electric Co All rights reserved ...

Page 2: ... OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual Settings 5 Menu Configurations 6 Wiring Terminals 7 Back of the Face Plate 8 Contents SensiTM Wi Fi Programmable Thermostat MANUAL OPERATION 2 ...

Page 3: ...tem mode between Heat Cool Off or Aux Auto Mode is only available using the Sensi app FAN BUTTON Switches fan mode from Auto or On Leave the fan mode on Auto to allow the thermostat to control the fan as necessary SCHEDULE BUTTON Toggles the schedule On or Off The thermostat runs a program based on time and temperature set points when Schedule is On UP ARROW BUTTON Adjusts the temperature set poin...

Page 4: ...he up and down arrow buttons TEMPORARY HOLD When your schedule is set to On your Sensi thermostat controls your home based on the time and temperature settings in the current schedule To temporarily change your temperature use the up and down arrows in the app or on the thermostat Your Sensi thermostat will display Temporarily Set To on the thermostat and will hold your new temperature until the n...

Page 5: ... Heat or Cool 3 Press and hold the Schedule button until you see the time flash at the top of the screen a Adjust the time on the thermostat if needed using the up and down arrow buttons 4 Press Next 5 You will see a large number in the middle of the screen This refers to your set point a The time will be flashing at the top of the screen Adjust the time of the first set point using the up and dow...

Page 6: ...age HP2 Heat Pump 2 Two Stage AC0 No Cooling GA1 Gas 1 Single Stage GA2 Gas 2 Two Stage EL1 Electric 1 Single Stage EL2 Electric 2 Two Stage FAN Fan No Heat O o Energize in Cool B b Energize in Heat Z 2 Zone valve setting On Off Wireless Setup Connects Thermostat to Wi Fi network Fahrenheit or Celsius Outdoor Equipment Configuration Configuration for the outdoor equipment either heat pump or conve...

Page 7: ...the old thermostat or it may be attached to a different terminal with a different letter Be sure to take a photo of the old thermostat that shows the wire colors and terminal letters before labeling and removing any wires RH Power for heating 24V RC Power for cooling 24V C Common wire 24V Y First outdoor stage cooling on conventional systems or first heat and cool on heat pump systems Second outdo...

Page 8: ...your thermostat was manufactured RC RH INTERNAL JUMPER WIRE Only clip this if you have separate RC and RH transformers coming out of the wall BATTERY COMPARTMENT Two AA Alkaline batteries are used for back up purposes When you see the battery indicator bar on the thermostat display reach 3 bars replace these batteries to maintain Wi Fi connectivity MODEL NUMBER Illustrates whether you purchased th...

Reviews: