Quick Installation Guide
00825-0100-4662, Rev CC
December 2012
Rosemount 8732
27
Table 11. Handheld Fast Keys (HART Handheld Communicator)
Local Operator Interface
To activate the optional Local Operator Interface (LOI), press the DOWN arrow two times.
Use the UP, DOWN, LEFT, and RIGHT arrows to navigate the menu structure. A map of the
LOI menu structure is shown on page 28. The display can be locked to prevent unintentional
configuration changes. The display lock can be activated through a HART communication
device, or by holding the UP arrow for 10 seconds. When the display lock is activated, DL
will appear in the lower right hand corner of the display. To deactivate the display lock (DL),
hold the UP arrow for 10 seconds. Once deactivated, the DL will no longer appear in the
lower right hand corner of the display.
Function
HART Fast Keys
Process Variables
1, 1
Primary Variable (PV)
1, 1, 1
PV Percent of Range
1, 1, 2
PV Analog Output (AO)
1, 1, 3
Totalizer Set-Up
1, 1, 4
Totalizer Units
1, 1, 4, 1
Gross Total
1,1,4,2
Net Total
1,1,4,3
Reverse Total
1,1,4,4
Start Totalizer
1,1,4,5
Stop Totalizer
1,1,4,6
Reset Totalizer
1,1,4,7
Pulse Output
1,1,5
Basic Setup
1,3
Tag
1,3,1
Flow Units
1,3,2
PV Units
1,3,2,1
Special Units
1,3,2,2
Volume Unit
1,3,2,2,1
Base Volume Unit
1,3,2,2,2
Conversion Number
1,3,2,2,3
Base Time Unit
1,3,2,2,4
Flow Rate Unit
1,3,2,2,5
Line Size
1,3,3
PV Upper Range Value (URV)
1,3,4
PV Lower Range Value (LRV)
1,3,5
Calibration Number
1,3,6
PV Damping
1,3,7
Review
1,5