Quick Installation Guide
00825-0100-4662, Rev CC
December 2012
Rosemount 8732
30
North American Certifications
Factory Mutual (FM)
N0
Non-incendive for Class I, Division 2
Groups A, B, C, and D non-flammable fluids
(T4 at 60 °C: -50 °C
Ta
+60 °C)
Dust-ignition proof Class II/III, Division 1
Groups E, F, and G (T5 at 60 °C)
Hazardous Locations; Enclosure Type 4X
N5
Non-incendive for Class I, Division 2,
Groups A, B, C, and D flammable fluids
(T4 at 60 °C: -50 °C
Ta
+60 °C)
Dust-ignition proof Class II/III, Division 1
Groups E, F, and G (T5 at 60 °C)
Hazardous Locations; Enclosure Type 4X
Requires sensors with N5 Approval
E5
Explosion proof for Class I, Division 1
Groups C and D (T6 at 60 °C)
Dust-ignition proof Class II/III, Division 1
Groups E, F, and G (T5 at 60 °C),
Non-incendive for Class I, Division 2
Groups A, B, C, and D flammable fluids
(T4 at 60 °C: -50 °C
Ta
+60 °C)
Hazardous Locations; Enclosure Type 4X
Canadian Standards Association (CSA)
N0
Non-incendive for Class I, Division 2
Groups A, B, C, and D non-flammable fluids
(T4 at 60 °C: -50 °C
Ta
+60 °C)
Dust-ignition proof Class II/III, Division 1
Groups E, F, and G (T4 at 60 °C)
Hazardous Locations; Enclosure Type 4X
European Certifications
E1 ATEX Flameproof
Certificate No: KEMA 07ATEX0073 X
II 2G Ex de IIC T6 or
II 2G Ex de [ia] IIC T6
without LOI (-50 °C
Ta
+60 °C)
with LOI (-20 °C
Ta
+60 °C)
V
max
= 250 V AC or 42 V DC
0575
4662RevCCQIG.fm Page 30 Thursday, January 10, 2013 5:11 PM